Radhakrishna G. Pillai

ORCID: 0000-0003-3672-8768
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Concrete Corrosion and Durability
  • Concrete and Cement Materials Research
  • Corrosion Behavior and Inhibition
  • Structural Behavior of Reinforced Concrete
  • Infrastructure Maintenance and Monitoring
  • Innovative concrete reinforcement materials
  • Smart Materials for Construction
  • Concrete Properties and Behavior
  • Recycled Aggregate Concrete Performance
  • Structural Engineering and Vibration Analysis
  • Green IT and Sustainability
  • Microbial Applications in Construction Materials
  • ICT Impact and Policies
  • Magnesium Oxide Properties and Applications
  • Big Data and Business Intelligence
  • Structural Health Monitoring Techniques
  • Structural Load-Bearing Analysis
  • Probabilistic and Robust Engineering Design
  • Geotechnical Engineering and Underground Structures
  • Information Systems Theories and Implementation
  • Economic Growth and Development
  • Grouting, Rheology, and Soil Mechanics
  • Advanced Surface Polishing Techniques
  • Innovative Approaches in Technology and Social Development
  • Fire effects on concrete materials

Indian Institute of Technology Madras
2014-2024

Indian Institute of Management Kozhikode
2013-2021

Purdue University West Lafayette
2014

California State University, San Bernardino
2013

Texas A&M University
2009-2010

Ashland (United States)
2009-2010

Marathon Oil (United States)
2009-2010

Mitchell Institute
2007

First Name is required invalid characters Last Email Address Invalid

10.14359/56461 article EN ACI Materials Journal 2009-01-01

First Name is required invalid characters Last Email Address Invalid

10.14359/14303 article EN ACI Materials Journal 2005-01-01

Cloud computing is emerging as a powerful paradigm with its aim of efficient resource utilization and contribution to Green IT. However, the decision shifting cloud always remains risky from customer's perspective considering benefits they would attain by doing so. The extant research on focuses more technical aspects like security, quality, efficiency etc. adoption at infancy stage. Therefore, this paper attempts come up model analyze cost decide upon adoptability computing. It takes into...

10.58729/1941-6679.1017 article EN Journal of international technology and information management 2013-11-08

About a decade of research carried out at IIT Madras on cementitious systems has shown that the partial replacement portland cement with supplementary materials (SCMs) benefits as well limitations. The SCMs do not adversely affect long-term compressive strength and drying shrinkage concretes, though there may be some compromise in workability resistance against plastic cracking. Through assessment chloride ingress rate concrete threshold steel, it is evident use could significantly enhance...

10.21041/ra.v10i2.477 article EN cc-by Revista ALCONPAT 2020-04-30

First Name is required invalid characters Last Email Address Invalid

10.14359/12959 article EN ACI Materials Journal 2003-01-01

The presence of air voids, moisture, and chlorides inside tendons or ducts was cited as a reason for the early age strand corrosion failure in Mid-bay, Sunshine Skyway, Niles Channel posttensioned (PT) bridges Florida, United States. Although rare, these incidents call frequent inspection structural reliability assessment PT exposed to moisture chlorides. This paper develops presents probabilistic capacity models that are needed assess such recommends time frequency inspection. A total 384...

10.1061/(asce)em.1943-7889.0000021 article EN Journal of Engineering Mechanics 2009-03-07

First Name is required invalid characters Last Email Address Invalid

10.14359/12988 article EN ACI Materials Journal 2004-01-01

Posttensioned (PT) bridges are used on major thoroughfares because they economical structures for traversing long spans. Special inspections of these have revealed corrosion the strands at void locations in tendons. The integrity has significant influence safety bridges. Inspections indicate that many ducts (parts tendon is supposed to protect from exposure aggressive environments) cracked and grout holes vents opened, allowing direct ingress moisture chlorides. This paper presents a...

10.1061/(asce)st.1943-541x.0000991 article EN Journal of Structural Engineering 2014-05-23
Coming Soon ...