Volkan Arısan

ORCID: 0000-0002-0881-7483
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Dental Implant Techniques and Outcomes
  • Bone Tissue Engineering Materials
  • Dental Radiography and Imaging
  • Dental materials and restorations
  • Orthodontics and Dentofacial Orthopedics
  • Orthopaedic implants and arthroplasty
  • Periodontal Regeneration and Treatments
  • Oral microbiology and periodontitis research
  • Endodontics and Root Canal Treatments
  • Laser Applications in Dentistry and Medicine
  • Anatomy and Medical Technology
  • Dental Trauma and Treatments
  • Oral and gingival health research
  • Electrospun Nanofibers in Biomedical Applications
  • Shoulder and Clavicle Injuries
  • Pathogenesis and Treatment of Hiccups
  • Autoimmune and Inflammatory Disorders
  • Bone health and treatments
  • Dental Anxiety and Anesthesia Techniques
  • Cancer Diagnosis and Treatment
  • Oral and Maxillofacial Pathology
  • Reconstructive Surgery and Microvascular Techniques
  • Linguistics and Cultural Studies
  • Obstructive Sleep Apnea Research
  • Dental Health and Care Utilization

Istanbul University
2013-2025

Fatih University
2024-2025

Background: Stereolithographic surgical guides provide significant benefits during the simultaneous placement of multiple implants with regard to final prosthetic plan. However, deviation from planning poses a risk. Deviations that were placed by bone‐, tooth‐, and mucosa‐supported stereolithographic examined in this study. Methods: After enrolling 54 eligible patients, 294 planned on cone‐beam computerized tomography CB(CT)‐derived images. Sixty guides, both single‐ multiple‐type, produced...

10.1902/jop.2009.090348 article EN Journal of Periodontology 2010-01-01

The aim of this study was to compare the surgical and post-operative outcomes a computer-aided implant surgery performed by bone- mucosa-supported stereolithographic (SLA) guides against standard technique.Multiple- single-type SLA from two commercial manufacturers were produced total 341 implants placed 52 patients using technique (Control group), (bone-supported guide [BSG] group) (Flapless in 21, 16 15 patients, respectively. Surgical duration (min), number analgesics (tablets) as well...

10.1111/j.1600-0501.2010.01957.x article EN Clinical Oral Implants Research 2010-05-27

Abstract Objectives The aim of this split‐mouth randomized controlled clinical trial was to compare the deviations planned and placed implants by assistance a micron tracker‐based dynamic navigation device or freehand methods. Material methods A thermoplastic fiducial marker adapted on anterior teeth, cone‐beam computerized tomography used for imaging. minimum one implant each side posterior maxilla, method randomly surgical insertion. Deviations were measured matching planning data with...

10.1111/clr.13563 article EN Clinical Oral Implants Research 2019-12-12

Abstract Objectives: Narrow diameter implants (NDIs; >3.75 mm) are useful in replacement of missing incisor teeth and when the bucco‐lingual width edentulous crest is insufficient. The present study evaluated success survival rates, peri‐implant parameters, mechanical prosthetic post‐loading complications NDIs followed over a 10‐year period. Material methods: Three hundred sixteen were inserted into 139 patients restored with 120 prostheses. Clinical radiographic assessment data collected...

10.1111/j.1600-0501.2009.01840.x article EN Clinical Oral Implants Research 2010-02-09

The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values the primary stability parameters implants that were placed by stereolithographic surgical guides analyzed in this study.Eighteen edentulous jaws randomly scanned a (CT group) or CBCT scanner (CBCT radiographic was measured from planned implants. A total 108 placed, insertion torque value (ITV) resonance frequency analysis (RFA). Radiographic subjective bone quality...

10.1111/j.1708-8208.2011.00436.x article EN Clinical Implant Dentistry and Related Research 2012-01-17

In this radiographic and microbiologic split-mouth clinical trial, efficacy of a diode laser as an adjunct to conventional scaling in the nonsurgical treatment peri-implantitis was investigated.Eradication pathogenic bacteria infected sulcular epithelium presents significant challenge peri-implantitis.Ten patients (mean age, 55.1 years; SD, 11.4) with 48 two piece, rough-surface implants diagnosed were recruited (NCT02362854). addition debridement (control group), crevicular sulci...

10.1089/pho.2015.3956 article EN Photomedicine and Laser Surgery 2015-09-18

Background/Objectives: The aim of this retrospective study was to radiographically evaluate the endo-sinus bone gain (ESBG) following osseodensification procedures using CBCT and compare results more conventional sinus lifting techniques. Methods: A total 72 patients underwent crestal floor elevation were provided with 102 implants a sand-blasted acid-etched surface microthreads (Medentika® Microcone Implants, Hugelsheim, Germany). Patients divided into two groups; group (OD; n = 36)...

10.3390/jcm13082225 article EN Journal of Clinical Medicine 2024-04-11

Background: Maxillary sinus lifting procedure enables clinicians to place implant‐supported prostheses even in cases with very limited vertical bone height of the maxillary sinus. The aim this study was evaluate implant success regard effects membrane perforations that occurred during surgery. Methods: group consisted 91 patients (29 females and 54 males) edentulous posterior maxilla. Implant placement combined surgery performed, 259 implants were inserted. Sinus detected 12 sites. After...

