Yi Wang

ORCID: 0009-0003-0324-1969
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Non-Invasive Vital Sign Monitoring
  • ECG Monitoring and Analysis
  • Force Microscopy Techniques and Applications
  • Terahertz technology and applications
  • Healthcare Technology and Patient Monitoring
  • Magnetic Properties and Applications
  • Photonic Crystals and Applications
  • Advanced Surface Polishing Techniques
  • Laser Material Processing Techniques
  • Non-Destructive Testing Techniques
  • Nonlinear Optical Materials Studies
  • Neonatal Respiratory Health Research
  • Photonic and Optical Devices

Shanghai Jiao Tong University
2023-2024

International Peace Maternity & Child Health Hospital
2023-2024

Tsinghua University
2010-2023

An accurate micromagnetic model of the magnetic force microscope (MFM) tip has been developed to calculate effective dipole and its position in a simple point probe model, which are important quantitative explanation MFM images. The pyramid-shaped tips considered this paper; so cuboid cells body, as well triangular prism quadrangle pyramid at edge included accurately describe geometrical shape tip. field distribution analyzed, based on calculated domain structures with different materials...

10.1109/tmag.2010.2044510 article EN IEEE Transactions on Magnetics 2010-05-12

Refractive index sensing is attracting extensive attention in biochemical using terahertz technology. Various structures with strong confinements have been used to design sensors for improving the interaction between wave field and analytes, such as photonic crystals, nanowires, plasmonic structures, metamaterials. Terahertz based on two-dimensional crystal various areas ranging from disease diagnostics environmental pollution detection. For performance of sensor, a scheme high-density...

10.7498/aps.68.20191024 article EN Acta Physica Sinica 2019-01-01

Annually, a significant number of premature infants suffer from apnea, which can easily cause drop in oxygen saturation levels, leading to hypoxia. However, infant cardiopulmonary monitoring using conventional methods often necessitates skin contact, and they are not suitable for long-term monitoring. This article introduces non-contact technique an adjustable apnea detection algorithm. These developed custom-designed <italic xmlns:mml="http://www.w3.org/1998/Math/MathML"...

10.1109/tbme.2023.3325468 article EN IEEE Transactions on Biomedical Engineering 2023-10-18
Coming Soon ...