Per Norrlund

ORCID: 0000-0002-4967-5207
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Frequency Control in Power Systems
  • Power System Optimization and Stability
  • Wind Turbine Control Systems
  • Cavitation Phenomena in Pumps
  • Hydraulic and Pneumatic Systems
  • Microgrid Control and Optimization
  • Water Systems and Optimization
  • Electric Power System Optimization
  • Integrated Energy Systems Optimization
  • Hydraulic flow and structures
  • Water-Energy-Food Nexus Studies
  • Optimal Power Flow Distribution
  • Smart Grid Energy Management
  • Global Energy Security and Policy
  • Power Systems and Renewable Energy
  • Vehicle Noise and Vibration Control
  • Power System Reliability and Maintenance
  • Advanced Battery Technologies Research
  • Electric and Hybrid Vehicle Technologies
  • HVDC Systems and Fault Protection
  • Engineering Applied Research

Uppsala University
2015-2024

Vattenfall (Sweden)
2015-2024

Abstract There is a general need to change hydropower operational regimes balance the growing contribution of variable renewable energy sources in power systems. Quantifying burden on generation equipment increasingly uncertain and difficult. Here, we propose framework combining technical economic indicators analyze primary frequency control (PFC) timescale seconds. We develop model integrating hydraulic, mechanical, electrical subsystems characterize efficiency loss, wear fatigue,...

10.1038/s41467-018-05060-4 article EN cc-by Nature Communications 2018-07-02

This paper presents a mathematical model of hydro power units, especially the governor system for different operating conditions, based on basic version software TOPSYS. The consists eight turbine equations, one generator equation, and which are solved ten unknown variables. under various presented discussed in detail. All essential non-linear factors (dead-zone, saturation, rate limiting, backlash) also considered. Case studies conducted Swedish plant (HPP) three Chinese plants. simulation...

10.3390/en80910260 article EN cc-by Energies 2015-09-17

10.1016/j.ijepes.2015.07.003 article EN International Journal of Electrical Power & Energy Systems 2015-07-23

Nowadays, the wear and tear of hydropower turbines is increasing, due to more regulation movements caused by increasing integration intermittent renewable energy sources. In this paper, a controller filter proposed as solution tradeoff between reducing maintaining performance thereby frequency quality power systems. The widely used dead zone compared with floating linear filter, time-domain simulation frequency-domain analysis. Simulink models are built onsite measurement. Then, investigate...

10.1109/tpwrs.2016.2590504 article EN IEEE Transactions on Power Systems 2016-07-18

The dynamic behavior of hydropower plants participating in primary frequency control is investigated this paper through response, step and setpoint change tests on three Swedish plants. Gray-box system identification used to estimate the parameters simple linear models suitable for power analysis major shortcomings are discussed. It found that response with sinusoidal input signals give more reliable information about dynamics than tests. also shown backlash runner guide vane regulating...

10.1109/tec.2015.2425915 article EN IEEE Transactions on Energy Conversion 2015-05-19

The grid frequency quality in the Nordic power system has been deteriorating during last decade. To improve situation, a better understanding of is needed. In this paper, model dynamics with respect to normal operation control set up and compared full-scale measurements on system. "60 s oscillation" measured explained by model.

10.1109/pesgm.2016.7741711 article EN 2016-07-01

The upcoming modifications to the criteria for providing Frequency Containment Reserves (FCR) in Nordic synchronous area present severe challenges some hydropower units. By quantifying difference between required FCR power response and actual provided by unit, an additional from energy storage system can be specified augment thus securing its participation future. A practical method control system, applying a band-pass filter on negative frequency deviation, is presented this paper. verified...

10.1109/tec.2023.3269621 article EN IEEE Transactions on Energy Conversion 2023-04-24

Currently, the Thoma criterion is often violated to diminish cross-section of surge tank; therefore, fluctuation aggravated and frequency stability becomes more deteriorative. The focus this article on stabilizing low-frequency oscillation an isolated hydropower plant caused by fluctuation. From a new perspective operation mode, under power control investigated compared with adopting Hurwitz numerical simulation. In theoretical derivation, governor equations are introduced mathematical...

10.1080/15325008.2015.1049722 article EN Electric Power Components and Systems 2015-08-05

Power systems are making a transition from purely technical, centrally planned to market based, decentralized systems. The need for balancing power and frequency control reserves increasing, partially due variable renewable production, which gives an opportunity new incomes but also challenge in terms of changed modes operation with risk reduced lifetime controllable plants. This paper investigates how the allocation sold volume within large hydropower production fleet can affect costs...

10.1109/tpwrs.2017.2702280 article EN IEEE Transactions on Power Systems 2017-05-12

10.1016/j.ijepes.2017.12.007 article EN International Journal of Electrical Power & Energy Systems 2018-01-04

Since a few years, there has been tendency that hydropower turbines experience fatigue to greater extent, due increasingly more regulation movements of governor actuators. The aim this paper is extend the service life turbines, by reasonably decreasing guide vane (GV) with appropriate strategies, e.g. settings PI (proportional-integral) parameters and controller filters. accumulated distance number GV are two main indicators study. core method simulate long-term opening Francis...

10.1088/1755-1315/49/5/052013 article EN IOP Conference Series Earth and Environmental Science 2016-11-01

The grid frequency stability is decreasing in many AC grids due to less inertia these systems, and their commonly evaluated through simulation. Hydropower often delivers control, yet research on hydropower model validation for large disturbances scarce. We performed control tests a Kaplan unit three models (called the standard grey-box, white-box models) against data. grey-box parameters were identified with system identification, whereas used index test data relate guide vane opening runner...

10.1109/tec.2020.3029636 article EN IEEE Transactions on Energy Conversion 2020-10-09
Coming Soon ...