Geraldo Alberto Pinheiro de Carvalho

ORCID: 0000-0002-6279-3558
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Dental materials and restorations
  • Dental Implant Techniques and Outcomes
  • Dental Research and COVID-19
  • Dental Radiography and Imaging
  • Orthopaedic implants and arthroplasty
  • Healthcare during COVID-19 Pandemic
  • Bone Tissue Engineering Materials
  • Electrospun Nanofibers in Biomedical Applications
  • Orthodontics and Dentofacial Orthopedics
  • Healthcare Regulation
  • Advanced materials and composites
  • Endodontics and Root Canal Treatments
  • Innovative concrete reinforcement materials
  • Additive Manufacturing Materials and Processes
  • Material Properties and Applications
  • Bone health and osteoporosis research
  • Digital Imaging in Medicine
  • COVID-19 Impact on Reproduction
  • Concrete Corrosion and Durability
  • Academic Research in Diverse Fields
  • COVID-19 and Mental Health
  • Anatomy and Medical Technology
  • Temporomandibular Joint Disorders
  • Additive Manufacturing and 3D Printing Technologies
  • Advanced ceramic materials synthesis

Faculdade São Leopoldo Mandic
2018-2022

Universidade Cidade de São Paulo
2018

Universidade Católica de Brasília
2014

In this study, 3D printing resins were evaluated, using digital light processing technology, verifying their accuracy. For this, a plaster model was produced from prefabricated synthetic resin model, which scanned by SHINING bench scanner, generating an STL file. This file used as reference measurements, they printed printer, DLP Anycubic Photon, thirty models (N=30) with 3 different (n=10), namely: Low Smell Skin, Prizma - Model DM-300 and Smart Print LCD Model. After the also scanned. The...

10.36692/v17n1-17 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2025-02-13

Introduction: Composite resins are highly aesthetic restorative materials, with nanohybrid being the most indicated for anterior tooth restorations due to their excellent physical and mechanical properties, gloss, surface smoothness, good wear resistance. The fabrication of using CAD/CAM system has become increasingly widespread in field Dentistry. is a technology widely used various industries was introduced into Dentistry late 1970s. These technologies based on three essential phases:...

10.36692/v17n2-5r article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2025-04-01

Introdução: A técnica de carga imediata em implantes tem ganhado destaque na Implantodontia, especialmente regiões estéticas, onde a demanda por resultados rápidos e satisfatórios é maior. evolução do fluxo digital odontologia permitido aprimorar o planejamento previsibilidade desses procedimentos, proporcionando uma experiência mais eficiente personalizada para paciente. Materiais métodos: Esta revisão literatura baseou-se busca análise publicações científicas nas bases dados PubMed, SciELO...

10.36692/v17n2-13r article PT Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2025-04-01

The aim of this study was to compare, through a compression test, resin modified with 5% particulate carbon fibers an acrylic (Dencôr- Artigos Odontológicos Clássico, Campo Limpo Paulista, Brasil) two convencional resins. Ten specimens 6mm in diameter by 12mm length were made for each material: Duralay (Reliance Dental, Illinois, EUA), Pattern Resin (GC America, Chicago, EUA) and Dêncor (Artigos – fibers. 30 test submitted the using universal mechanical machine EMIC DL-2000 (São José dos...

10.36692/v17n1-44 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2025-03-31

Introdução: A técnica de carga imediata em implantes tem ganhado destaque na Implantodontia, especialmente regiões estéticas, onde a demanda por resultados rápidos e satisfatórios é maior. evolução do fluxo digital odontologia permitido aprimorar o planejamento previsibilidade desses procedimentos, proporcionando uma experiência mais eficiente personalizada para paciente. Materiais métodos: Esta revisão literatura baseou-se busca análise publicações científicas nas bases dados PubMed, SciELO...

10.36692/v17n2-16r article PT Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2025-04-07

Desde que foram registrados os primeiros contágios, uma infecção por coronavírus (Covid-19) deu maneira bastante rápida. Neste cenário, dentre EPI's (Equipamentos de Proteção Individual), mais ganharam destaque no combate à doença as máscaras cirúrgicas como forma prevenção desse contágio. Alguns protocolos devem ser seguidos para usar correta. Além das cirúrgicas, nos casos aplicáveis, faz-se necessário o uso proteção respiratória. No entanto, e respiratória cirúrgica vem desempenhando um...

