Eric Christie

ORCID: 0000-0003-1799-9140
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced X-ray Imaging Techniques
  • Mass Spectrometry Techniques and Applications
  • Ion-surface interactions and analysis
  • Low-power high-performance VLSI design
  • Medical Imaging Techniques and Applications
  • Electrohydrodynamics and Fluid Dynamics
  • High-pressure geophysics and materials
  • Nuclear Issues and Defense
  • Advancements in Semiconductor Devices and Circuit Design
  • Atomic and Subatomic Physics Research
  • Analog and Mixed-Signal Circuit Design
  • Nuclear Physics and Applications
  • Advanced X-ray and CT Imaging
  • Radiation Therapy and Dosimetry
  • Laser-induced spectroscopy and plasma
  • Diamond and Carbon-based Materials Research
  • Nuclear reactor physics and engineering
  • Geological and Geochemical Analysis
  • Radiation Detection and Scintillator Technologies
  • Nuclear and radioactivity studies

Brigham Young University
2023-2024

Massachusetts Institute of Technology
1956

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. Using an incoming pump beam 22 keV, we observe simultaneous, elastic emission down-converted photon pairs generated in a diamond crystal. The are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed measuring time-energy correlations detector signal, where within energy window ranging from 10 to 12 keV only observed short...

10.1016/j.rinp.2024.107328 article EN cc-by-nc-nd Results in Physics 2024-01-06

Two liquid scintillation type neutron detectors with efficiencies of the order 5% for counting 130-Mev neutrons have been studied. A fairly monoenergetic source was obtained from photodisintegration deuterons. Estimates were made counters as a function bias. Experiments indicate: (1) an appreciable effect products reactions carbon; (2) efficiency can be more accurately predicted small counter although behavior large qualitatively predicted; (3) attenuation due to lead shield in beam depends...

10.1063/1.1715492 article EN Review of Scientific Instruments 1956-03-01

This paper outlines the use of charge detection mass spectrometry to simultaneously measure and micron-sized particles. In a flow-through instrument, was achieved through induction onto cylindrical electrodes that connect differential amplifier. Mass determined by particle acceleration under influence an electric field. Particles ranging from 30 400 fg (3 7 µm diameter) were tested. The detector design can within 10% accuracy for particles up 620 with total 500e− 56 ke−. range are expected...

10.1063/5.0131941 article EN Review of Scientific Instruments 2023-03-01

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. Using an incoming pump beam 22 keV, we observe simultaneous, elastic emission down-converted photon pairs generated in a diamond crystal. The are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed measuring time-energy correlations detector signal, where within energy window ranging from 10 to 12 keV only observed short...

10.48550/arxiv.2309.13197 preprint EN other-oa arXiv (Cornell University) 2023-01-01

We measured correlated X-ray photons from parametric down conversion as a means of creating entangled X-rays. Using Laue diffraction geometry, we the efficiency this process single crystal diamond samples.

10.1364/3d.2023.jw2a.40 article EN 2023-01-01
Coming Soon ...