10.1902/jop.2006.060102 article EN Journal of Periodontology 2006-11-30

Simultaneous insertion of multiple implants may exhibit suboptimal positions, especially in edentulous jaws considered for a fixed restoration. The aim this study was to compare the incidence and confounding factors implant positioning errors related use freehand computer-aided treatment methods.A total 353 were placed 54 patients with at least one jaw using methods involving 16 mucosa- 12 bone-supported single- multiple-type stereolithographic surgical guides. At stage prosthesis delivery,...

10.11607/jomi.2691 article EN The International Journal of Oral & Maxillofacial Implants 2013-01-01

10.26650/jarhs2025-1561954 article EN cc-by-nc Sağlık Bilimlerinde İleri Araştırmalar Dergisi / Journal of Advanced Research in Health Sciences 2025-01-24

The aim of this study was to analyze the marginal bone loss and survival implants in augmented sinus area via lateral window approach. effect membrane perforation as well splinting upper structure analyzed. Two hundred eighty-nine were placed areas with xenografts collagen membranes 101 patients. Clinical radiographic data obtained during recall visits. Marginal Bone Loss (MBL) Cumulative Survival Rate (CSR) evaluated. mean follow-up period 12.4 years (range: 12 182 months). During period,...

10.3390/jfb16020065 article EN cc-by Journal of Functional Biomaterials 2025-02-13

ABSTRACT Purpose: Deviations of implants that were placed by conventional computed tomography (CT)‐ or cone beam CT (CBCT)‐derived mucosa‐supported stereolithographic (SLA) surgical guides analyzed in this study. Materials and Methods: Eleven patients randomly scanned a multi‐slice (CT group) CBCT scanner (CBCT group). A total 108 planned on the software using SLA guides. new scan was obtained merged with planning data to identify deviations between implants. Results Mann‐Whitney U test...

10.1111/j.1708-8208.2011.00435.x article EN Clinical Implant Dentistry and Related Research 2012-01-11

Objectives: Chemical modification of the already proven sand-blasted and acid-etched (SLA) implant had increased its surface wettability consequent early-term osseointegration characteristics. The aim this clinical trial was to compare stability changes, success, survival, peri-implant parameters marginal bone loss (MBL) early-loaded standard modified sand-blasted, (modSLA) implants. Material methods: A total 96 SLA modSLA implants were placed in a bi-lateral, cross-arch position jaws 22...

10.1111/j.1600-0501.2010.02065.x article EN Clinical Oral Implants Research 2010-12-28

Objective: The aim of this pilot study was to compare the early-term osseointegration characteristics standard (SLA) and modified sand-blasted acid-etched (modSLA) implants in an experimental animal model. Material methods: A total 30 SLA modSLA were placed tibiae three sheep insertion torque value (ITV) resonance frequency analysis (RFA) measurements performed. RFA measurement repeated on 3 6 weeks healed after which animals sacrificed for histomorphometric analysis. Bone-to-implant contact...

10.1111/j.1600-0501.2010.01990.x article EN Clinical Oral Implants Research 2010-10-13

The absence of sufficient bone volume is the most relevant problem in implant dentistry. Grafting from exogenous sources may provide a limited gain but exhibits poor performance large defects. Autogenous block transfer (ABBT) mandibular symphysis and ramus has been used with varying rates success. aim this study was to compare efficacy symphysal ABBT for restoration lost horizontal alveolar anterior maxilla. Implants placed augmented areas were also evaluated.The maxillary deficits 32...

10.1186/s12903-016-0161-8 article EN cc-by BMC Oral Health 2016-01-26

Restoration of the lost bone volume is one most deliberate issues in dentistry. Sustained-release microspherical oxytocin hormone a poloxamer hydrogel scaffold combined with mixture β-tricalcium phosphate and hydroxyapatite (CP) may serve as suitable graft. The aim this study was to design test novel thermosensitive graft incorporating oxytocin-loaded poly(d, l-lactide-co-glycolide) (PLGA) sustained-release microspheres CP. Thermosensitive containing CP (HCP graft) prepared base hollow...

10.1002/jor.24607 article EN Journal of Orthopaedic Research® 2020-02-04

Objectives There is a lack of data regarding whether edentulous subjects should remove dentures during spirometric measurements or not. The purpose this study to determine influences complete on parameters in subjects. Materials and methods A total 46 denture wearers were included study. Respiratory functions the evaluated by tests that performed four different oral conditions: without ( WOD ), with dentures, lower only upper only. Forced vital capacity FVC peak expiratory flow, forced...

10.1111/j.1741-2358.2012.00687.x article EN Gerodontology 2012-06-07

Many people have life-long problems with their dentures, such as difficulties speaking and eating, loose denture, sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for functional esthetic advantages. This case report presents the fabrication maxillary hybrid by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

10.1155/2015/841745 article EN cc-by Case Reports in Dentistry 2015-01-01

Parathyroid hormone (PTH) enhances bone healing. Strontium ranelate (SR) is an antiresorptive agent that increases formation. Reports about combined effects of PTH and SR on local regeneration in osteoporotic subjects are limited. We aimed at investigating the efficacy for promoting new formation critical-sized defects ovariectomized rats.Parathyroid hormone- and/or SR-containing poloxamer implant tablets with/without chitosan microparticles were delivered locally to calvarial 90 Wistar...

10.1111/odi.12895 article EN Oral Diseases 2018-05-18
Coming Soon ...