H. Bourdon

ORCID: 0000-0003-2733-8266
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Intraocular Surgery and Lenses
  • Glaucoma and retinal disorders
  • Retinal and Optic Conditions
  • Ophthalmology and Visual Health Research
  • Corneal surgery and disorders
  • Optical Coherence Tomography Applications
  • Ophthalmology and Visual Impairment Studies
  • Traumatic Ocular and Foreign Body Injuries
  • Photoacoustic and Ultrasonic Imaging
  • Cardiac, Anesthesia and Surgical Outcomes
  • Thermography and Photoacoustic Techniques
  • Metabolism and Genetic Disorders
  • Retinal Imaging and Analysis
  • Vascular Malformations Diagnosis and Treatment
  • Botulinum Toxin and Related Neurological Disorders
  • Anesthesia and Pain Management
  • Plant Toxicity and Pharmacological Properties
  • Neonatal Health and Biochemistry
  • Cerebral Venous Sinus Thrombosis
  • Retinal and Macular Surgery
  • Ocular Surface and Contact Lens
  • Prenatal Substance Exposure Effects
  • Retinal Diseases and Treatments
  • Poisoning and overdose treatments
  • Botanical Research and Chemistry

Centre hospitalier national d'ophtalmologie des Quinze-Vingts
2020-2022

Université Paris Cité
2016-2022

Institut Langevin
2022

Centre Hospitalier de Versailles
2019

Hôpital Ambroise-Paré
2019

Laboratoire de PhysioMédecine Moléculaire
2012

Hôpital Salvator
1996

10.1016/j.jfo.2020.05.023 article FR Journal Français d Ophtalmologie 2020-12-16

Objective To assess linear correlation between swept-source optical coherence tomography (SS-OCT) lens density variation and patients’ best-corrected visual acuity (BCVA). Methods analysis Linear densitometry was performed on horizontal images from 518 eyes, obtained using SS-OCT. All densities the anterior to posterior side of cataract were exported for detailed analysis. The algorithm used a classical random forest regression machine learning approach with fourfold cross-validation,...

10.1136/bmjophth-2021-000730 article EN cc-by-nc BMJ Open Ophthalmology 2021-05-01

We propose to record "en face" Full Field OCT interferometric images of paintings on canvas using a cooled MCT camera working in the range 3-5.5 micrometers coupled glowbar broadband source that allows reach shot noise limited detection. Penetration various paints is spectacular at these large wavelengths: we measure mean free path 5 10 times larger than visible/near IR wavelengths. find easily observed under paint. This result, obtained without averaging, paves way non-contact,...

10.1117/12.2606201 article EN 2022-03-04
Coming Soon ...