Zheng Xu

ORCID: 0000-0003-3968-414X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced MRI Techniques and Applications
  • NMR spectroscopy and applications
  • Electrical and Bioimpedance Tomography
  • Atomic and Subatomic Physics Research
  • Advanced NMR Techniques and Applications
  • Non-Destructive Testing Techniques
  • High voltage insulation and dielectric phenomena
  • Flow Measurement and Analysis
  • High-Voltage Power Transmission Systems
  • HVDC Systems and Fault Protection
  • Geophysical and Geoelectrical Methods
  • Magnetic Field Sensors Techniques
  • Nuclear Physics and Applications
  • Geophysical Methods and Applications
  • Microfluidic and Bio-sensing Technologies
  • Ultrasonics and Acoustic Wave Propagation
  • Advanced DC-DC Converters
  • Multilevel Inverters and Converters
  • Advanced Sensor and Control Systems
  • Magneto-Optical Properties and Applications
  • Antenna Design and Analysis
  • Power System Optimization and Stability
  • Advanced Measurement and Detection Methods
  • Aerosol Filtration and Electrostatic Precipitation
  • Medical Imaging Techniques and Applications

Chongqing University
2016-2025

Shenyang University of Chemical Technology
2024

Zhejiang University
2002-2024

State Grid Hebei Electric Power Company
2024

Economic Research Institute
2024

Wuxi Wind Power Design and Research Institute
2023

Hiroshima University
2021

Nottingham Trent University
2014

Dalian University of Technology
2006

Nanjing University
1994-1996

The detection of adulteration in edible oils is a concern the food industry, especially for higher priced virgin olive oils. This article presents low field unilateral nuclear magnetic resonance (NMR) method oil that can be performed through sealed bottles providing non-destructive screening technique. Adulterations an extra with different percentages sunflower and red palm were measured commercial instrument, profile NMR-Mouse. NMR signal was processed using 2-dimensional Inverse Laplace...

10.3390/s140202028 article EN cc-by Sensors 2014-01-24

<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Objective:</i> Passive shielding is usually applied to block electro-magnetic interference (EMI) for portable very-low field MRI scanners, but it goes against the mobility of scanners. Here, reference channel-based active EMI suppression (AES) system was proposed discard them. xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</i> Different from existing studies, this work started with...

10.1109/tbme.2022.3170450 article EN IEEE Transactions on Biomedical Engineering 2022-04-26

This paper proposes a multi-channel magnetic induction tomography measurement system for biological conductivity imaging in human brain model. A hemispherical glass bowl filled with salt solution is used as the model; meanwhile, agar blocks of different are placed to simulate intracerebral hemorrhage. The excitation and detection coils fixed co-axially, axial gradiometer coil order cancel primary field. On outer surface bowl, 15 sensor units arrayed two circles parts, single unit canceling...

10.1088/0967-3334/30/6/s12 article EN Physiological Measurement 2009-06-01

Burn depth assessment in clinics is still inaccurate because of the lack feasible and practical testing devices methods. Therefore, this process often depends on subjective judgment burn surgeons. In study, a new unilateral magnetic resonance imaging (UMRI) sensor equipped with 2D gradient coil system was established, we attempted to assess burns using nuclear devices. A reduced Halbach magnet utilized generate field that relatively homogeneous target plane suitable view for spatial...

10.3390/s17030526 article EN cc-by Sensors 2017-03-06

The use of a close-fitting roughly head-shaped volume coil for MRI (magnetic resonance imaging) has the merit improving filling factor and thus SNR (signal-to-noise ratio) from brain. However, surface RF follows that head which makes it difficult to determine an optimal winding pattern. We describe here new method optimize with objective maximizing its RF-magnetic-field homogeneity operation at ultra-low magnetic field (6.5 mT, 276 kHz).The approach consists FEM (finite-element-method)...

10.1109/tbme.2020.3002077 article EN publisher-specific-oa IEEE Transactions on Biomedical Engineering 2020-06-12

The important role of the distribution cabinets in power system makes voltage monitoring them great significance. However, traditional measurement methods (e.g., electromagnetic transformers) have defects such as galvanic contact and magnetic saturation. Under this background, paper proposes a noncontact (NC) method for three-phase busbar low-voltage cabinets. Injecting high-frequency calibrating signal into capacitive coupling network coupled sensor to achieve self-calibration sensor....

