Tomaz Puga Leivas

ORCID: 0000-0003-2547-7553
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Bone health and osteoporosis research
  • Bone fractures and treatments
  • Orthopaedic implants and arthroplasty
  • Lower Extremity Biomechanics and Pathologies
  • Spinal Fractures and Fixation Techniques
  • Sports injuries and prevention
  • Hydrogen embrittlement and corrosion behaviors in metals
  • Metal and Thin Film Mechanics
  • Total Knee Arthroplasty Outcomes
  • Knee injuries and reconstruction techniques
  • Corrosion Behavior and Inhibition
  • Hip disorders and treatments
  • Spine and Intervertebral Disc Pathology
  • Medical Imaging and Analysis
  • Bone and Joint Diseases
  • Shoulder Injury and Treatment
  • Orthopedic Surgery and Rehabilitation
  • Dental Implant Techniques and Outcomes
  • Digital Imaging in Medicine
  • Facial Trauma and Fracture Management
  • Mechanical Engineering and Vibrations Research
  • Bone health and treatments
  • Anatomy and Medical Technology
  • Infection Control and Ventilation
  • Bone Metabolism and Diseases

Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
1997-2020

Universidade de São Paulo
1995-2017

Hospital de Clínicas
2002

Governo do Estado de Mato Grosso
2001

Associação Paulista de Medicina
2000

Sociedade Brasileira de Ortopedia e Traumatologia
2000

To perform a comparative analysis of the effects platelet-rich plasma and centrifuged bone marrow aspirate on induction healing in rabbits.

10.1590/s1807-593220110007000018 article EN DOAJ (DOAJ: Directory of Open Access Journals) 2011-01-01

Osteoporosis is defined by the National Institutes of Health as a skeletal disorder characterized compromised bone strength, increasing fracture risk. Samples vertebral cancellous were extracted from human cadavers T12 region. The comparative pre-selection into three groups was performed using calcaneal ultrasonometry and evaluated image analysis: microtomography, X-ray diffraction, optical microscopy e scanning electron microscopy. results showed, for diseased bone, degradation, reduction...

10.1016/j.proeng.2013.05.087 article EN Procedia Engineering 2013-01-01

Introduction Biomechanical assessment of trabecular bone microarchitecture contributes to the evaluation fractures risk associated with osteoporosis and plays a crucial role in planning preventive strategies. One most widely clinical technics used for diagnosis by health professionals is dual-energy X-ray absorptiometry (DEXA). However, doubts about its accuracy motivate introduction congruent technical analysis such as calcaneal ultrasonometry (Quantitative Ultrasonometry - QUS). Methods...

10.1590/2446-4740.04116 article EN Research on Biomedical Engineering 2017-06-01

The term crystal structure is understood as a set of atoms periodically distributed in space, forming lattice. composite material, bone, contains an organic part consisted collagen and inorganic predominantly hydroxyapatite crystals, having the molecular formula Ca10(PO4)6(OH)2 its unit cell. can indicate trabecular bone quality, by identification crystallite size, microhardness, microstrain ratio calcium phosphorus bones three types: normal, osteopenic or osteoporotic. Osteoporosis defined...

10.1016/j.proeng.2015.07.003 article EN Procedia Engineering 2015-01-01

Proteins are widely used in solutions order to simulate the physiological fluids and study corrosion mechanisms. The present work appraised ASTM F 139 austenitic stainless steel (SS), employed prostheses manufacture, engraved by a nanosecond laser beam, using phosphate buffered solution with 10 g/L of bovine serum albumin (PBS + BSA). Due complexity interaction between protein biomaterial, it was necessary use higher BSA concentrations, however, similar those found human serum....

10.1016/s1452-3981(23)08054-9 article EN cc-by-nc-nd International Journal of Electrochemical Science 2014-07-01

Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer 10 pairs femurs and tibias. A central hole 3.2 was drilled each specimen. The tapped, a 4.5 screw inserted outer surface. montage submitted to push-out testing up complete strip threads. thickness rupture load measured, shear stress calculated. results grouped according segment which specimen obtained. showed that cortex holding power is dependent on site. Additionally, diaphyseal tissue...

10.1590/s0041-87811999000600003 article EN Revista do Hospital das Clínicas 1999-12-01

Albumin is the most abundant protein found in human serum and sinovial fluids. Investigations on its effects corrosion resistance of metallic biomaterials have led to controversial conclusions. The BSA (bovine albumin) concentration used studies below usual physiological This possibly reason for lack agreement conclusions reported literature. aim this study evaluate effect albumin susceptibility ASTM F139 austenitic stainless steel (SS) fabrication orthopedic implants, specifically areas...

10.1016/s1452-3981(23)07938-5 article EN cc-by-nc-nd International Journal of Electrochemical Science 2014-05-01

Abstract In this study, the measurement of concentration and size particles identification their sources were carried out at five orthopedic surgeries. The aerosol particle distribution, ranging from 0.3 μm–10 μm, measured related to type indoor activity. handling surgical linen gowns, patient, use electrosurgical apparatus, a bone saw, equipment, cleaning room identified as most important particles, with each these activities posing different risks health patients workers. results showed...

