Carmine Landi

ORCID: 0000-0003-0922-883X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced Electrical Measurement Techniques
  • Power Quality and Harmonics
  • Sensor Technology and Measurement Systems
  • Magnetic Properties and Applications
  • Power Line Communications and Noise
  • Electromagnetic Compatibility and Noise Suppression
  • Railway Systems and Energy Efficiency
  • Non-Destructive Testing Techniques
  • Electrical Contact Performance and Analysis
  • Network Time Synchronization Technologies
  • Advancements in PLL and VCO Technologies
  • Power Transformer Diagnostics and Insulation
  • Electrostatic Discharge in Electronics
  • Advanced Battery Technologies Research
  • Smart Grid Energy Management
  • Analog and Mixed-Signal Circuit Design
  • Energy Efficient Wireless Sensor Networks
  • Microbial Metabolic Engineering and Bioproduction
  • Magnetic Field Sensors Techniques
  • Fault Detection and Control Systems
  • Smart Grid Security and Resilience
  • Power Systems Fault Detection
  • Fungal and yeast genetics research
  • Power System Optimization and Stability
  • Advanced MEMS and NEMS Technologies

University of Campania "Luigi Vanvitelli"
2016-2025

Costruzioni Apparecchiature Elettroniche Nucleari (Italy)
2024

Ricerca sul Sistema Energetico (Italy)
2024

Istituto Nazionale di Ricerca Metrologica
2024

Azienda Ospedaliera Universitaria Università degli Studi della Campania Luigi Vanvitelli
2018-2023

University of Salerno
2010-2023

Polytechnic University of Turin
2020

University of Naples Federico II
2008-2013

Informa (Italy)
2010

Università degli studi di Cassino e del Lazio Meridionale
2010

This paper aims at characterizing and improving the metrological performances of current voltage instrument transformers (CTs VTs) in harmonic measurements power system. A theoretical analysis is carried out to demonstrate that, due iron core nonlinearity, CT VT output signal distorted even when input a pure sine wave. Starting from this analysis, new method for characterization compensation proposed. In first step, they are characterized sinusoidal conditions phasors measured; second these...

10.1109/tim.2018.2880060 article EN IEEE Transactions on Instrumentation and Measurement 2018-12-13

Nowadays, the interest in low-cost and increasingly accurate phasor measurement units (PMUs) for active distribution systems is steadily growing. In this paper, an algorithm synchrophasor, fundamental frequency, rate of change frequency estimation tailored processing platforms with limited computational resources described characterized extensively terms both accuracy time. The proposed solution harnesses main advantages two state-of-the-art algorithms, i.e., interpolated discrete Fourier...

10.1109/tim.2017.2775458 article EN IEEE Transactions on Instrumentation and Measurement 2018-01-19

The assessment of the power quality (PQ) could be a valuable tool to foster efficiency railway systems. PQ is well-addressed topic in conventional ac 50/60 Hz systems, and many procedures, algorithms measurement systems were presented international standards widely discussed scientific literature. A less explored research field traction supply particular with reference dc 16.7 article explores this theme, proposing an extension definitions standard procedures for some main indexes, well...

10.1109/tim.2020.2967162 article EN cc-by IEEE Transactions on Instrumentation and Measurement 2020-01-17

A setup for the measurement of frequency response voltage transformers under actual waveform conditions is presented. It based on a two-step procedure that makes use high gas insulated capacitors and digital bridge. allows calibrations using distorted waveforms, with fundamental tone at medium level superimposed harmonics up to 20% 15 kHz. Combined standard uncertainty in transformer (VT) error estimated 200 μV/V ratio 300 μrad phase displacement 10 First applications VTs different rated...

10.1109/tim.2017.2652638 article EN IEEE Transactions on Instrumentation and Measurement 2017-02-07

The advance in power electronics causes, over the years, an increasing diffusion of nonlinear loads. Moreover, electrical generation systems are going to include a growing amount solar and wind energy, characterized by time-variant flow energy and, very often, with relevant distortion. These aspects give more emphasis monitoring conducted disturbances on wide frequency range, consequently, voltage current transducers adopted for this aim must have proper bandwidth. Voltage transformers (VTs)...

