Dexin Zou

ORCID: 0000-0003-4993-9425
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Pelvic and Acetabular Injuries
  • Spinal Fractures and Fixation Techniques
  • Hip disorders and treatments
  • Pregnancy-related medical research
  • Spine and Intervertebral Disc Pathology
  • Nerve injury and regeneration
  • Hip and Femur Fractures
  • Turbomachinery Performance and Optimization
  • Thermodynamic and Exergetic Analyses of Power and Cooling Systems
  • Anesthesia and Neurotoxicity Research
  • Advanced Combustion Engine Technologies
  • Medical Imaging and Analysis
  • Management of metastatic bone disease
  • Vascular Procedures and Complications
  • Advanced Thermodynamic Systems and Engines
  • Combustion and flame dynamics
  • Signaling Pathways in Disease
  • Orthopaedic implants and arthroplasty
  • Education, Safety, and Science Studies
  • Cardiac Ischemia and Reperfusion
  • Diverse Approaches in Healthcare and Education Studies
  • Scoliosis diagnosis and treatment
  • Spinal Cord Injury Research
  • Video Surveillance and Tracking Methods
  • Neuroblastoma Research and Treatments

Yantaishan Hospital
2013-2024

Qiqihar University
2024

Binzhou Medical University
2023-2024

Binzhou University
2023

Central Hospital of Zibo
2021

Harbin Engineering University
2021

Nanjing Sport Institute
2018

Shenyang Sport University
2018

Washington University in St. Louis
1993-2005

University of Wisconsin–Madison
1993

When ships sail on the sea, changes of ship motion attitude presents characteristics nonlinearity and high randomness. Aiming at problem low accuracy roll angle prediction by traditional algorithms single neural network model, a method based bidirectional long short-term memory (Bi-LSTM) temporal pattern attention mechanism (TPA) combined deep learning model is proposed. Bidirectional extracts time features from forward reverse series, patterns output state that are beneficial to prediction,...

10.3390/jmse9040387 article EN cc-by Journal of Marine Science and Engineering 2021-04-06

In vitro calf spine testing was performed in flexion, rotation, and axial load, using a vertebral body corpectomy anterior iliac crest bone grafting model. Anterior spinal fixation devices then were sequentially tested, stiffness, torsional flexural strain determined. The constructs tested the Contoured Spinal Piate (CASP), Kaneda device, Kostuik-Harrington device (KH), Texas Scottish Rite Hospital (TSRH) screw construct. torsion, returned stability to that of intact spine. unstable torsion....

10.1097/00007632-199303010-00016 article EN Spine 1993-03-01

Abstract Objective The purpose of this research is to evaluate the risk factors and incidence pulmonary cement embolism (PCE) during percutaneous vertebroplasty (PVP) or kyphoplasty (PKP) for osteoporotic vertebral compression fractures (OVCFs) based on postoperative computed tomography (CT). Methods A total 2344 patients who underwent PVP PKP due OVCFs in our spine center were analyzed retrospectively. According detection CT, divided into two groups: group (PCE group) non-pulmonary (NPCE...

10.1186/s13018-021-02472-9 article EN cc-by Journal of Orthopaedic Surgery and Research 2021-05-13

To conduct radiologic anatomical study on the relation between S1 sacroiliac screws' entry points and route of pelvic outer superior gluteal artery branches with aim to provide basis technical reference for avoidance damage during horizontal screw placement.Superior CTA (CT angiography) vascular imaging 74 healthy adults (37 women 37 men) was done 128-slice spiral CT (computed tomography). The attendant-measuring software used portray "safe bony entrance area" (hereinafter referred as "Safe...

10.1186/s13018-018-0713-5 article EN cc-by Journal of Orthopaedic Surgery and Research 2018-01-18

The proliferation and migration of Schwann cells contribute to axonal outgrowth functional recovery after peripheral nerve injury. Previously, several microRNAs were abnormally expressed injury they played important roles in regeneration. However, the role underlying mechanism miR-34a remain largely unknown. levels contactin-2 (CNTN2) detected by quantitative real-time PCR. 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide transwell assays used examine cell migration,...

10.1097/wnr.0000000000001539 article EN Neuroreport 2020-10-08

The present study aimed to evaluate the clinical efficacy of bilateral pedicle cement anchoring technique combined with postural reduction in percutaneous vertebroplasty (PVP) for Kümmell disease. For this purpose, a retrospective was performed on 18 patients disease who between January 2018 and June 2021 underwent PVP. Pre‑ post‑operative bone mineral density, injected volume, visual analogue scale (VAS) values, Oswestry disability index (ODI) scores, Cobb angle measurements anterior...

10.3892/etm.2023.12090 article EN Experimental and Therapeutic Medicine 2023-06-30

Abstract Background To compare the mechanical characteristics of a percutaneous superior pubic intramedullary screw, bridging plate and screw-rod system anterior ring for treatment unilateral vertical fractures to provide reference clinical application. Methods A finite element model pelvic injury (unilateral fracture) was produced. The were fixed with their combinations in 5 types models. fracture stabilities under vertical, bilateral anterior-posterior load quantified compared based on...