10.1080/10789669.2012.705572 article EN HVAC&R Research 2012-08-01

Com a finalidade de se comparar as propriedades mecânicas do ligamento da patela e tendão calcâneo foram realizados ensaios tração em material obtido 25 cadáveres humanos. A idade dos doadores foi 58 ± 14 anos (33-85), sendo 19 (76%) masculinos 6 (24%) femininos, 23 brancos (92%) dois negros (8%). Os materiais testados seus 10 mm centrais, com velocidade aplicação carga 30 mm/min. Foi obtida área secção corpos prova para que fossem estudadas estruturais materiais. Foram seguintes variáveis:...

10.1590/s1413-78522004000300001 article PT cc-by Acta Ortopédica Brasileira 2004-09-01

Com o objetivo de avaliar enfraquecimento causado pela confecção janela óssea cortical, os autores confeccionaram uma circular no osso cortical da diáfise oito fêmures carcaças cães e quadrada nos pares destes fêmures, com diagonal semelhante ao diâmetro contralateral. As peças anatômicas foram submetidas a teste tensão torcional em máquina ensaios mecânicos; obtendo-se torque máximo rigidez à torção. Os resultados mostraram que, para fêmur circular, médio foi 13,65 ± 5,12 Nm, média 1,18...

10.1590/s1413-78522002000200006 article PT cc-by Acta Ortopédica Brasileira 2002-06-01

Com o objetivo de avaliar a rigidez do ligamento cruzado anterior e dos enxertos preparados para sua reconstrução partir da porção central patelar tendões músculos semitendíneo grácil duplos, oriundos mesmos joelhos, autor utiliza 20 joelhos cadáveres humanos, frescos, todos masculinos, com idade média 32,2 ± 8,9 anos, variando 17 47 anos. As estruturas analisadas foram submetidas três ensaios mecânicos tração, intervalos 10 minutos recuperação, em máquina Kratos K-5002 (eletromecânica),...

10.1590/s1413-78522001000200004 article PT cc-by Acta Ortopédica Brasileira 2001-06-01

Foram estudados, do ponto de vista mecânico, a rigidez e os pontos críticos um implante para fixação interna da coluna lombossacra. Aplicou-se o sobre modelo madeira simulando segmento lombossacro coluna. Realizamos sete ensaios flexo-compressão, axial, radial ensaio destrutivo. Os resultados demonstraram que foi eficiente seguro uso em seres humanos.

10.1590/s1413-78522000000300003 article PT cc-by Acta Ortopédica Brasileira 2000-09-01

Análise comparativa das alterações nos fluxos de tensão do joelho nas próteses totais e unicompartimentais cimentadas. Estudo experimental em dez cadáveres humanos. Os autores comparam as fêmur distal da tíbia proximal provocadas pelas total unicompartimental cimentadas joelho, por meio extensometria elétrica 10 Utilizam um dispositivo mecânico para adaptação peças anatômicas à máquina ensaios mecânicos Kratos 5002. Concluem: 1) A prótese mantém o padrão distribuição cargas no terço fêmur;...

10.1590/s1413-78522003000300001 article PT cc-by Acta Ortopédica Brasileira 2003-08-01

Fractures resulting from wear and fatigue process have been identified as the main causes of failure in biomaterials, especially implants that act place bone or other hard tissue, they are subject to conditions involving severe cyclic loadings. In biomaterialscase, types failures mentioned above must also be evaluated under effect degradation corrosion, due direct contact with body fluids. The present research analyzed induced by corrosion fracture an orthopaedic implant for total knee...

10.4028/www.scientific.net/msf.1012.471 article EN Materials science forum 2020-10-01

Introdução: o tratamento cirúrgico de pacientes com fraturas do processo odontoide tem sido controverso. As principais técnicas cirúrgicas para segmento C1-C2 incluem além da artrodese cervical (aramagem tipo Gallie, parafusos transarticulares e aramagem 88), a fixação direta parafuso no odontoide. Objetivo: comparar estabilidade mecânica destes quatro tipos osteossínteses atlantoaxial (C1-C2). Metodologia: vinte segmentos atlantoaxiais cadáveres humanos adultos forampreparados 2 Anderson...

10.9771/cmbio.v21i2.38566 article PT Revista de Ciências Médicas e Biológicas 2022-10-31

A relevância do estudo dos processos en­volvidos na recuperacao da fratura ossea bem como a influencia de fatores que acelerem repa­racao e indiscutivel, visto um fator incapacitante. Nosso principal objetivo foi anali­sar os efeitos exercicio fisico cronico sobre velocidade consolidacao resistencia esforcos deformantes. Para isso realizamos uma osteotomia no terco superior tibia direita, atra­ves micro-furadeira para uniformizar le­sao. O treinamento consitiu em natacao 1 h por dia com...

10.12820/rbafs.v.1n2p59-64 article PT Revista Brasileira de Atividade Física & Saúde 1995-01-01
Coming Soon ...