Soumya R. Mohanty

ORCID: 0000-0003-0551-7730
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Power Systems Fault Detection
  • Islanding Detection in Power Systems
  • Microgrid Control and Optimization
  • HVDC Systems and Fault Protection
  • Power System Optimization and Stability
  • Smart Grid Security and Resilience
  • Power Quality and Harmonics
  • Frequency Control in Power Systems
  • Smart Grid Energy Management
  • Wind Turbine Control Systems
  • Electrical Fault Detection and Protection
  • Power Systems and Renewable Energy
  • Multilevel Inverters and Converters
  • Machine Fault Diagnosis Techniques
  • Energy Load and Power Forecasting
  • Metal Extraction and Bioleaching
  • Advanced Battery Technologies Research
  • Power System Reliability and Maintenance
  • X-ray Diffraction in Crystallography
  • Advanced DC-DC Converters
  • Crystallization and Solubility Studies
  • Advanced Electrical Measurement Techniques
  • Software-Defined Networks and 5G
  • Iron and Steelmaking Processes
  • High-Voltage Power Transmission Systems

Indian Institute of Technology BHU
2018-2025

Banaras Hindu University
2018-2025

National Institute of Technology Sikkim
2024

Microsoft (India)
2024

Østfold University College
2024

Indian Institute of Technology Madras
2023-2024

Integrated Test Range
2021

Motilal Nehru National Institute of Technology
2010-2019

University of Beira Interior
2012-2013

Instituto Superior Técnico
2012

10.1016/j.rser.2013.08.108 article EN Renewable and Sustainable Energy Reviews 2013-09-29

In this paper, islanding detection in a hybrid distributed generation (DG) system is analyzed by the use of hyperbolic S-transform (HST), time-time transform, and mathematical morphology methods. The merits these methods are thoroughly compared against commonly adopted wavelet transform (WT) (ST) techniques, as new contribution to earlier studies. DG consists photovoltaic wind energy systems connected grid within IEEE 30-bus system. Negative sequence component voltage signal extracted at...

10.1109/tste.2014.2362797 article EN IEEE Transactions on Sustainable Energy 2014-11-04

Time–frequency-based differential scheme is proposed for microgrid protection using non-stationary signal analysis. The processing algorithm Hilbert–Huang Transform (HHT) have been implemented the objective and comparative assessment with that of S-transform, current carried out in order to demonstrate reliability different case studies. series simulation results demonstrates efficacy HHT, than S-transform some critical cases such as high impedance fault where accurate detection a challenge....

10.1049/iet-gtd.2015.1563 article EN IET Generation Transmission & Distribution 2016-07-22

Penetration of distributed generation systems in conventional power leads to quality (PQ) disturbances. This paper provides an improved PQ disturbances classification, which is associated with load changes and environmental factors. Various forms disturbances, including sag, swell, notch, harmonics, are taken into account. Several features obtained through hyperbolic S-transform, out the optimal selected using a genetic algorithm. These used for classification by employing support vector...

10.1109/tste.2013.2278865 article EN IEEE Transactions on Sustainable Energy 2013-10-01

In this paper a novel concept of event triggering control (ETC) for effective resource utilization is proposed dc microgrid. Matched uncertainty elimination possible through sliding mode (SMC) itself as addressed in the literatures. This proposes new approach suppression both matched and unmatched uncertainties grid connected islanded an integral disturbance observer (IDO) which designed with super twisting SMC to provide dual filtering phenomena pertaining system perturbations. The IDO...

10.1109/tsg.2020.2990451 article EN IEEE Transactions on Smart Grid 2020-04-28

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> In this paper, a cumulative-sum-based fault detection algorithm is proposed for the power system relaying application. Literature suggests successful application of method to process control systems where deviation parameters tracked indicate any abnormal conditions. The effectiveness found be better than traditional methods in presence noise, frequency deviation, and other uncertainties. It also...

10.1109/tpwrd.2007.911160 article EN IEEE Transactions on Power Delivery 2008-01-01

This article presents a hybrid optimization technique particle swarm optimization–gravitational search algorithm for optimal over-current relay coordination. The main contribution of this is to find the optimized settings during variation in environmental factors that affect distributed generation performance. detailed model wind and photovoltaic source, modeled PSCAD/EMTDC platform penetrated 13-bus distribution system. are found different cases, including change speed, penetration level,...

