Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden
2019-2023
Introduction. The matter of the replacement acetabular defects is becoming increasingly relevant today. In their clinic authors used custom-made implants with trabecular coating for in acetabulum where and when it was necessary to ensure extended fixation component. Purpose — evaluate short-term clinical functional outcomes, osteointegration porous coated implants, overall survival structural components identify causes failures complications. Materials Methods. During study interviewed...
Options for treatment of massive acetabular defects are very diverse and continue to be a challenge the surgeon. Although custom implants do not perform well over other reconstruction methods, design variability offers wide option reliable primary fixation. There were performed 115 reconstructions with in Russian Scientific Research Institute Traumatology Orthopedics named after R.R. Vreden Ministry Health Federation from 2015 2019 years. The aim our study was clarify define main types which...
Background. Arthroscopic methods of diagnosis and treatment elbow diseases have not yet become widespread due to the small volume joint, close location neurovascular bundles manipulation difficulty.
 The aim study was determine safe zones for minimally invasive approaches in patients with lateral medial epicondylitis.
 Methods. A complex anatomical clinical performed. part carried out on 30 non-fixed preparations upper limb. features tendon-muscular structures surrounding were...
Background. There is not enough research on the topic of arthroscopic treatment medial epicondylitis. Topographic studies are needed to justify surgical approaches with minimal trauma collateral ligament and ulnar nerve. The aim study was optimize epicondylitis evaluate its clinical effectiveness based results topographic anatomical study. Materials Methods. material for 12 «fresh» preparations human elbow joint, which 6 were taken from female cadavers, — men. features structure topography...
To evaluate diagnostic value of routine preoperative laboratory tests such as erythrocyte sedimentation rate (ESR), serum C-reactive protein (CRP) and microbiological examination joint aspirate in patients with periprosthetic infection or its recurrence scheduled for revision hip arthroplasty.There were 117 patients. Preoperative CRP ESR, the culture pre- intraoperative aspirates tissue biopsies studied. We analyzed significance these parameters likelihood depending on increase CRP/ESR...
РЕВИЗИОННОЕ ЭНДОПРОТЕЗИРОВАНИЕ ПРИ ДЕФЕКТАХ ДНА ВЕРТЛУЖНОЙ ВПАДИНЫ НА ФОНЕ УНИПОЛЯРНОГО ЭНДОПРОТЕЗИРОВАНИЯ У ПАЦИЕНТОВ СТАРЧЕСКОГО ВОЗРАСТА МидаевА.И. 1 ,Менькин З.Д. ,Джавадов А.А. ,АмбросенковА.В. ,Близнюков В.В. , Бояров Демин А.С. ,Ражетдинов Т.И. Шахмарданов Ш
Background One of the most common reasons patients’ visits with complaints in area elbow joint is epicondylitis joint. Surgical treatment recommended if conservative fails after 6-12 months. Arthroscopy one current surgical methods minimally invasive interventions on Purpose To conduct a comparative assessment effectiveness treating using modified arthroscopic and open techniques Methods A prospective cohort-controlled study was performed 120 patients. The patients were divided into two...
Background. Glove damage during orthopedic operation can reach an incidence of 26.1%, whereas perforations in gloves go unnoticed by surgical team members most cases (up to 82%), which certainly increases the risk wound contamination and hemocontact infection transmission. Aim. The aim this study was assess frequency glove among hip arthroplasty members, identify nature, location, factors gloves. Materials methods. A total 1418 (709 pairs) that were used surgeons, assistants, nurses 154...