Liangliang Hao

ORCID: 0000-0003-0706-7307
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High voltage insulation and dielectric phenomena
  • Power Transformer Diagnostics and Insulation
  • HVDC Systems and Fault Protection
  • High-Voltage Power Transmission Systems
  • Power Systems Fault Detection
  • Power System Optimization and Stability
  • Power System Reliability and Maintenance
  • Electrical Fault Detection and Protection
  • Machine Fault Diagnosis Techniques
  • Electric Motor Design and Analysis
  • Non-Destructive Testing Techniques
  • Magnetic Properties and Applications
  • Oil and Gas Production Techniques
  • Smart Grid and Power Systems
  • Power Systems and Technologies
  • Lightning and Electromagnetic Phenomena
  • Water Systems and Optimization
  • Multilevel Inverters and Converters
  • Computational Physics and Python Applications
  • Electrostatic Discharge in Electronics
  • Microgrid Control and Optimization
  • Magnetic Bearings and Levitation Dynamics
  • Electrical and Bioimpedance Tomography
  • Advanced Fiber Optic Sensors
  • Sensorless Control of Electric Motors

Beijing Jiaotong University
2014-2023

Kyoto University
2021

GE Global Research (United States)
2012-2013

University of Southampton
2006-2012

Tsinghua University
2010-2011

Partial discharge (PD) measurements are an important tool for assessing the health of power equipment. Different sources PD have different effects on insulation performance apparatus. Therefore, discrimination between is great interest to both system utilities and equipment manufacturers. This paper investigates use a wide bandwidth on-line measurement consisting radio frequency current transducer (RFCT) sensor, digital storage oscilloscope high personal computer facilitate automatic source...

10.1109/tdei.2010.5412017 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2010-02-01

Partial discharge (PD) signals generated within electrical power equipment can be used to assess the condition of insulation. In practice, testing often results in multiple PD sources. order impact individual sources, must first discriminated from one another. This paper presents a procedure for identification by Starting with assumption that different sources will display unique signal profiles this manifested distribution energies respect frequency and time. Therefore technique presented...

10.1109/tdei.2011.6032842 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2011-10-01

This paper proposes a current sensorless control strategy for the dual active bridge (DAB) converter with nonlinear disturbance observer (NDO)-based load feedforward. The proposed method can regulate both dc-bus voltage and of DAB without sensors. Several performance indexes are established parameter design detailed is presented in this paper. When single-phase H-bridge inverter connected, double-frequency oscillation from feedback path suppressed by proper design, while transient response...

10.1109/tpel.2017.2705344 article EN IEEE Transactions on Power Electronics 2017-05-18

Machine learning techniques have been widely used in transient stability prediction of power systems. When using the post-fault dynamic responses, it is difficult to draw a definite conclusion about how long duration response data should be order balance accuracy and speed. Besides, previous studies problem lacking consideration for confidence level. To solve these problems, hierarchical method based on ensemble classifier multiple support vector machines (SVMs) proposed. Firstly, datasets...

10.3390/en9100778 article EN cc-by Energies 2016-09-27

The interturn short circuit of field windings in synchronous machines will cause the current increasing, reactive power output decreasing as well aggravation vibration. In this paper, by using multiloop theory and analyzing steady-state characteristics stator rotor fault currents, expression each loop is obtained, then differential equations system are reduced into linear equations; according to principal that components same frequency equal, solution ac dc can be obtained calculation...

10.1109/tec.2011.2169264 article EN IEEE Transactions on Energy Conversion 2011-10-14

This paper studies the electromagnetic torque (EMT) of a nonsalient-pole synchronous generator with interturn short circuit field windings (ISCFW). First, virtual displacement method serves as basis for analyzing postfault steady-state harmonic characteristic EMT. The interactions among various space magnetic fields different orders, speeds, and rotation directions generated by stator rotor are considered. A general conclusion on EMT characteristics under fault is then derived. Second, based...

10.1109/tec.2014.2350336 article EN IEEE Transactions on Energy Conversion 2014-09-12

In order to maintain the stable operation of power systems, quick and accurate transient stability assessment (TSA) after fault clearance is important. Machine learning methods have been widely used in analysis systems. However, how make good use time series data PMUs effectively balance contradiction between rapidity accuracy brings new challenges TSA. To address this problem, we propose an anti-jitter dynamic evaluation method based on long-short term memory (LSTM) network. model,...

10.1109/access.2020.2974915 article EN cc-by IEEE Access 2020-01-01

Electric propulsion is widely used in ship systems, and multiphase machines are gaining increasing popularity because of their fault‐tolerant ability, high power density, reduced torque ripple. This study concentrates on the tandem configuration with two 15‐phase induction (IMs) fixed same shaft. Based field‐oriented control reconfiguration for single IM, master–slave coordinated strategy designed motors, which can not only achieve allocation between motors during normal operation, but also...

10.1049/iet-epa.2017.0274 article EN IET Electric Power Applications 2017-08-22

A sawtooth carrier-based sinusoidal pulse width modulation (SC-SPWM) technique for asymmetrical six-phase two-level inverters is proposed in this paper, which could reduce both the peak-to-peak amplitude and changing frequency of common-mode voltage (CMV). The intersection-plotting method reveals that mirror symmetrical carriers two three-phase groups can help optimize distribution overlapping areas, CMV reduction mechanism SC-SPWM. Additionally, Fourier analysis employed to quantitatively...

