Marie-Noëlle Amiot

ORCID: 0000-0002-5409-1572
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Radioactive Decay and Measurement Techniques
  • Radioactivity and Radon Measurements
  • Scientific Measurement and Uncertainty Evaluation
  • Radiation Detection and Scintillator Technologies
  • Nuclear Physics and Applications
  • Radiation Therapy and Dosimetry
  • Radiation Effects and Dosimetry
  • Neutrino Physics Research
  • X-ray Spectroscopy and Fluorescence Analysis
  • Particle Detector Development and Performance
  • Radiation Dose and Imaging
  • Advanced Radiotherapy Techniques

CEA LIST
2010-2022

Commissariat à l'Énergie Atomique et aux Énergies Alternatives
2003-2022

CEA Paris-Saclay
2006-2022

Laboratoire de Mesure du Carbone 14
2022

Laboratoire National Henri Becquerel
2003-2019

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements mono-radionuclide sources were performed over periods from 200 days up four decades 14 laboratories across globe. Residuals exponential nuclear curves inspected for annual oscillations. Systematic deviations a purely curve differ one data set another are attributable instabilities in instrumentation measurement conditions. most stable...

10.1016/j.physletb.2016.08.038 article EN cc-by Physics Letters B 2016-08-29

Pressurized re-entrant (or 4π) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields metrology nuclear medicine. As a secondary method, these instruments need be calibrated with appropriate standards from primary or direct standardization. The use over 50 years has been well described numerous publications, such as Monographie BIPM-4 special issue Metrologia on radionuclide...

10.1088/0026-1394/52/3/s108 article EN Metrologia 2015-05-22

10.1016/j.nima.2012.05.025 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2012-05-12

When new materials appear as potential alternatives for radiation detection, several criteria have to be fulfilled.

10.1039/c7cp04034b article EN Physical Chemistry Chemical Physics 2017-01-01

10.1016/j.apradiso.2004.06.002 article EN Applied Radiation and Isotopes 2004-08-05

Abstract In vivo dosimetry for patient radioprotection is a real challenge concerning new radiotherapy treatments. this study we aim to develop dosimeter based on tissue equivalent material, flexible and adaptable the morphology in order perform complex irradiation beams. Here, report evaluation standard beams of highly composed silicone elastomer containing leucomalachite green as radiochromic dye give first estimation LMG-micelle hydrogel response. All results are compared commercially...

10.1088/1742-6596/2167/1/012002 article EN Journal of Physics Conference Series 2022-01-01

In the context of high-energy physics experiments, particle accelerators create a significant dose radiations, up to 10 6 Gy for example at Large Hadron Collider (LHC, Cern).Control detectors, such as scintillators, are affected by these high irradiation levels.The literature mentions that light yield organic scintillators dramatically drops when strongly irradiated.However, tested can recover some their output with time.To best our knowledge, only luminescent properties plastic were...

10.1051/epjconf/201817001011 article EN cc-by EPJ Web of Conferences 2018-01-01
Coming Soon ...