G. Naylor

ORCID: 0009-0009-0279-4506
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Magnetic confinement fusion research
  • Nuclear Physics and Applications
  • Laser-Plasma Interactions and Diagnostics
  • Superconducting Materials and Applications
  • Radiation Detection and Scintillator Technologies
  • Ionosphere and magnetosphere dynamics
  • Particle accelerators and beam dynamics
  • Fusion materials and technologies
  • Atomic and Subatomic Physics Research

Tokamak Energy (United Kingdom)
2023-2024

Abstract Ion temperatures of over 100 million degrees Kelvin (8.6 keV) have been produced in the ST40 compact high-field spherical tokamak (ST). excess 5 keV not previously reached any ST and only obtained much larger devices with substantially more plasma heating power. The corresponding fusion triple product is calculated to be <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>n</mml:mi> <mml:mi>i</mml:mi> <mml:mn>0</mml:mn>...

10.1088/1741-4326/acbec8 article EN cc-by Nuclear Fusion 2023-02-24

Abstract ST40 is a compact, high-field ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>B</mml:mi> <mml:mi mathvariant="normal">T</mml:mi> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> <mml:mtext>⩽</mml:mtext> <mml:mn>2.1</mml:mn> <mml:mstyle scriptlevel="0"/> <mml:mtext>T</mml:mtext> </mml:math> ) spherical tokamak (ST) with mission to expand the physics and technology basis for ST route commercial fusion. The research programme covers...

10.1088/1741-4326/ad6ba7 article EN cc-by Nuclear Fusion 2024-08-06

Following successful campaigns on the compact high field spherical tokamak ST40, resistive gold foil bolometers have now been installed to measure radiated power profile. Positioned midplane, two bolometer cameras offer perspectives of horizontal and vertical planes, while third camera, situated above provides a view top divertor plates, including X-point strike points. These use commercial off-the-shelf data acquisition platform with modules specifically designed for in Wheatstone bridge...

10.1063/5.0214400 article EN Review of Scientific Instruments 2024-08-01

This paper provides a comprehensive study of neutron calibration methodologies, specifically highlighting the capabilities for n–γ discrimination in diamond and EJ-309, stilbene scintillation detectors. The process detailed this includes pulse height analysis shape discrimination, relying on charge deposition resulting from both γ interactions. Utilizing 60Co 252Cf radiation sources, energy spectra these sources are obtained. characterized detectors were used ST40 experiments allowed...

10.1063/5.0218866 article EN Review of Scientific Instruments 2024-08-01

Abstract We present a new state-of-the-art Triple Wavelength Spectrometer (TriWaSp), recently deployed on ST40, high field low aspect ratio spherical tokamak. The TriWaSp has range of possible applications due to its flexible design; the current configuration focuses charge exchange recombination spectroscopy from carbon and neon impurities in ST40 plasma. This paper discusses detailed setup system presents initial ion temperature measurements using single line sight, which show good...

10.1088/1748-0221/18/03/c03023 article EN Journal of Instrumentation 2023-03-01

As part of its roadmap to developing commercial fusion plants, Tokamak Energy Ltd. operates the high field spherical tokamak ST40. Studies on this device will help expand physics basis by characterizing confinement and triple product. In support this, bolometers broadband x-ray sensitive diodes can provide information key energy loss mechanisms plasma. These include core magnetohydrodynamic activity that deteriorates confinement, such as sawtooth crashes be used characterize relaxations in...

10.1063/5.0218723 article EN Review of Scientific Instruments 2024-10-01
Coming Soon ...