Chao Gao

ORCID: 0000-0003-3336-9819
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High voltage insulation and dielectric phenomena
  • Thermal Analysis in Power Transmission
  • Power Transformer Diagnostics and Insulation
  • High-Voltage Power Transmission Systems
  • Lightning and Electromagnetic Phenomena
  • Geotechnical Engineering and Underground Structures
  • Aerosol Filtration and Electrostatic Precipitation
  • Ultrasonics and Acoustic Wave Propagation
  • Power Systems and Technologies
  • Electrical Fault Detection and Protection
  • Non-Destructive Testing Techniques
  • Fiber-reinforced polymer composites
  • Epoxy Resin Curing Processes
  • HVDC Systems and Fault Protection
  • Smart Materials for Construction
  • Power Line Inspection Robots
  • Mechanical Behavior of Composites
  • Polymer composites and self-healing
  • Mechanical stress and fatigue analysis
  • Geophysical Methods and Applications
  • Smart Grid and Power Systems
  • Nuclear and radioactivity studies
  • Microwave-Assisted Synthesis and Applications
  • Material Properties and Processing
  • Asphalt Pavement Performance Evaluation

China Southern Power Grid (China)
2014-2025

Quzhou University
2024

Huazhong University of Science and Technology
2024

Inner Mongolia Electric Power (China)
2024

Beihang University
2019-2022

Electric Power Research Institute
2010-2021

National Institute for Radiological Protection
2017

Nanjing University of Posts and Telecommunications
2016

Tsinghua University
2015

Changsha University of Science and Technology
2013

The dielectric loss characteristics of epoxy resin, as a critical insulating material in high-frequency transformers, are essential to the performance and safety transformers. This paper explores mechanism epoxy/anhydride curing systems through molecular dynamics simulations, particularly focusing on impact segmental motion loss. study reveals that probability density distribution speeds various segments cross-linked network follows Maxwell-Boltzmann distribution. increased rigidity agent...

10.1117/12.3045339 article EN other-oa 2025-01-15

Operating experience shows that residual DC voltage remains in GIS bus bar for a long time after opening of disconnectors. This will not only cause accumulation charges and contaminants on the insulator surface, but also easily lead to motion free metallic particles SF6 gas gap, weakening insulation ability GIS. At disconnectors reclosing, impulse could be generated superimpose pre-existing voltage. As result, under combined impulse. paper experimentally studies characteristics lightning It...

10.1109/tdei.2017.006535 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2017-04-01

The safety and stability of power systems are seriously threatened by the decay-like fracture composite insulators. This paper analyzes aging characteristics (physical properties, NMR, FTIR) silicone rubber sheds fractured insulator. same V-string insulator a new used for comparison. study shows that sheds’ degradation is concentrated on side with heavy pollution. physical properties (appearance, pollution, hardness, hydrophobicity) high voltage end decrease significantly compared to other...

10.3390/polym14163424 article EN Polymers 2022-08-22

The power outage caused by decay-like fracture of composite insulators significantly impacts the grid. In this paper, a fractured insulator 500 kV transmission line is taken as research object. detailed observation core rod and silicone rubber housings, discharge results, temperature rises, electric field distribution are obtained. (a) has abnormal heating on exposed sheath surface, ambient humidity influence rise. (b) It proposed that one most obvious characteristics rise (such T > 50°C, ΔT...

10.1049/gtd2.12584 article EN cc-by IET Generation Transmission & Distribution 2022-08-22

Contamination of free conducting particles is a major threat to gas insulated systems. In HVDC GIL, can be even more harmful due the fact that easily cross gap under DC voltage and distort electric field. systems, impulse overvoltage generated superimposed on operating voltage. As result, GIL will experience this paper, behavior in observed breakdown characteristics particle contaminated voltages are studied. Two motion patterns mainly found: bouncing firefly motions. Particles tend near...