10.1109/tim.2010.2044616 article EN IEEE Transactions on Instrumentation and Measurement 2010-03-26

Microbial population dynamics in bioreactors depend on both nutrients availability and changes the growth environment. Research is still ongoing optimization of bioreactor yields focusing increase maximum achievable cell density.A new process-based model proposed to describe aerobic Saccharomyces cerevisiae cultured glucose as carbon energy source. The considers main metabolic routes assimilation (fermentation ethanol respiration) occurrence inhibition due accumulation other self-produced...

10.1186/s12934-015-0295-4 article EN cc-by Microbial Cell Factories 2015-07-29

The electrical arc occurring in the sliding contact between supply line and current collector (pantograph) of an locomotive is a fast transient phenomenon able to degrade progressively line-to-pantograph quality and, consequently, continuity operation. In order increase energy efficiency railway system, inexpensive solution constituted by detection event analysis voltage measurements already available on-board train. An essential activity reach this objective set up reliable model system...

10.1109/tim.2019.2902805 article EN IEEE Transactions on Instrumentation and Measurement 2019-04-16

The integration of renewable energy sources on a large scale in the electrical distribution systems, as well widespread non-linear loads, has led to significant increase power quality (PQ) disturbances. For this reason, PQ monitoring is also becoming key task medium voltage (MV) grids. measurement at MV levels can only be performed using instrument transformers (ITs) down level and current suitable for input stage instruments. However, no international standards currently require...

10.3390/s22155847 article EN cc-by Sensors 2022-08-04

Extracellular DNA (exDNA) can be actively released by living cells and different putative functions have been attributed to it. Further, homologous exDNA has reported exert species-specific inhibitory effects on several organisms. Here, we demonstrate experimental evidence, including 1H-NMR metabolomic fingerprint, that the growth rate decline in Saccharomyces cerevisiae fed-batch cultures is determined accumulation of medium. Sequencing such secreted represents a portion entire genome,...

10.15698/mic2023.12.810 article EN cc-by Microbial Cell 2023-11-23

Today there is a wide application of different electronic apparatus that both produce electromagnetic disturbances on the supply power system and are sensitive to them. Power present typical electric utility distribution systems degrade product quality, increase process downtime, dissatisfy commercial customers. For these reasons, monitoring quality networks has become an issue international interest. To monitor in this paper, we propose digital measurement station. Its main features remote...

10.1109/tim.2003.809080 article EN IEEE Transactions on Instrumentation and Measurement 2003-02-01

In this paper, the authors propose a methodology to guide verification of single-phase energy meters under sinusoidal and nonsinusoidal conditions. At first, brief review is presented about definitions quantities that should be measured or monitored for revenue purposes their relationship with electrical are recognized important in terms metering accuracy. Then, design an experiment allows testing combination disturbances showing positive negative correlations described. Finally, hardware...

10.1109/tim.2007.903607 article EN IEEE Transactions on Instrumentation and Measurement 2007-09-17

Calibration of electrical energy meters is coming up as a metrological concern. The latest European Union (EU) directives about measuring instruments adopted for commercial transactions state that their accuracy has to be verified in actual operating conditions. This requirement leaving all laboratories involved meter calibration serious difficulty because this kind verification is, at the moment, still not fully developed or even clarified aspects. In paper, measurement equipment presented....

10.1109/tim.2008.2005079 article EN IEEE Transactions on Instrumentation and Measurement 2008-10-07

In this paper, the design and prototype implementation of a power-quality (PQ) measuring monitoring instrument based on an embedded controller with reconfigurable I/O are described. The performs calculation main PQ indexes according to latest standards, it can be reconfigured for future standard developments. It is properly implemented operate in stand-alone mode, interfaced hardware modules exchange information data, locally, RS-232 connection or, remotely, Transmission Control...

10.1109/tim.2009.2016890 article EN IEEE Transactions on Instrumentation and Measurement 2009-07-01

This paper analyzes the accuracy of algorithms commonly adopted in instruments devoted to detection and characterization voltage dips (which are also called sags). analysis is particularly interesting, because results dip measurements utilized for calculation severity levels site indexes, which important parameters not only assessment quality level power supply but selection equipment with proper intrinsic immunity. Instruments measurement still have unresolved technical theoretical issues...