10.1080/15325008.2015.1117539 article EN Electric Power Components and Systems 2016-02-18

In this article, a machine-learning-based fault detection and classification method is proposed. Two supervised learning-based protection modules are developed for the relays considered in study—one to detect discriminate between symmetrical or unsymmetrical nature of another faulty phase(s). A robust set features using both relay voltage current signals utilized developing modules. The obtained multiresolution decomposition based on empirical wavelet transform. tested unbalanced IEEE...

10.1109/tii.2024.3359450 article EN IEEE Transactions on Industrial Informatics 2024-02-14

Small-Signal Analysis of Autonomous Hybrid Distributed Generation Systems in Presence Ultracapacitor and Tie-Line Operation This paper presents small-signal analysis isolated as well interconnected autonomous hybrid distributed generation system for sudden variation load demand, wind speed solar radiation. The systems comprise different renewable energy resources such wind, photovoltaic (PV) fuel cell (FC) diesel engine generator (DEG) along with the storage devices flywheel (FESS) battery...

10.2478/v10187-010-0029-0 article EN Journal of Electrical Engineering 2010-07-01

10.1016/j.ijepes.2012.08.020 article EN International Journal of Electrical Power & Energy Systems 2012-09-26

The real-time analysis of power quality (PQ) disturbances and islanding detection for distributed generation (DG) system using signal processing algorithms are still at a premature stage. Quick reliable PQ needs renewed focus. This paper is concentrated on the implementation advanced techniques in field-programmable gate array (FPGA) to identify events real time. proposed scheme based orthogonal empirical mode decomposition (OEMD) implemented FPGA. technique does not suffer from loss...

10.1109/tie.2018.2851968 article EN IEEE Transactions on Industrial Electronics 2018-07-09

ABSTRACT This paper introduces a Relay Integrity and Anomaly Detection (RIAD) scheme designed to enhance the reliability of Setting Group‐based Adaptive Overcurrent (SGAO) protection systems. The RIAD mechanism improves relay configuration awareness mitigates potential failures due misconfigured relays or cyber intrusions targeting settings. To validate performance SGAO proposed RIAD, comprehensive cyber‐physical power system testbed was developed implemented within CIGRE 7‐bus AC microgrid....

10.1002/cta.4508 article EN other-oa International Journal of Circuit Theory and Applications 2025-03-27

The influence of Al 2 O 3 in the range 10–20 mass% and TiO 0.55–5 on flow behavior, viscosity, density, surface tension molten industrial blast furnace slag with CaO/SiO = 1.13 is investigated using a high‐temperature microscope, rotating viscometer, maximum bubble pressure method. measurement results show that acts as network former studied CaO–SiO –MgO–Al –TiO slags. With an increase content from 10 to 20 mass%, viscosity slags density decreases. In contrast , surfactant breaker up 15...

10.1002/srin.202200798 article EN cc-by-nc-nd steel research international 2023-02-09

In this paper, islanding in a distributed generation (DG) based hybrid system is presented on extracted features of wavelet transform (WT), S-transform (ST), Hyperbolic (HST) and TT-Transform. The comprises DG resources like photovoltaic (PV), fuel cell (FC) wind energy systems (WES) connected to the grid. negative sequence component voltage signal at point common coupling (PCC) considered for detection these from study different scenarios form time-frequency analysis. content standard...

10.1109/isgteurope.2012.6465689 article EN 2012-10-01

This paper presents a novel fault detection and identification method for low-voltage direct current (DC) microgrid with meshed configuration. The proposed is based on graph convolutional network (GCN), which utilizes the explicit spatial information measurement data of topology to identify fault. It has more substantial feature extraction ability even in presence noise bad data. adjacency matrix GCN developed by considering as an inherent graph. bus voltage line samples after faults are...

10.35833/mpce.2022.000251 article EN Journal of Modern Power Systems and Clean Energy 2023-01-01

This paper proposes a fault detector for digital relaying based on moving sum index. The of the current samples over one cycle window has been used as qualifier to detect occurrence faults in power system. Simplicity and accuracy are two attractive features method. method is tested under variety disturbance conditions typical A comparative assessment with existing techniques carried out establish effectiveness approach can also be applied classification distance relay.

10.1080/15325000500341769 article EN Electric Power Components and Systems 2006-01-24

In the past one decade, several signal processing techniques for detection and classification of single instant occurrence both power quality (PQ) islanding events have been reported. However, with presence energy resources in system, more critical conditions PQ may arise due to transformer energizing, capacitor induction motor start, even fault at various locations network. As a result, evolving disturbances sequence be observed. This study presents use preserving ensemble empirical mode...

10.1109/tie.2020.3013739 article EN IEEE Transactions on Industrial Electronics 2020-08-19
Coming Soon ...