10.1109/tdei.2018.007053 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2018-08-01

The past and recent investigations show that front time of switching overvoltage waveforms in Ultra High Voltage (UHV) system long distance transmission are mostly wave exceeding 1000 μs. impulse voltage has been deviated from the critical time. This paper is involved with breakdown characteristics external insulation design under UHV system. All Tests were performed on an outdoor test site at altitude 2100 m, China Southern Power Grid Co. Ltd. (CSG). Breakdown rod-plane actual size...

10.1109/tdei.2014.6832240 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2014-06-01

A large density difference of a basin-type insulator in gas-insulated metal-enclosed switchgear (GIS) weakens its mechanical strength, which will threaten the safe and stable operation GIS. In this article, an ultrasonic nondestructive testing method for uniformity GIS insulators was proposed. First, seven standard samples with different Al <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O...

10.1109/tim.2021.3107053 article EN IEEE Transactions on Instrumentation and Measurement 2021-01-01

Thermal stress of gas-insulated metal-enclosed switchgear (GIS) basin-type insulators weaken its mechanical properties, which will threaten the safe and stable operation GIS. In this article, simulation experiment thermal in a 252-kV GIS insulator were carried out. An acoustic-distance difference method based on ultrasonic critical refraction longitudinal wave (ultrasonic <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math...

10.1109/tim.2021.3137547 article EN IEEE Transactions on Instrumentation and Measurement 2021-12-22

The multifactor accelerated aging test is an important means to predict the lifetime of gas-insulated switchgear (GIS) O-ring seals, while leakage rate (LR) a potential index for failure evaluation. This article proposed three-factor platform and system (LTS) GIS seal rings. factors are thermal, mechanical compression, pressured SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas. pressure vessel (PAV) can be filled with various gases...

10.1109/tim.2021.3053983 article EN IEEE Transactions on Instrumentation and Measurement 2021-01-01

This paper deals with the air gap insulation of ±800 kV DC transmission systems under composite and switching impulse voltage. The gaps studied were representative line, as rod-to-plane conductor-to-tower gaps. flashover voltages at an altitude 2100 m determined for a pure impulse. It is found that there are clear increase in voltage both gaps, compared those only was applied. From test results, increases by 17-23%in 5-10% gap, when 800 pre-stressed. standard deviations have little obvious...

10.1109/tdei.2014.004003 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2014-10-01

In this work, we propose an all-dielectric frequency selective surface (FSS) composed of periodically placed high-permittivity dielectric resonators and a three-dimensional (3D) printed supporter. Mie resonances in the offer strong electric magnetic dipoles, quadrupoles, higher order terms. The re-radiated fields by these multipoles interact with incident fields, which leads to total reflection or transmission some special bands. measured results fabricated FSS demonstrate stopband...

10.1088/1674-1056/25/6/068101 article EN Chinese Physics B 2016-06-01

The chalking of composite insulators is referred to a kind abnormal aging the silicone rubber sheds.It has serious adverse effects on long-term operation insulators, but mechanism behind its generation and development remains unclear.In order deeply understand phenomenon insulator chalking, this paper took chalked operating extra-high voltage (EHV) AC 500 kV as samples for research.Appearance inspection, hydrophobicity test tensile stress were performed determine change their surface...

10.1109/access.2022.3140764 article EN cc-by-nc-nd IEEE Access 2022-01-06

In order to further utilize the transmission line cooridor, meanwhile, achieve a relatively friendly electromagnetic environment, composite cross arm is developed and employed in system. The electric field distribution as well electromagentic environment of deserves detailed in-depth study verify its performance. this research, three-dimension (3D) finite element method (FEM) was calculate arm. characterized by intensity on ground, radio interference audible noise these parameters were...

10.1109/ceidp.2015.7352045 article EN 2022 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) 2015-10-01

As one of the key components circuit breaker operating mechanism, relay can experience performance degradation due to harsh environmental factors, such as salt spray, during operation, which ultimately affect normal operation and threaten safe stable power system. To effectively evaluate condition in spray environments over long term, this study conducted accelerated aging experiments on a certain model auxiliary switch under conditions using an existing test platform. The relay’s pull-in...

10.3390/en16134843 article EN cc-by Energies 2023-06-21
Coming Soon ...