Arman Ghaderi Baayeh

ORCID: 0000-0002-5945-2023
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Power Systems Fault Detection
  • Electrical Fault Detection and Protection
  • Lightning and Electromagnetic Phenomena
  • Power System Optimization and Stability
  • Power System Reliability and Maintenance
  • Wireless Power Transfer Systems
  • Vibration and Dynamic Analysis
  • Energy Harvesting in Wireless Networks
  • Microgrid Control and Optimization
  • Magnetic Field Sensors Techniques
  • Smart Grid Security and Resilience
  • Geomagnetism and Paleomagnetism Studies
  • Hybrid Renewable Energy Systems
  • Power Systems and Renewable Energy
  • High voltage insulation and dielectric phenomena
  • Electromagnetic Launch and Propulsion Technology
  • Islanding Detection in Power Systems
  • Wind Turbine Control Systems
  • Wireless Body Area Networks
  • HVDC Systems and Fault Protection
  • Power Transformer Diagnostics and Insulation
  • Power Line Inspection Robots
  • Machine Fault Diagnosis Techniques
  • Smart Grid and Power Systems
  • Optimal Power Flow Distribution

KU Leuven
2023-2024

Iran University of Science and Technology
2016-2021

University of Kurdistan
2019-2021

Aalborg University
2020

This study presents a non‐communication based algorithm for detection of secondary arc extinction adaptive single phase auto‐reclosing transmission lines. The is on the behaviour pattern faulted voltage magnitude (VM) measured at near end line. A prediction function used to calculate present VM few milliseconds in advance its actual measurement. difference between and calculated values as criterion extinction. new method proposed analyse which does not need predefined threshold level. uses...

10.1049/iet-gtd.2016.0960 article EN IET Generation Transmission & Distribution 2016-11-08

This paper presents a reliable and fast index to detect the instant of arc extinction for adaptive single-pole automatic reclosing (ASPAR). The proposed method is simple technique ASPAR on shunt compensated transmission lines using Hilbert–Huang Transform (HHT). HHT combination empirical mode decomposition (EMD) Hilbert transform (HT). first intrinsic function (IMF1) decomposed by EMD, which contains high frequencies faulty phase voltage, was used calculate index. HT calculates IMF spectrum...

10.3390/en13205416 article EN cc-by Energies 2020-10-16

In traditional low voltage networks, energy storage systems are mainly used by consumers to protect against short-term power outages. With the advent of microgrids and expansion distributed generation resources also, development system technology, role storages increasing. By proposed control system, battery (BESS) participates in microgrid management also plays a regulation compensating for current harmonic, unbalance, reactive due presence nonlinear loads. this paper, fuzzy logic-based is...

10.1109/sgc52076.2020.9335758 article EN 2020-12-16

The occurrence of low-frequency electromechanical oscillations is a major problem in the effective operation power systems. scrutiny these provides substantial information about system stability and security. In this paper, new method introduced based on combination synchrosqueezed wavelet transform stochastic subspace identification (SSI) algorithm to investigate large-scale Then, estimated modes are used for design stabilizer flexible alternating current transmission (FACTS) device....

10.35833/mpce.2019.000496 article EN Journal of Modern Power Systems and Clean Energy 2021-01-01

Geomagnetically induced currents (GICs) in the power system cause half-cycle saturation of transformers, malfunction protective relays, reactive loss, and voltage instability. A DC Flux Blocker (DFB) that can be installed series with transformers tertiary windings to neutralize magnetomotive force (mmf) due GIC is described. The device consists two circuit breakers a low high current source, which provides mmf flux blocking function. effectiveness proposed electrical investigated validated...

10.1109/psc49016.2019.9081556 article EN 2019 International Power System Conference (PSC) 2019-12-01

With the advent of microgrids (MG) and increasing use renewable energy sources (RES), conventional low voltage networks change their structure from passive to active. The inherent oscillation nature RESs, such as wind turbine units (WT), can lead adverse effects power quality system stability issues. therefore, storage systems (ESSs) becomes one feasible solution mitigate output fluctuations WT unit. In this paper, a Battery Energy Storage System (BESS) is used in order smooth based on...

10.1109/pedstc52094.2021.9405907 article EN 2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) 2021-02-02

10.1016/j.ijepes.2020.106744 article EN International Journal of Electrical Power & Energy Systems 2021-01-11

This paper presents a novel approach for real-time fault location in medium voltage (MV) cables, single-phase to ground faults. The method is based on the sheath currents. By utilizing instantaneous measurements of and current at cable's sending end, voltages currents sheaths receiving end are computed. A criterion then introduced, relying calculated cable current. offers two advantages: it operates time-domain which minimizes phasor calculation error, doesn't require communication. method's...

10.1049/icp.2024.0860 article EN IET conference proceedings. 2024-04-08

Geomagnetically induced currents (GICs) in long high‐voltage transmission lines cause half‐cycle saturation of transformers, malfunction protective relays, reactive power loss, and voltage instability. This study describes the design for a GIC effects mitigation device (GEMD) that can be installed at system autotransformer common node connection to block flow DC flux cores autotransformers. The devices consist variable resistors, which are controlled by wide‐area method based on particle...

10.1049/iet-gtd.2020.0055 article EN IET Generation Transmission & Distribution 2020-10-22

The loss of excitation (LOE) fault is known as one the most frequent electric generators' internal faults. Conventional methods based on impedance measurements slow down protection system and cause mal-operation during power swing. This study proposes a new approach for LOE detection in synchronous generators where changes generator armature current after are used this purpose. By applying EMD Hilbert-Transform to signal, proposed Index calculated. Based Index, can be distinguished from...

10.1109/ipaps52181.2020.9375596 article EN 2020-12-30

This paper proposes a novel online method to locate single-phase ground faults on medium voltage (MV) cables. The proposed exploits the relationship between cable's and current, in particular, sheaths currents. Using measured phasors of voltages currents sending end cable, at receiving are calculated. Based equality calculated criterion is estimate fault location. As two major advantages, it compatible with inverter-base generation does not rely real-time communication. testified by 960...

10.1049/icp.2023.0703 article EN IET conference proceedings. 2023-07-04

The online estimating of grounding resistances medium voltage cable sheaths makes it possible to monitor their zero-sequence impedance. This paper proposes a resistance estimation method for three-phase single-core cables. uses the phasors measured and currents sending end Pi-model estimate current main conductor at receiving end. Then, using cable's end, sheaths' both ends are calculated. A set 1600 transient power system simulations proves is effective. error less than 71 <tex...

10.1109/smagrimet58412.2023.10128688 article EN 2023-04-24

Capacitive wireless power transfer (CPT) employs an electric field to transmit energy through a medium. Air is the most often used and well-understood However, CPT can also bridge other solid media even benefit from them as dielectric properties of medium govern strength capacitive coupling. The parasitic elements coupling are influenced by medium, in particular leakage resistance. In this work, analytical model proposed that quantifies resistance losses systems for media. validated both...

10.2139/ssrn.4577204 preprint EN 2023-01-01

The power system low-frequency electromechanical oscillations examine in this paper using a maiden method that is combination of the Prony algorithm and Synchrosqueezed short-time Fourier Transform. primary purpose large scale systems control improving modes damping, therefore, estimation these are necessary two types local inter-area. formulation controller design assumed as multiobjective optimization problem intended parameters gained here by Residual Particle Swarm Optimization (PSO)...

10.1109/icee50131.2020.9260892 article EN 2020-08-04
Coming Soon ...