Ruth Flavia Vera Villamil Jaimes

ORCID: 0000-0002-2648-1151
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Corrosion Behavior and Inhibition
  • Electrochemical Analysis and Applications
  • Analytical Chemistry and Sensors
  • Hydrogen embrittlement and corrosion behaviors in metals
  • Water Quality Monitoring and Analysis
  • Various Chemistry Research Topics
  • Electrochemical sensors and biosensors
  • Advanced Chemical Sensor Technologies
  • Gold and Silver Nanoparticles Synthesis and Applications
  • Conducting polymers and applications
  • Plasmonic and Surface Plasmon Research
  • Titanium Alloys Microstructure and Properties
  • Bone Tissue Engineering Materials
  • Nanowire Synthesis and Applications
  • Silicon Nanostructures and Photoluminescence
  • Advanced biosensing and bioanalysis techniques
  • Molecular Junctions and Nanostructures
  • Orthopaedic implants and arthroplasty
  • Welding Techniques and Residual Stresses
  • High-Temperature Coating Behaviors
  • Advanced materials and composites
  • Semiconductor materials and devices
  • Photonic Crystals and Applications
  • Gas Sensing Nanomaterials and Sensors

Universidade Federal do ABC
2016-2023

Universidade de São Paulo
2007-2021

Rede de Química e Tecnologia
2019

University of Victoria
2016

Villares Metals (Brasil)
2007

Control of the surface plasmon resonance (SPR) enhanced light transmission through array nanoholes on gold films was achieved by modifying metal with a thin layer electroconductive polymer film. The electrochromic properties were then triggered tuning electrochemical potential. Conducting polymer-modified nanohole electrodes prepared electrodeposition polypyrrole (PPy) using cyclic voltammetry. Only surfaces inside holes accessible for film formation. doping level PPy tuned potential...

10.1021/acsphotonics.6b00607 article EN ACS Photonics 2016-11-08

This work deals with a portable device system applied to detect and classify different metallic ions as proposed developed, aiming its application for hydrological monitoring systems such rivers, lakes groundwater. Considering the features, colorimetric was developed by using multispectral optoelectronic sensor. All technology of quantification classification sensors fully integrated in embedded hardware FPGA ( Field Programmable Gate Array) software based on virtual instrumentation (NI...

10.3390/s17081730 article EN cc-by Sensors 2017-07-28

Abstract In order to evaluate its application as a dental prosthesis material, CoCrW alloy was subjected in vitro cytotoxicity test, surface characterization and electrochemical studies performed artificial saliva 0.15 mol.L-1 NaCl medium. The used techniques were: anodic polarization curves, chronoamperometric measurements, impedance spectroscopy (EIS), scanning electron microscopy (SEM), energy dispersive X-ray (EDS) analysis photoelectron (XPS). Cytotoxicity test also performed. behavior...

10.1590/0103-6440201300513 article EN cc-by Brazilian Dental Journal 2016-04-01

In the present work, a portable device system applied in detection and classification of different metallic ions was proposed developed, aiming at its application monitoring hydrological systems like rivers, lakes groundwater. Considering features, colorimetric developed by using multispectral optoelectronic sensor. All technology quantification Optoelectronic Multispectral sensors fully integrated embedded hardware FPGA software based on virtual Instrumentation (NI LabView ®). The...

10.20944/preprints201706.0058.v1 preprint EN 2017-06-13

O aço inoxidável P558, isento de níquel, vem sendo estudado pelo grupo com o objetivo verificar a viabilidade do seu emprego em implantes ortopédicos. Em trabalhos anteriores, foi mostrado, por técnicas eletroquímicas estacionárias, que ele apresenta, meio cloreto sódio 0,11 mol L-1, comportamento semelhante ao ISO 5832-9 e bem superior 5832-1, mais conhecido como F138. Nesse trabalho, estudada evolução temporal da interfase P558/NaCl L-1 empregando técnica espectroscopia impedância...

10.1590/s0370-44672007000100010 article PT Rem Revista Escola de Minas 2007-03-01

Detection of a single molecule is highly fluctuating event in surface-enhanced Raman scattering (SERS) measurements. Explaining these dynamic blinking events remains challenge. To investigate this behavior, we manufactured Au nanocylinder arrays. A monolayer nicotinamide adenine dinucleotide (NAD) on the array exhibited intense and lines. Persistent lines were not observed over time. These fluctuations discussed within back-action parametric interaction between plasmon mode vibrational...

10.1364/ome.434894 article EN cc-by Optical Materials Express 2021-08-23

This work presents an experiment done for chemistry students about the effect of nature electrolyte and interface on hydrogen evolution reaction by electrolysis.Two techniques are suggested: method A -two identical copper electrodes in a direct current circuit B -three different dc potentiostatic circuit, with electrode (working), platinum (counter) silver-silver chloride-KCl sat (reference).The was observed using technique increasing potentials between two visual observation gas production...

10.21577/0100-4042.20170335 article EN cc-by-nc Química Nova 2019-01-01

The Oxygen (O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> ) gas detection is important in many activities of life and environment control. present work proposed a photoluminescent O sensor device based the metal insulating semiconductor (MIS) capacitor. system used MIS capacitor as photodetector where it was directly integrated active film. results obtained pointed out that exhibit high sensitivity to presence molecules, showing...

10.1109/inscit59673.2023.10258486 article EN 2023-08-28

Foi estudado o comportamento eletroquímico a 37°C do aço inoxidável ISO 5832-9, em meios de NaCl 0,9 %, Ringer Lactato e meio mínimo Eagle (MEM), por voltametria linear análises da superfície microscopia eletrônica varredura (MEV) espectroscopia dispersão energia (EDS). Foram feitos ensaios mecânicos testes toxicidade. O 5832-9 se encontra passivado no potencial corrosão não apresenta pite nos três estudados toda faixa investigada, desde até 50 mV acima transpassivação. Em MEM, entanto, as...

10.1590/s0370-44672010000100028 article PT Rem Revista Escola de Minas 2010-03-01

Nowadays the metal ions detection and classification in-site in real time river like environment are very important task for environmental control. In this sense, present work proposed a portable multispectral spectrometer based photodetector eliminating way complex expensive conventional monochromator system. The acquisition, control processing of signals performed on FPGA technology, which was developed virtual instrumentation software (NI LabView ®), manufactured by National Instruments,...

10.1109/inscit.2019.8868861 article EN 2019-08-01
Coming Soon ...