10.31005/iajmh.v3i0.73 article PT InterAmerican Journal of Medicine and Health 2020-03-30

This study assessed, through finite element analysis, the biomechanical behavior of an implant system using All-on-Four® technique with nickel-chromium (M1) and polyether ether ketone (PEEK) bars (M2).Implants components were represented in three-dimensional (3D) geometric models submitted to three types load: axial, oblique, load on all teeth. The 3D exported a computer-aided design-like software such as Solidworks 2016 (Dassault Systemes, Corps, USA) for editing Nonuniform Rational Basis...

10.4103/jispcd.jispcd_183_18 article EN Journal of International Society of Preventive and Community Dentistry 2018-01-01

Em dezembro de 2019, um surto pneumonia começou na China e se espalhou por várias regiões geográficas, sendo causado pelo vírus que chamamos Coronavírus, ou como muitos chamam, Covid -19. Os dados acerca do relatam o mesmo apresenta uma elevada capacidade infecção. Levando em conta as características atendimento odontológico, incluem proximidade face a entre os cirurgiões-dentistas pacientes, faz-se necessário cuidado redobrado relação ao manejo paciente, limpeza consultório proteção dos...

10.31005/iajmh.v3i0.86 article PT other-oa InterAmerican Journal of Medicine and Health 2020-04-08

This study aims to assess the biomechanical behavior of alveolar bone surrounding implants over protocol with metal, Polyether ether ketone (PEEK) and Zantex bars, in normal osteoporotic conditions. For simulation, geometric models mandibular arch were designed containing 5 two variables. The first variable is condition - osteoporotic-, second material used bars – PEEK Zantex. Simulation was performed using Finite Elements Method. Results showed that largest load peaks concentrated medullary...

10.33448/rsd-v11i2.26183 article EN Research Society and Development 2022-02-06

The aim of this study is to analyze the compressive strength occlusal splints manufactured with three different liquid resins in a 3D printer and angles orientation. used here are (n=12): Resilab Clear (Wilcos do Brasil, Petrópolis, RJ, Brazil), Prizma Smart Print Bio (Makertech Labs, Tatuí, SP, Cosmos Splint (Yller Biomateriais, Pelotas, RS, Brazil); each resin group divided into subgroups according orientation manufacture: 0, 45 90 degrees. A dental manikin was scanned file manufacture...

10.33448/rsd-v11i3.26820 article EN Research Society and Development 2022-03-01

Abstract Aim: This study aimed at evaluating with the three-point flexural test, bonding strength of tetragonal zirconia polycrystalline stabilized by yttria zirkonzahn (Y-TZP) and two coating ceramics (Ice e Vision Zircon), surface treatments (treated untreated). Materials Methods: Forty Y-TZP bars were divided into four groups (n = 10): vision zircon/without treatment (VZ/woT), zircon/with (VZ/wT), ice/without treatment, ice/with (I/wT). The assay was conducted using a 50 N load cell 1...

10.4103/ejgd.ejgd_100_17 article EN cc-by-nc-nd European Journal of General Dentistry 2018-01-01

Introduction: Prostheses over implants in the digital flow have been used a number of clinical contexts with efficacy both terms adaptability and durability. Objective: present study aims to compare machined zirconia crowns (Ceramill Zolid FX Multilayer - AmannGirrbach), scanned bench scanner (Ceramil map 300) cemented on TiBase, which is currently traditional method for retention these types crown, UCLA, represents an option technique. Methodology: Thirty divided into two groups (n=15)...

10.36692/v16n2-46 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2024-01-01

Introduction: New systems for adhesive cementation have been increasingly developed and used in daily clinical practice the of ceramic prostheses. Differences chemical composition various system components can influence bond strength between resin cement ceramic. Objective: This study aims to evaluate two systems—feldspathic porcelain yttria-stabilized zirconium oxide—and three different cementation: Rely X ARC, Multilink System, UCem. Methodology: Thirty discs Noritake feldspathic thirty...

10.36692/v16n1-66 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2024-03-31

Objective: To evaluate the strength of composite resins used for fabrication complete dentures after addition niobium pentoxide (Nb2O5). Methods: Different concentrations Nb2O5 were added to polymer matrix: 0% (control), 0.5%, 1.0%, 1.5%, and 2.0% per 100 mg resin. In this context, nanoparticles incorporated under ideal conditions, test specimens designed using Dentsply Sirona’s inLab MC XL software. After nanoparticles, samples printed with dimensions 25 mm in width, 2 height, thickness....