10.1109/tpel.2017.2787733 article EN IEEE Transactions on Power Electronics 2017-12-27

Hybrid high-voltage direct current (HVDC) transmission systems employ a new type of HVDC topology that combines the advantages line-commutated converter system and voltage-source system. They can improve efficiency reliability long-distance power transmission. However, realizing alternating-current (AC) grid-fault ride through on inverter side hybrid is challenge considering based (VSC-HVDC) used side. In this study, control strategy for an overvoltage fixed trigger angle power-balance...

10.1007/s40565-019-0546-1 article EN cc-by-nc-nd Journal of Modern Power Systems and Clean Energy 2019-07-26

To allow utilities to fulfill self-imposed and regulative performance targets that apply them, the demand for new tools help judge health of modern power distribution networks has increased. The analysis partial discharge (PD) signals been identified as a potential diagnostic tool condition monitoring HV plant. In order investigate PD activity produced by range defects within three-phase paper insulated lead covered (PILC) cable under rated conditions, an experiment developed. incorporates...

10.1109/tdei.2013.6678860 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2013-12-01

This paper proposes a novel technique and algorithm for the simultaneous sensing of three-phase currents based on multiple air-core coils. The basic principle current measurement in one conductor using two coils is derived, means self-calibration determined. In order to measure parallel overhead lines, smart sensor has been developed, consisting four located close proximity conductors. Algorithms are simulations extensive experimental verification conducted, first prototype fabricated...

10.1109/tpwrd.2015.2402284 article EN IEEE Transactions on Power Delivery 2015-03-02

A multiphase annular brushless excitation system is widely used in large-capacity nuclear power units. Accurate fault diagnosis of the rotating rectifier great significance to improve reliability system. However, traditional method based on harmonic analysis stator field current has some deficiencies. In this article, a novel using waveforms and artificial intelligence presented. First, various shape features different faults are analyzed. Then, as input hybrid algorithm dynamic time warping...

10.1109/tpel.2023.3278716 article EN IEEE Transactions on Power Electronics 2023-05-22

A machine learning-based approach is proposed to predict the transient stability of power systems after a large disturbance. The post-disturbance trajectories generator rotor angles are taken as whole cluster, and 19 cluster features defined depict overall characteristics systems. hybrid approach, which combines linear support vector with decision tree, generate final classifier. Comprehensive studies conducted on IEEE 39-bus 145-bus test verify performance approach. Test results show that...

10.1080/15325008.2016.1204373 article EN Electric Power Components and Systems 2016-09-20

This paper presents a deep learning approach with cost-sensitive loss function for transient stability assessment (TSA). Firstly, multiple generator variables after disturbance are utilized as the original inputs. Secondly, convolutional neural network (CNN) is applied automatic feature extraction and regression model building TSA. The generated TSA can provide more accurate index than fully-connected support vector model. Moreover, proposed to reduce misdetection of instability. Case...

10.1109/ei2.2018.8582047 article EN 2018-10-01

Two signal classification methods have been examined to discover their suitability for the task of partial discharge (PD) identification. An experiment has designed artificially mimic signals produced by a range PD sources that are known occur within high voltage (HV) items plant. The bushing tap point large Auto-transformer highlighted as possible on which attach sensing equipment and is utilized in this experiment. Artificial injected into HV electrode itself frequency current transformer...

10.1109/elinsl.2010.5549736 article EN IEEE International Symposium on Electrical Insulation 2010-06-01

Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by authors has shown that electro-optic system can be used PD measurement oil-filled transformers. A signal generated within transformer may reach a winding and then travel along to bushing core bar. The bushing, acting like capacitor, transfer high frequency components partial its earthed tap point. Therefore, effective current implemented at using radio...

10.1088/0957-0233/19/5/055707 article EN Measurement Science and Technology 2008-04-21

This paper investigates the recognition of partial discharge sources by using a statistical learning theory, Support Vector Machine (SVM). SVM provides new approach to pattern classification and has been proven be successful in fields such as image identification face recognition. To apply classification, data input is very important. The should able fully represent different patterns an effective way. determination features that describe characteristics signals extraction reliable...

10.1109/scored.2007.4451430 article EN 2007-01-01

Inter-turn short circuit of field windings (ISCFW) may cause the current a generator to increase, output reactive power decrease, and unit vibration intensify, seriously affecting its safe stable operation. Full integration mechanical electrical characteristics can improve sensitivity online monitoring, detect early embryonic period fault small turns. This paper studies calculations variations unbalanced magnetic pull (UMP), which excitation source rotor is basis key monitoring. In grid load...

10.3390/en10050732 article EN cc-by Energies 2017-05-20

As the core of large-capacity nuclear power generation system, multiphase annular brushless exciter (MPABE) may cause a serious catastrophe to plant if it fails. In order effectively protect armature winding MPABE, rapid simulation model and sensitive diagnosis method short-circuit (AWSC) fault are studied systematically in this article. First, article proposes general MPABE with AWSC fault. To verify correctness model, corresponding simulations experiments faults carried out, respectively,...

10.1109/tpel.2022.3200675 article EN IEEE Transactions on Power Electronics 2022-08-22
Coming Soon ...