10.1109/tim.2010.2045256 article EN IEEE Transactions on Instrumentation and Measurement 2010-04-09

This paper reports the results of analyses on accuracy algorithms commonly adopted in instruments devoted to detection and characterization voltage dips (also called sags). analysis is particularly interesting because dip measurements are used for calculation severity levels site indexes that important parameters assessment quality level power supply but also selecting equipment with proper intrinsic immunity. Anyway, measurement still have unresolved technical theoretical issues related...

10.1109/tim.2013.2278996 article EN IEEE Transactions on Instrumentation and Measurement 2013-09-25

With the advent of smart grid paradigm, medium voltage (MV) distribution networks have experienced great structural changes that, with massive deployment distributed generation, impose network monitoring in a wider frequency range, up to some kilohertz, evaluate power quality (PQ) phenomena and ensure proper operation. Classical instrument transformers (VT) primary rated voltages higher than few tens kilovolt are typically usable limited range around frequency, thus for accurate measurements...

10.1109/jsen.2017.2726116 article EN IEEE Sensors Journal 2017-07-12

Instrument Transformers (ITs) are essential devices for all the measurement tasks, f.i. metering, protection and diagnostics, in electricity grids, since they scale voltage current down to levels compatible with measuring instruments. At input of Power Quality (PQ) instruments Phasor Measurement Units (PMUs), inductive transformers (VTs CTs) still most used ITs, even if, their performance presence disturbances is not fully assessed. This paper analyses impact CTs on fundamental...

10.1016/j.measurement.2020.107535 article EN cc-by-nc-nd Measurement 2020-01-24

This paper presents a digital instrument for the power quality analysis in systems where voltage or current waveforms are non-sinusoidal. It is based on C40 DSP and special high-speed data acquisition system. The performed by recursive algorithm which allows mutable system properties to be tracked. also goes discuss performance of an prototype, both terms accuracy specifications speed measurement.

10.1109/imtc.1996.507304 article EN 2002-12-23

The smart grid approach is envisioned to take advantage of all available modern technologies in transforming the current power system provide benefits stakeholders fields efficient energy utilisation and wide integration renewable sources. Energy storage systems could help solve some issues that stem from usage terms stabilizing intermittent production, quality peak mitigation. With into grids, their accurate modeling becomes a necessity, order gain robust real-time control on network,...

10.3390/en6094572 article EN cc-by Energies 2013-09-03

This paper presents a real-time compensation method for the improvement of frequency behavior measurement transducers already operating or to be installed in transmission and distribution grids. The developed technique relies on identification an infinite impulse response digital filter with complex equal inverse transducer, whose parameters are evaluated through hybrid scheme based combination stochastic deterministic procedure. Attention is focused algorithm capability, sensitivity...

10.1109/tim.2015.2398971 article EN IEEE Transactions on Instrumentation and Measurement 2015-04-17

Smarter sensors and transducers are required in the new smart grid scenario with increased performances, terms of high accuracy wide frequency bandwidth. Traditional calibration systems, developed for conventional instrument transformers not suitable performance verification types non-conventional transformers, both input range Therefore, a industrial comparator sensor is presented this paper, which intended voltage current from dc to tens kilohertz. Its performances allow calibration,...

10.1109/jsen.2017.2724299 article EN IEEE Sensors Journal 2017-07-07

Similar to low-voltage power systems, also in medium voltage networks there is a growing need for quality (PQ) analyses, required by the increasing diffusion of distributed generation sources equipped with switching converters. This leads employment transducers and measurement techniques able convert acquire signals better accuracy on wider frequency range than conventional current instrument transformers. Voltage dividers (VDs) are expected become most used PQ assessments, since, respect...

10.1109/tim.2014.2317294 article EN IEEE Transactions on Instrumentation and Measurement 2014-05-13

In PV applications, under mismatching conditions, it is necessary to adopt a maximum power point tracking (MPPT) technique which able regulate not only the voltages of modules array but also DC input voltage inverter. Such can be considered hybrid MPPT (HMPPT) since neither distributed on or centralized at this paper new HMPPT presented and discussed. Its main advantages are high efficiency speed obtained by means fast estimate optimal values inverter voltage. The compared with simple...

10.1155/2014/125918 article EN cc-by Advances in Power Electronics 2014-06-03
Coming Soon ...