- Electrochemical sensors and biosensors
- Analytical Chemistry and Sensors
- Electrochemical Analysis and Applications
- Conducting polymers and applications
- Corrosion Behavior and Inhibition
- Molecular Sensors and Ion Detection
- Electrocatalysts for Energy Conversion
- Concrete Corrosion and Durability
- Analytical chemistry methods development
- Analytical Methods in Pharmaceuticals
- Advanced biosensing and bioanalysis techniques
- Hydrogen embrittlement and corrosion behaviors in metals
- Chemical Synthesis and Characterization
- Supercapacitor Materials and Fabrication
- Arsenic contamination and mitigation
- Radioactive element chemistry and processing
- Nanoporous metals and alloys
- Medicinal Plants and Neuroprotection
- Nanomaterials for catalytic reactions
- Bioactive Compounds and Antitumor Agents
- Covalent Organic Framework Applications
- High-Temperature Coating Behaviors
- Chemical Synthesis and Reactions
- Gas Sensing Nanomaterials and Sensors
- Estrogen and related hormone effects
Payame Noor University
2013-2023
University of Tehran
2017
Islamic Azad University of Nishapur
2017
Shiraz University
1996-2001
Abstract A lead ion-selective electrode based on dibenzopyridino-18-crown-6 as membrane carrier was successfully prepared. The exhibits a Nernstian response for Pb2+ ions over wide concentration range. Influences of the nature plasticizer, concentrations internal solutions in electrodes and composition were investigated. exhibited comparatively good selectivities with respect to alkali, alkaline earth some transition heavy metal ions.
In this study, ZnO-Red Ochre nanocomposite was green synthesized by Rosa Damascena (RD) extract (RDZRONCs). Proton Induced X-ray Emission microanalysis (Micro-PIXE) and diffraction (XRD) pattern confirmed the presence of hematite (Fe2O3), quartz (SiO2) mineral phases in Red (RO) nanoclay. addition, XRD shows ZnO, ZnFe2O4, SiO2, Fe2O3, Si RDZRONCs that were with natural RD RO. The used to modify carbon paste electrode (CPE) for electrochemical determination anticancer drug 5-fluorouracil...
The increasing application of aptamers in bioassays has triggered a lot research interest for development highly sensitive and selective sensing platforms. Herein, we report on the design cocaine biosensor by immobilizing 5'-disulfide-functionalized end an aptamer sequence nanoporous gold (NPG) electrode followed conjugation its 3'-amino-functionalized to 2,5-dihydroxybenzoic acid (DHBA) as redox probe. In presence cocaine, undergoes conformational change from open unfolded state closed...
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) has been developed for preconcentration and determination of tramadol, ((±)-cis-2-[(dimethylamino)methyl]-1-(3-methoxyphenyl)cyclohexanol-HCl), in aqueous biological samples (urine, blood). DLLME is a simple, rapid efficient method drugs samples. Efficient factors on the process defined optimized extraction tramadol including type disperser solvents their volumes, pH donor phase, time...
A simple and sensitive method using mini-column packed with multi-walled carbon nanotubes (MWCNTs) combined graphite furnace atomic absorption spectrometry (GFAAS) for preconcentration determination of ultra trace amounts As(III) in an aqueous medium is proposed. The procedure based on the solid phase extraction As(III)-sodium diethyldithiocarbamate (As-NaDDTC) chelate MWCNTs. Various parameters such as effect pH, eluent type volume, amount sorbent, matrix effects quantitative recoveries...
The non-enzymatic voltammetric and amperometric detection of glucose using a palladium coated nanoporous gold film electrode is described. effect surfactant on the fabrication was also investigated. performed by cyclic voltammetry. sensor had good electrocatalytic activity towards oxidation glucose, exhibited rapid response (~6 s), gave linear range from 1 to 33 mM with limit 5 μM (with signal noise ratio 3). wide dynamic range, long-term stability, high sensitivity selectivity,...