Sühan Tomaç

ORCID: 0000-0002-1830-7807
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Ophthalmology and Eye Disorders
  • Ophthalmology and Visual Impairment Studies
  • Glaucoma and retinal disorders
  • Visual perception and processing mechanisms
  • Botulinum Toxin and Related Neurological Disorders
  • Hallucinations in medical conditions
  • Intraocular Surgery and Lenses
  • Cerebral Venous Sinus Thrombosis
  • Corneal surgery and disorders
  • Cardiovascular Function and Risk Factors
  • Cardiovascular Health and Disease Prevention
  • Gastrointestinal disorders and treatments
  • Ophthalmology and Visual Health Research
  • Sympathectomy and Hyperhidrosis Treatments
  • Molecular Biology Techniques and Applications
  • Nasal Surgery and Airway Studies
  • Drug-Induced Ocular Toxicity
  • Sexual function and dysfunction studies
  • Sinusitis and nasal conditions
  • Restraint-Related Deaths
  • Neuroscience and Neuropharmacology Research
  • Psychosomatic Disorders and Their Treatments
  • Brucella: diagnosis, epidemiology, treatment
  • Head and Neck Surgical Oncology
  • Hormonal and reproductive studies

Aksaray University
2020-2021

Mustafa Kemal University
2006-2007

Bülent Ecevit University
2002-2006

Çankaya University
2005

Ankara Numune Eğitim ve Araştırma Hastanesi
1998-2001

To investigate the effects of anisometropia on binocular function and relationship between stereopsis fusion in anisometropia.Twenty-five patients with were studied. The manifest refraction best-corrected Snellen visual acuity each patient was recorded. Patients, corrected spectacles, evaluated using Bagolini glasses, 4-diopter (D) prism test, Worth four-dot TNO stereotest.All indicated by glasses. Although 4-D test positive anisometropic eye all 25 patients, it slower than response other 19...

10.3928/0191-3913-20010101-09 article EN Journal of Pediatric Ophthalmology & Strabismus 2001-01-01

Abstract. Purpose: To investigate the effects of sildenafil, a popular new drug in treatment erectile dysfunction, on ocular blood flow. Methods: This study was designed as prospective, double‐blind, placebo‐controlled study. Twenty participants with dysfunction were given single oral dose 100 mg while 10 placebo. All underwent routine systemic and ophthalmological examinations. Intraocular pressure, systolic diastolic pressure flow (ophthalmic, central retinal, short posterior ciliary...

10.1111/j.1600-0420.2005.00422.x article EN Acta Ophthalmologica Scandinavica 2005-06-01

AbstractAIM: The aim of this study was to investigate the hemodynamic changes that may occur in retrobulbar circulation after strabismus surgery, using color Doppler ultrasonography (CDI). METHODS. Fifteen healthy volunteers (control group, n=15) and sixteen patients diagnosed with were enrolled study. Either recession or resection planned on one horizontal rectus muscle eyes Group 1 (n=11) two muscles 2 (n=10). CDI performed measure peak systolic velocity (V max ), end-diastolic min ) mean...

10.1076/0927-3972(200003)811-6ft021 article EN Strabismus 2000-01-01

ABSTRACT Purpose: To investigate whether restoration of normal stereo acuity is possible in refractive accommodative esotropia. Methods: Twenty patients with esotropia were included the study. The cycloplegic refraction and best corrected visual each patient recorded. evaluated by 4-prism-diopter test, Bagolini striated glasses, Worth 4-dot TNO fly plate Titmus test. Results: Eight had orthotropia retinal correspondence 12 a small deviation abnormal correspondence. Nine (8 1 microtropia)...

10.3928/0191-3913-20020701-11 article EN Journal of Pediatric Ophthalmology & Strabismus 2002-07-01

Abstract Purpose: To investigate binocularity in Duane’s retraction syndrome (DRS) and to evaluate whether or not there is a relationship between the sensory clinical features of syndrome. Methods: Clinical findings 29 patients with DRS were recorded. Binocularity was tested Bagolini glasses (BG), Worth four‐dot (W4D), TNO stereo‐fly plate Titmus test. Results: Twenty‐four (83%) showed fusion BG at near 23 (79%) had distance. With W4D, 19 (65%) Seven (24%) demonstrated normal stereoacuity,...

10.1111/j.1475-1313.2007.00517.x article EN Ophthalmic and Physiological Optics 2007-10-19

ABSTRACT Purpose To determine whether late surgical correction provides fusion in adults who have constant strabismus beginning early childhood. Materials and Methods This was a prospective study that included 34 consecutive with history of onset had not previously undergone surgery. They were tested the Bagolini striated glasses (BSG), Worth four-dot (W4D) test, cover four-prism diopter (4-PD) preoperatively, 6 weeks after Results The mean age 23.8 years, 17 patients esotropia exotropia....

10.1080/2576117x.2020.1787017 article EN Journal of Binocular Vision and Ocular Motility 2020-07-02

Apart from the known factors that cause toxic optic neuropathy, there may be have not yet been identified. We report a 32-year-old man who presented with complaint of decreased vision. His discs were diffusely covered black pigment, and below atrophic. The vessels appeared to disappeared pigmentation. He reported smoking tobacco, drinking alcohol, using cannabis. vision in both eyes began decreasing gradually after he started bonsai, synthetic cannabinoid, 2 years previously. No case...

10.1080/01658107.2021.1903510 article EN Neuro-Ophthalmology 2021-05-25

In the last few decades, Duane's syndrome (DS) has begun to be classified under as one of congenital cranial dysinnervation syndromes (CCDDs), its primary cause is neurogenic. Incomplete forms DS have been described very recently. This case appears first report association an incomplete with synkinesis levator and lateral rectus a severe complex example CCDD.

10.1080/01658107.2021.1965171 article EN Neuro-Ophthalmology 2021-08-25
Coming Soon ...