Research Areas
  • Advanced Chemical Sensor Technologies
  • Analytical Chemistry and Sensors
  • Biosensors and Analytical Detection
  • Electrochemical sensors and biosensors
  • Electrochemical Analysis and Applications
  • Water Quality Monitoring and Analysis
  • Analytical chemistry methods development
  • Spectroscopy and Chemometric Analyses
  • Water Quality Monitoring Technologies
  • Advanced biosensing and bioanalysis techniques
  • Gas Sensing Nanomaterials and Sensors
  • Mass Spectrometry Techniques and Applications
  • Electrical and Thermal Properties of Materials
  • Pesticide Residue Analysis and Safety
  • Dye analysis and toxicity
  • Various Chemistry Research Topics
  • Polyamine Metabolism and Applications
  • Analytical Chemistry and Chromatography
  • Identification and Quantification in Food
  • Carbon and Quantum Dots Applications
  • Molecular Sensors and Ion Detection
  • Healthcare during COVID-19 Pandemic
  • Biochemical Analysis and Sensing Techniques
  • Advanced oxidation water treatment
  • Environmental Chemistry and Analysis

Universidade Federal de Pernambuco
2019-2025

Clemson University
2024-2025

Institute for Analytical Instrumentation
2025

Universidade Federal do Pará
2016-2020

Universidade de São Paulo
2014-2018

Universidade Federal de São Carlos
2010-2015

Departamento de Ciência e Tecnologia
2011-2015

Instituto Butantan
2015

Universidade Federal da Paraíba
2007-2011

University of Beira Interior
2010

The digital image analysis together with spot-test based on a colorimetric assay produces fast, low waste, screening and<italic>in situ</italic>analysis.

10.1039/c5ay00529a article EN Analytical Methods 2015-01-01

Abstract A bismuth‐film electrode (BiFE) ex situ electrochemically deposited onto a copper substrate has been presented for paraquat determination. The bismuth film was at an applied potential of −0.18 V vs. Ag/AgCl (3.0 M KCl) 200 s. analytical curve linear in the concentration range from 6.6×10 −7 to 4.8×10 −5 with limit detection 9.3×10 −8 M. method satisfactory results confidence level 95% and performance evaluated water samples.

10.1002/elan.200900553 article EN Electroanalysis 2010-03-30

A combination of a spot-test and digital image analysis for determination sulfite in beverages by reduction Fe(<sc>iii</sc>) complex.

10.1039/c5ay01372k article EN Analytical Methods 2015-01-01

This paper reports the development and application of a low-cost multifunctional webcam spectrophotometer for conduct molecular absorption fluorometric measurements. The equipment, which costs approximately US$20 to be fabricated, consists webcam, diffraction grating, slit, all positioned inside an MDF box. Spectral measurements were carried out using equipment with aid free software. was found suitable conducting qualitative quantitative analyses fluorescence, absorption, emission spectra...

10.1021/acs.jchemed.0c01085 article EN Journal of Chemical Education 2021-02-04

A simple chromatographic paper based colorimetric assay for the analysis of selected food compounds.

10.1039/c5ay01556a article EN Analytical Methods 2015-01-01

A simple, low-cost and easy-to-handle procedure based on carbon quantum dots is proposed to check commercially available formulated microbicides that are used mitigate the transmission of viruses, such as SARS-COV-2, or bacterial diseases.

10.1039/d2ay00678b article EN Analytical Methods 2022-01-01

The present study reports, for the first time, development and application of a method based on digital imaging analysis simultaneous determination Cu 2+ furfural in cachaça samples using two-phase system chemometrics tools.

10.1039/d3ay00311f article EN Analytical Methods 2023-01-01
Coming Soon ...