Michael Schwenke

ORCID: 0000-0003-0662-3949
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • German Literature and Culture Studies
  • Diverse Scientific and Economic Studies
  • Ultrasound and Hyperthermia Applications
  • Ultrasound Imaging and Elastography
  • Law and Political Science
  • Taxation and Legal Issues
  • Corporate Taxation and Avoidance
  • Advanced Radiotherapy Techniques
  • MRI in cancer diagnosis
  • Advanced MRI Techniques and Applications
  • Photoacoustic and Ultrasonic Imaging
  • Gas Dynamics and Kinetic Theory
  • European Union Policy and Governance
  • Corporate Governance and Law
  • Medical and Health Sciences Research
  • European and International Law Studies
  • Ultrasound in Clinical Applications
  • Advanced Neuroimaging Techniques and Applications
  • Ultrasound and Cavitation Phenomena
  • Medical Image Segmentation Techniques
  • Radiomics and Machine Learning in Medical Imaging
  • Fluid Dynamics and Turbulent Flows
  • Cancer Diagnosis and Treatment
  • Metastasis and carcinoma case studies
  • Image and Object Detection Techniques

Institute of European Media Law
2023

Court of Justice of the European Union
2023

Fraunhofer Institute for Digital Medicine
2011-2022

Coca Cola (United States)
2022

Virtuelle Fabrik (Switzerland)
2022

Spitalul Clinic Județean de Urgență Cluj-Napoca
2021

Institut für Unternehmenskybernetik
2021

E Ink (South Korea)
2020

Nutrasource
2020

Fraunhofer Institute for Computer Graphics Research
2020

Focused ultrasound surgery (FUS) is a non-invasive method for tissue ablation that has the potential complete and controlled local tumour destruction with minimal side effects. The treatment of abdominal organs such as liver, however, requires particular technological support in order to enable safe, efficient effective treatment. As FUS applied from outside patient's body, suitable imaging methods, magnetic resonance or diagnostic ultrasound, are needed guide track procedure. To facilitate...

10.3109/02656736.2014.1002817 article EN International Journal of Hyperthermia 2015-03-19

This paper introduces a general implementation procedure for the measurement of harmonic phase angles using Power Quality (PQ) instruments. It is intended to fill this gap standards IEC 61000-4-7 and 61000-4-30, particular with focus on grid measurements. While single time instant well defined, focuses methods aggregate in frequency time. The application illustrated different simulated real data. Moreover, accuracy angle procedures test are provided.

10.1109/amps.2016.7602811 article EN 2016-09-01

Focused ultrasound (FUS) is rapidly gaining clinical acceptance for several target tissues in the human body. Yet, treating liver targets not clinically applied due to a high complexity of procedure (noninvasiveness, motion, complex anatomy, blood cooling effects, shielding by ribs, and limited image-based monitoring). To reduce complexity, numerical FUS simulations can be utilized both treatment planning execution. These use-cases demand highly accurate computationally efficient...

10.1109/tbme.2016.2619741 article EN IEEE Transactions on Biomedical Engineering 2017-05-22

Purpose The accuracy of a numerical simulation cryoablation ice balls was evaluated in gel phantom data as well clinical kidney and lung cases.Materials methods To evaluate the accuracy, 64 experimental single-needle cryoablations 12 multi-needle phantoms were re-simulated with corresponding freeze-thaw-freeze cycles. simulated temperatures compared over time measurements thermocouples. For single needles, temperature values at each thermocouple location. multiple Euclidean distances between...

10.1080/02656736.2020.1845402 article EN cc-by International Journal of Hyperthermia 2020-01-01

Focused ultrasound (FUS) is entering clinical routine as a treatment option. Currently, no clinically available FUS system features automated respiratory motion compensation. The required quality standards make developing such challenging. A novel with compensation described, developed the goal of use. comprises MR device and transducer system. controller very generic could use any suitable or device. image sequences (echo planar imaging) are acquired for both observation thermometry. Based...

10.1186/s40349-017-0098-7 article EN cc-by Journal of Therapeutic Ultrasound 2017-05-30

Design, embodiment, and experimental study of a novel concept extracorporeal phased array ultrasound transducer for prostate cancer regional deep hyperthermia treatments using transperineal acoustic window is presented. An optimized design applicator was derived from modelling software where thermal fields were computed based on anatomical data. Performance tests have been experimentally conducted gel phantoms tissues, under 3T MRI guidance PRFS thermometry. Feedback controlled (ΔT = 5 °C...

10.3390/cancers15010163 article EN Cancers 2022-12-27

Introduction: The novel Trans-Fusimo Treatment System (TTS) is designed to control Magnetic Resonance guided Focused Ultrasound (MRgFUS) therapy ablate liver tumours under respiratory motion. It crucial deliver the acoustic power within tolerance limits for effective tumour treatment via MRgFUS. Before application in a clinical setting, evidence of reproducibility and reliability must safe practice.Materials methods: TTS software delivers ExAblate-2100 Conformal Bone (CBS) transducer. A...

10.1080/13645706.2016.1273836 article EN Minimally Invasive Therapy & Allied Technologies 2017-01-13

Phase-contrast MRI (PC MRI) can be used to assess blood flow dynamics noninvasively inside the human body. The acquired images reconstructed into vector fields. Traditionally, streamlines computed based on fields visualize patterns and particle trajectories.The traditional methods may give a false impression of precision, as they do not consider measurement uncertainty in PC images. In our prior work, we incorporated computation trajectories.As major part contribution, novel numerical scheme...

10.3414/me11.02.0032 article EN Methods of Information in Medicine 2012-01-01

Article Internationale Einkünfteabgrenzung: Anmerkungen zum BFH-Urt. v. 9.8.2023 – I R 54/19 aus Sicht von Herrn Dr. Michael Schwenke, BFH was published on April 1, 2024 in the journal SteuerRundschau (volume 13, issue 4).

10.9785/isr-2024-130403 article DE Internationale SteuerRundschau 2024-03-29

Non-invasive ablation and hyperthermia treatments of abdominal organs using High Intensity Focused Ultrasound (HIFU) still impose severe challenges. Especially for liver kidney treatments, the target motion accessibility over entire respiratory cycle make application HIFU difficult. To allow a safe, effective, efficient treatment, detailed planning monitoring intervention is needed. Current general-purpose physics simulation software cannot fulfill real-time requirements therapy-monitoring...

10.1186/2050-5736-3-s1-p51 article EN cc-by Journal of Therapeutic Ultrasound 2015-06-30

10.1515/bmt-2012-4392 article EN Biomedical Engineering / Biomedizinische Technik 2012-01-06

10.9785/ovs-fr-2012-443 article Finanz-Rundschau Ertragsteuerrecht 2012-01-01

The application of FUS in abdominal organs such as the liver or kidneys is impeded by a number complications. One most challenging organ motion due to breathing. To achieve ablation target within moving system has be steered focus on same anatomical position. We present prototypical that tracks an ex vivo ovine via diagnostic ultrasound (US) and adjusts focal spot fixed

10.1186/2050-5736-3-s1-p52 article EN cc-by Journal of Therapeutic Ultrasound 2015-06-30

Abstract Organ motion is a major problem for Focused Ultrasound Surgery (FUS) of liver tumors. We present phantom mimicking human respiratory (20 mm range, 3 − 7 s/cycle) and the evaluation an ultrasound-tracked steered FUS system on that phantom. Temperature curves are recorded while sonicating in moving static The temperature correlate well show ability to compensate breathing like motion.

10.1515/cdbme-2015-0073 article EN cc-by-nc-nd Current Directions in Biomedical Engineering 2015-09-01