- Microgrid Control and Optimization
- Optimal Power Flow Distribution
- Smart Grid Energy Management
- Electric Vehicles and Infrastructure
- Hybrid Renewable Energy Systems
- Energy and Environment Impacts
- Integrated Energy Systems Optimization
- Thermal Analysis in Power Transmission
- Power Systems and Renewable Energy
- Smart Grid and Power Systems
- Electric Power System Optimization
- Advanced Battery Technologies Research
- Energy Load and Power Forecasting
- Electromagnetic Compatibility and Noise Suppression
- Lightning and Electromagnetic Phenomena
- Power System Optimization and Stability
- Real-time simulation and control systems
- Renewable energy and sustainable power systems
Technical University of Denmark
2021-2023
Indian Institute of Science Bangalore
2018
Utility-scale and small scale wind solar power installations along with electric vehicle charging stations, other active sources of energy are increasing at the medium lower voltage levels in distribution grid. This situation requires a better understanding impact high penetration weather-dependent renewable on operating conditions network both low levels. Despite need, multi-voltage level model, based real data generation data, has not been presented for grid studies. paper presents...
Converter-connected renewable energy sources (RES) in the distribution network alter power flow network. Often, grid reinforcements and additional local reactive are needed to maintain steady state operation. RES is an accessible source for system operators optimize operations. However, non-linearity non-convexity converter equations make their modelling challenging, which further results under-utilization of capability from these sources. Oftentimes, converter-connected generator partially...
Download This Paper Open PDF in Browser Add to My Library Share: Permalink Using these links will ensure access this page indefinitely Copy URL DOI
Accurately fitting rational functions to the frequency response of characteristic impedance and admittance is very crucial for dependent modeling transmission lines. Vector a most popular method line. An R-C equivalent circuit will then be obtained from simulate line using Marti's model. intuitive single step proposed in this paper directly fit an impedance. A close enough achieved with lesser number poles & zeros method. This found reduce simulation time drastically by 89.84%.
The increased penetration of weather-dependent distributed generation, such as wind power plants and photovoltaics, in distribution networks, presents new challenges for the system operators to improve their networks' operation by effectively utilizing available resources. A higher amount generation also directly translates more losses network. In this regard, plant capabilities can prove valuable avoid network congestion, maintain supply reduce losses. This paper aims minimize networks...
Network operators have been increasingly concerned with procuring reactive power sources as more synchronous generators are planned to be decommissioned and number of distributed generation is on the rise. Reactive necessary in evolving grid support additional flow avoid expensive reinforcements. Converter connected renewable can a solution both provide much needed distribution grids voltage regulation transmission network via altering feed-in. This research explores capabilities...
<div>The increased penetration of wind power plants (WPPs) in distribution networks challenges the system operators (DSOs) to improve and optimize networks’ operation. A higher amount local production translates more losses network. This paper proposes a deterministic optimization methodology minimize with WPPs, by exploiting WPPs’ capability control reactive coordination on-load tap changers from MV/HV transformer, avoiding need for network reinforcements. The principal objective is...
Future distribution grids are likely to shift away from a passive grid consuming power an active with high share of weather-dependent renewable generation. Distribution operations greatly interlinked between different voltage levels and depend upon the fluctuating load demand. Thus it is imperative study analyze multi-voltage level understand challenges opportunities in In this research, open-source model, named DTU 7k-Bus Active Grid Model, presented. The model spans across three modeled on...
Converter-connected renewable energy sources (RES) in the distribution network alter power flow network. Often, grid reinforcements and additional local reactive are needed to maintain steady state operation. RES an accessible source for system operators optimize operations. However, non-linearity non-convexity converter equations make their modelling very challenging, which further results under-utilization of capability from these sources. This paper presents approach incorporate a convex...
<div>Utility-scale and small scale wind solar power installations along with electric vehicle charging stations, other active sources of energy are increasing at the medium lower voltage levels in distribution grid. This situation required a better understanding impact high penetration weather-dependent renewable on operating conditions network both low levels. Despite need, multi-voltage level model, based real data generation data, has not been presented for grid studies. paper...
An emerging approach for effective grid integration of renewable energy sources (RES) involves hybridizing one or two types RES with battery storage (BES). A BES in such a hybrid power plant (HPP) allows maximizing generation and profitability while offering ancillary services to the grid. Various operators around world are also exploring stand-alone goal avoiding reinforcements boosting capacity existing network assets as transmission lines. However, it is unclear if an HPP has leverage...
Distribution networks worldwide are on the verge of a significant transformation owing to increasing share distributed generation connected, especially wind and solar, at medium low voltage levels. The traditional distribution network infrastructure, designed for uni-directional power flow, is non-optimal accommodate sources, leading bi-directional flow. Hydrogen systems, along with PV plant, or battery storage, have been investigated optimal day-ahead operation, regulation, active reactive...
<div>Utility-scale and small scale wind solar power installations along with electric vehicle charging stations, other active sources of energy are increasing at the medium lower voltage levels in distribution grid. This situation required a better understanding impact high penetration weather-dependent renewable on operating conditions network both low levels. Despite need, multi-voltage level model, based real data generation data, has not been presented for grid studies. paper...
<div>The increased penetration of wind power plants (WPPs) in distribution networks challenges the system operators (DSOs) to improve and optimize networks’ operation. A higher amount local production translates more losses network. This paper proposes a deterministic optimization methodology minimize with WPPs, by exploiting WPPs’ capability control reactive coordination on-load tap changers from MV/HV transformer, avoiding need for network reinforcements. The principal objective is...