10.1186/s12891-020-03604-8 article EN cc-by BMC Musculoskeletal Disorders 2020-09-04

Bromodomain-containing protein 4 (BRD4) plays an important role in gene transcription a variety of diseases, including inflammation and cancer. However, the mechanism by which BRD4 inhibitors bind selectively to its bromodomain 1 (BRD4-BD1) 2 (BRD4-BD2) remains unclear. Studying interaction between will provide new ideas for drug development disease treatment. To explore molecular selective binding three novel phenoxypyridone Cpd11, Cpd14, Cpd23 BRD4-BD1 BRD4-BD2, respectively, docking,...

10.1080/1062936x.2024.2447071 article EN SAR and QSAR in environmental research 2024-12-01

This paper presents transient-flow component models for the prediction of transient response gas turbine cycles. The application is to predict a small solar-powered regenerative gas-turbine engine with centrifugal impellers. sizes are similar those under consideration Space Station, but can easily be generalized other applications axial or mixed-flow turbomachinery. New propagation arbitrary transients in impellers developed. These coupled heat exchangers, receiver and radiator. based on...

10.1115/1.1806450 article EN Journal of Engineering for Gas Turbines and Power 2005-06-24

Instantaneous-response and transient-flow component models for the prediction of transient response gas turbine cycles are presented. The based on applications principles conservation mass, energy, momentum. coupled to simulate system thermodynamic behavior, used predict a closed-cycle regenerative Brayton cycle. Various transients simulated using: instantaneous-response turbomachinery with heat-exchanger models; models. sizes comparable those solar-powered Space Station (radial...

10.1115/1.1806449 article EN Journal of Engineering for Gas Turbines and Power 2005-01-01

To compare the breakage risk of lengthened sacroiliac screws and ordinary to treat unilateral vertical sacral fractures provide a reference for clinical application.A finite element model Tile C pelvic ring injury (unilateral type Denis II fracture sacrum) was produced. The were fixed with screw in 6 types models. maximal von Mises stresses stress distributions two kinds when standing on both feet measured compared.The less than that screw. Compared screw, distribution more homogeneous.The...

10.1186/s12891-022-05898-2 article EN cc-by BMC Musculoskeletal Disorders 2022-11-04

Ischemic preconditioning or postconditioning has been shown to have neuroprotective effect on cerebral ischemia, but it not studied in peripheral nerve injury. In this study, a rat model of sciatic transection was established, and subjected three cycles ischemia for 10 minutes + reperfusion minutes, once day. After ischemic postconditioning, serum insulin-like growth factor 1 expression increased; Schwann cell myelination sensory function motor were restored. These findings indicate that can...

10.4103/1673-5374.228733 article EN cc-by-nc-sa Neural Regeneration Research 2018-01-01

This paper presents instantaneous-response and transient-flow component models for the prediction of transient response gas turbine cycles. The are based on applications principles conservation mass, energy, momentum. coupled to simulate system thermodynamic behavior, used predict a closed-cycle regenerative Brayton cycle. Various transients simulated using: turbomachinery with heat-exchanger models; models. sizes comparable those under consideration solar-powered Space Station (radial...

10.1115/93-gt-136 article EN 1993-05-24

Objective To compare the biomechanical characteristics of lengthened sacroiliac screw and long fixated in different ways for treatment central vertical sacral fractures to provide reference clinical practice. Methods A finite element model with three dimensions Tile type C pelvic ring injury (central Denis III fracture sacrum) was produced. The were or 7 types models respectively as follows.(1)One S1 segment from right (C1); (2) One S2 (C2); (3)Two screws segments (C12); (4) one left...

10.3760/cma.j.issn.1001-8050.2017.10.008 article EN 2017-10-15

To analyze the effectiveness and safety of zoledronic acid combined with chemotherapy for lung cancer spinal metastases, 96 patients metastases were averagely classified into experimental group (gemcitabine, cisplatin, acid) control (gemcitabine cisplatin). An optimized noise variance estimation algorithm (OMAPB) was proposed based on maximum a posteriori Bayesian method (MAPB), applied to patient’s computed tomography (CT) scan. The results indicated that in terms curative effect, number...

10.1155/2022/6431852 article EN Computational and Mathematical Methods in Medicine 2022-05-06

Objective To compare the mechanical characteristics of lengthened and conventional sacroiliac screws for fixation unilateral vertical sacral fracture so as to provide evidences clinic practice.Methods A three-dimensional finite element model Tile type C pelvic injury (unilateral sacrum) was developed.Six different methods internal with were performed.Stability posterior ring during stance phase maximum stress on after measured compared.Results Mobilization one screw at S1 or S2...

10.3760/cma.j.issn.1001-8050.2014.07.026 article EN 2014-07-15

Objective To provide the anatomical basis for avoiding damage to superior gluteal artery in sacroiliac screw placement horizontally, by means of radiologic anatomy study on relationship between first sacral vertebral(S1) screws' entry points and pelvic outer branches. Methods Seventy-four CTA vascular images adults (37 women 37 men) were done with 128-slice spiral CT. The CT attendant measuring software was used portray thesafe bony entrance area(short forsafe area) S1 segment...

10.3760/cma.j.issn.2095-7041.2015.04.006 article EN Chin J Anat Clin 2015-08-06
Coming Soon ...