Petr Krejčí

ORCID: 0000-0002-0593-9602
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Power Quality and Harmonics
  • Renewable energy and sustainable power systems
  • Animal Nutrition and Physiology
  • Meat and Animal Product Quality
  • Growth Hormone and Insulin-like Growth Factors
  • Reproductive Physiology in Livestock
  • Transportation Systems and Safety
  • Effects of Environmental Stressors on Livestock
  • Transport and Logistics Innovations
  • Animal Behavior and Welfare Studies
  • Ruminant Nutrition and Digestive Physiology
  • Advanced Battery Technologies Research
  • Agriculture and Biological Studies
  • Non-Destructive Testing Techniques
  • Mining and Industrial Processes
  • Power System Reliability and Maintenance
  • Agriculture Sustainability and Environmental Impact
  • Photovoltaic System Optimization Techniques
  • Power System Optimization and Stability
  • Regulation of Appetite and Obesity
  • Parathyroid Disorders and Treatments
  • Thermal Analysis in Power Transmission
  • Law, logistics, and international trade
  • Genetic Syndromes and Imprinting
  • Plant Toxicity and Pharmacological Properties

VSB - Technical University of Ostrava
2011-2024

Brno University of Technology
2022

University of Ostrava
2007-2013

Czech Academy of Sciences, Institute of Animal Physiology and Genetics
1973-2002

Czech Academy of Sciences
2002

Kielanowski Institute of Animal Physiology and Nutrition
2001

Polish Academy of Sciences
2001

Institute of Animal Physiology of the Slovak Academy of Sciences
1992

Veterinary Research Institute
1984-1989

Czech Academy of Sciences, Institute of Physiology
1976

Alzheimer’s disease (AD) is a deadly cognitive condition in which people develop severe dementia symptoms. Neurologists commonly use series of physical and mental tests to diagnose AD that may not always be effective. Damage brain cells the most significant change AD. Proper analysis images assist identification crucial bio-markers for disease. Because development so intricate, traditional image processing algorithms sometimes fail perceive important bio-markers. The deep neural network...

10.3390/electronics12030676 article EN Electronics 2023-01-29

Three-month old Polish Lowland female lambs were fed isocaloric diets containing 14.2% (standard) or 8.1% of proteins for twenty weeks. Changes in body weight characteristic normal growth performance all animals, but daily gain calculated the whole experimental period was significantly lower a low protein diet (87.9 +/- 13.5 and 158 13.8 g/day, respectively). Two series blood collections (4 hrs with 15 min interval) performed at age 21 26 weeks order to analyze hormone (GH) concentration...

10.1055/s-0029-1211423 article EN Experimental and Clinical Endocrinology & Diabetes 2009-07-15

Effects of infusions neuropeptide Y (NPY) into 3rd ventricle growing sheep fed on diets containing restricted (R) or elevated (E) levels protein the immunoreactive (ir) somatostatin neurones, ir somatotrophs, growth hormone (GH) concentration in blood plasma were studied. The long-term restriction diet elicited: enhancing irSS content periventricular perikarya; diminishing stores median eminence and elevating number somatotrophs irGH. NPY enhanced perikarya E diminished irGH R diet. as well...

10.55782/ane-2001-1401 article EN cc-by Acta Neurobiologiae Experimentalis 2001-12-31

This paper presents load flow analysis and the mathematical steady-state modeling of Static Synchronous Compensator (STATCOM) to study its effect on power system network.More precisely, we propose a new approach method so-called direct algorithm then compare it with indirect in testing cases: IEEE 5-bus, 14-bus, 30-bus systems.We accuracy, number iterations computational time.The simulation results show that is effective terms speed computation various practical applications.

10.15598/aeee.v17i1.3054 article EN cc-by Advances in Electrical and Electronic Engineering 2019-03-27

Abstract Hardwood species are becoming increasingly important with the growing need for a diversity of forests that have recently been facing global temperature changes or conifer pests. This further leads to growth its potential as building material may originate from sustainable production. As hardwoods be properly processed, article deals disintegration European beech. The influence wood grain direction, uncut chip thickness and cutting speed on force magnitudes was experimentally...