10.1109/tim.2024.3364266 article EN IEEE Transactions on Instrumentation and Measurement 2024-01-01

As the researches of electric impedance tomography (EIT) applications in medical examinations deepen, we attempt to produce visualization 3D images human bladder. In this paper, a planar electrode array system will be introduced as measuring platform and series feasible methods are proposed evaluate simulated volume bladder avoid overfilling. The combined regularization algorithm enhances spatial resolution presents distinguishable sketch disturbances from background, which provides us with...

10.1155/2012/528096 article EN Computational and Mathematical Methods in Medicine 2012-01-01

The aging of a silicone rubber insulator threatens the safety power grid. An accurate estimation status is necessary for taking precautions against insulation failure. In this paper, we propose novel unilateral nuclear magnetic resonance (NMR) method to quantify degradation attributed aging. First, NMR sensor was designed specifically transverse relaxation time (T <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) measurement. static...

10.1109/jsen.2015.2499765 article EN IEEE Sensors Journal 2015-11-11

In a companion paper, we have obtained the closed-form solutions to stress and strain fields of two-dimensional Eshelby inclusion. The current work is concerned with complementary formulation displacement. All formulae are derived in explicit closed-form, based on degenerate case three-dimensional (3D) ellipsoidal A benchmark example provided validate present analytical solutions. conjunction our previous study, complete elasticity solution classical elliptic cylindrical inclusion hence...

10.1115/1.4036820 article EN Journal of Applied Mechanics 2017-05-24

This study presents a high-performance single-sided portable nuclear magnetic resonance (NMR) sensor. The magnet array, which is composed of five identical cuboid permanent blocks and two passive shimming sheets, generates highly uniform B_{

10.3233/jae-140123 article EN International Journal of Applied Electromagnetics and Mechanics 2015-03-01

Silicone rubber insulators (SRIs) play an important role in high-voltage power transmission lines. Given that SRIs critically threaten the safe operation of grid, quantitatively assessing aging status situ is crucial. In this article, a portable unilateral magnetic resonance (UMR) sensor with U-shaped magnet structure and its measuring circuit were designed for nondestructive detection situ. First, optimization efficiency was improved through uniform design method. Then, planar radio...

10.1109/tim.2020.3011087 article EN IEEE Transactions on Instrumentation and Measurement 2020-07-22

The sensor determines the basic performance of nuclear magnetic resonance (NMR) logging-while-drilling (LWD) system. However, electromagnetic calculation and structure optimization are complicated difficult. In this study, we proposed an effective design method for inside-out NMR LWD from perspective field. First, a region interest (ROI) was set first, static field strength range in ROI corresponding to ideal operating frequency bandwidth defined as sensitive region, magnet system optimized...

10.1109/tim.2022.3169572 article EN IEEE Transactions on Instrumentation and Measurement 2022-01-01

This paper analyzes the dc line fault transient stability characteristics of AC/DC power systems based on three different modular multilevel converter high direct current (MMC-HVDC) configurations. The first configuration is half bridge sub-module MMC (H-MMC) HVDC configuration, which clears faults by tripping ac circuit breakers. Voltage source converters (VSC) with clearance ability constitute second configuration. A line-commutated convener (LCC) and hybrid ability, named LCC-diode-MMC...

10.1109/pesgm.2015.7285663 article EN 2015-07-01

Objective. The aim of this study is to investigate continuous blood pressure waveform estimation from a plethysmography (PPG) signal, thus providing more human cardiovascular status information than traditional cuff-based methods.Approach. proposed method utilizes the feature extraction ability convolution neural network estimate (BP) PPG signals without need for analysis and signal extraction.Main results. achieved mean absolute errors standard deviations 2.55 ± 3.92 mmHg systolic BP (SBP),...

10.1088/1361-6579/acd164 article EN Physiological Measurement 2023-04-28
Coming Soon ...