10.36692/6kmknd07 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2024-07-24

This research aims to evaluate the accuracy of four intraoral scanner models in full-arch scans. A master model was scanned using a high-precision desktop scanner, and digital reference created. The then ten times by each scanners studied (TRIOS® 3, CEREC OmniCam, iTero™, Medit i500). were compared 3D measurement software. analysis revealed significant differences among scanners, with iTero™ showing best performance (p=0.0003). All exhibited an average discrepancy less than seventy...

10.36692/v16n2-77 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2024-08-30

The objective of this study is to evaluate the accuracy and precision full arch maxillary digital scans produced by six scanners. Materials Methods: A standard model was scanned a reference scanner obtain model. This same then ten times three intraoral scanners benchtop scanners, which are: CS3600 (Carestream Health, Rochester, New York, USA), iTero element 2 (Align Technology, San José, California, Trios (3Shape, Copenhagen, Denmark), Ceramill Map 400 (Amann Girrbach, Koblach, Feldkirch...

10.36692/v16n2-78 article EN Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida 2024-06-07

We used finite elements analysis to assess the biomechanical behavior of lower protocol bars made Polyether Ether Ketone (PEEK) reinforced by carbon fiber, with different designs on All-on-four® system, subjected physiological occlusal loads. The models were built have an I-shaped or inverse T-shaped section. also assessed stress distribution peri implant bone, implants, prosthetic intermediates, intermediate screws, and screws. In simulations, strength peaks similar for both T I shaped...

10.31005/10.31005/iajmh article EN cc-by InterAmerican Journal of Medicine and Health 2019-06-18

A cavidade oral apresenta características bastante abrangentes para o desenvolvimento de microorganismos e é considerada uma abertura a entrada dos mesmos. Microrganismos causados ​​pela boca podem causar infecções generalizadas, como pneumonia sepse. Em pacientes internados em unidades terapia intensiva (UTIs), muitas dessas complicações ser evitadas caso tratamento esteja vinculado um atendimento odontológico. Esses atendimentos são feitos nas luvas realizados por cirurgiões dentistas da...

10.31005/iajmh.v3i0.74 article PT other-oa InterAmerican Journal of Medicine and Health 2020-03-30

O novo Coronavirus (SARS-CoV-2) representa um desafio para a Organização Mundial de Saúde (OMS) e os sistemas saúde no Brasil em todo o mundo. vírus possui alta transmissibilidade é responsável pela doença Covid- 19, causadora quadros respiratórios que variam leves graves (Zhou et. al, 2020). Poucos meses após início da epidemia na China final 2019, já haviam mais 2 milhões casos 120 mil mortes mundo por COVID 19 (Werneck, Carvalho, Essa nova rápida progressão tem provocado gerando...

10.31005/iajmh.v3i0.125 article PT cc-by InterAmerican Journal of Medicine and Health 2020-09-30

RESUMO: Uma forma de obter informações quantitativas durante a avaliação postural é por meio da fotogrametria, que permite analisar medida posição, comprimento, ângulo e alinhamento segmentos corporais.Para o uso confiável preciso identificar discutir as fontes erro medição, pois para inferir alterações posturais causa uma lesão, disfunção ou tratamento fisioterápico proceder adequadamente.O estudo tem como objetivo verificar efeito do posicionamento voluntário calibração nas medidas...

10.18511/0103-1716/rbcm.v22n1p30-36 article PT Revista Brasileira de Ciência e Movimento 2014-03-30

A organização mundial da saúde (OMS) e os governos de todo o mundo enfrentam hoje uma grave crise, a pandemia pelo novo Coronavírus. Para enfrentamento à Covid-19, grande extensão territorial do Brasil, com variedade costumes hábitos dos indivíduos, juntamente diversificação das assistências compatíveis cada localidade, representam um desafio para as autoridades na questão planejamento ações. No combate abordagem regionalizada tem sido foco ação muitos em mundo, sendo que no Brasil estrutura...

10.31005/iajmh.v3i0.135 article PT other-oa InterAmerican Journal of Medicine and Health 2020-07-08
Coming Soon ...