10.1007/s00226-022-01442-6 article EN cc-by Wood Science and Technology 2022-12-16

In the power company CEZ in North Moravia Region (the Czech Republic) monitoring of a number selected parameters quality electrical energy (harmonics, flicker and unbalance) is being carried out cooperation with research laboratories Faculty Electrical Engineering Computer Science, VSB - Technical University Ostrava. The complex manner 59 feeding points 400 V, always within one week intervals, at same time on all voltage levels (HV, MV LV). whole cycle lasted for 3 years, currently fourth...

10.1109/ichqp.2008.4668753 article EN 2008-09-01

Standard EN 50160 ED. 3 was released in 2011 and despite the fact that this is third edition of standard, it still does not limit values for all parameters at voltage levels. This article examines various methods evaluation variables with two levels then presents some recommendations amendments undefined vvn network 3rd.

10.1109/epe.2015.7161205 article EN 2015-05-01

The energy independence, reliability and safety of distribution system operation as well use renewable resources have been hot research topics in recent years. This leads to the development active grids with specific requirements. Power Quality problems can arise when using sources grids. Problems are caused by decreased short-circuit power local sources, stochastic supply electric from operating grid off-grid regime without connection external system. In case these conditions, mutual...

10.26552/com.c.2015.1a.71-76 article EN cc-by Communications - Scientific letters of the University of Zilina 2015-04-30

In the power company CEZ in North Moravia Region (the Czech Republic) monitoring of a number selected parameters quality electrical energy (harmonics, flicker and unbalance) is being carried out cooperation with research laboratories Faculty Electrical Engineering Computer Science, VSB - Technical University Ostrava. The complex manner 59 feeding points 400 V, always within one week intervals, at same time on all voltage levels (HV, MV LV). paper, results during 12 years will be summarized...

10.1109/epqu.2011.6128950 article EN 2011-10-01

High-quality supply of electricity is one the most important part transmission to customers. For distribution companies are responsible face any complaints about quality electrical energy. All such must examine and then determine what type claim it is. Verifying legitimacy claims power monitoring carried out parameters according ČSN EN 50160th. justification complaint on take measures that would remove cause quality.

10.1109/eeeic-2.2013.6737892 article EN 2013-11-01

In the power company ČEZ in North Moravia region monitoring of a number selected parameters quality electrical energy (harmonics, flicker and unbalance) is being done cooperation with research laboratories Faculty Electrical Engineering Computer Science, VŠB - Technical University Ostrava. The complex way 59 feeding points 400 V, always one week intervals, at same time on all voltage levels (HV, MV LV). whole cycle lasted for 3 years, currently fourth realized. full cycles enables comparing...

10.1109/epqu.2007.4424143 article EN 2007-10-01

This study describes the impact of operation big customers on voltage quality (VQ) parameters in medium-voltage (MV) distribution grids. The survey is based evaluation 45 VQ measurements which were carried out 15 different delivery points other customers. These made years 2014, 2015 and 2016 (15 a year) evaluated according to standard EN 50160. variations was analysed.

10.1049/oap-cired.2017.0148 article EN CIRED - Open Access Proceedings Journal 2017-10-01

In 1997 cooperation began between the Faculty of Electrical Engineering and Computer Science power company CEZ on a joint project that involved monitoring selected voltage quality parameters. Over course several years measurements were carried out at 59 points distribution system low (LV) level their supply nodes medium (MV) high (HV) levels, which constituted more than 100 measured points. The continued until 2012 (with one-year break in 2009) with total scope five cycles three-year...

10.1109/eeeic.2016.7555818 article EN 2016-06-01

This paper focuses on the pivotal role of Harmonic Filters (HFs) in mitigating harmonic distortion within electrical systems to enhance power quality and efficiency. distortion, characterized by deviations from ideal sinusoidal waveform power, can cause equipment malfunctions, overheating, a reduced lifespan infrastructure. HFs, known for their cost-effectiveness simplicity, employ inductors, capacitors, resistors selectively reduce specific frequencies, thereby improving system reliability...

10.1109/epe61521.2024.10559509 article EN 2024-05-15

Electric power is the electrical appliances basic means for their functionality. In case that energy customer causes problems arise thereby complaints quality. areas with frequent of quality measurements were made in order to resolve reported and also investigate cause exceeding compatibility level

10.1109/epe.2017.7967253 article EN 2017-05-01

This article briefly summarizes the issue of photovoltaic panels from point their failure rate and occurrence degradation processes. The individual chapters outline methods diagnostics panel defects possible solutions.

10.1109/epe54603.2022.9814146 article EN 2022-06-08
Coming Soon ...