Chang‐Wei Huang

ORCID: 0000-0003-3210-5483
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Ultrasound and Hyperthermia Applications
  • Photoacoustic and Ultrasonic Imaging
  • High Entropy Alloys Studies
  • Topology Optimization in Engineering
  • High-Temperature Coating Behaviors
  • Additive Manufacturing Materials and Processes
  • Glass properties and applications
  • Advanced ceramic materials synthesis
  • Structural Health Monitoring Techniques
  • Seismic Performance and Analysis
  • Metal and Thin Film Mechanics
  • Composite Structure Analysis and Optimization
  • Structural Engineering and Vibration Analysis
  • Bone Tissue Engineering Materials
  • Ultrasound and Cavitation Phenomena
  • Ultrasound Imaging and Elastography
  • Advanced Multi-Objective Optimization Algorithms
  • Infrastructure Maintenance and Monitoring
  • Ultrasonics and Acoustic Wave Propagation
  • Dental Implant Techniques and Outcomes
  • Aluminum Alloys Composites Properties
  • Advanced materials and composites
  • Structural Behavior of Reinforced Concrete
  • Infrared Thermography in Medicine
  • Geotechnical Engineering and Underground Structures

Northeast Forestry University
2025

Chung Yuan Christian University
2015-2024

United Microelectronics (Taiwan)
2019

National Changhua University of Education
2016

National Taiwan University
2000-2015

National University of Tainan
2010

St. John's University
2006

Chang Gung University
2005

The CoCrFeMnNi high entropy alloys remain an active field over a decade owing to its excellent mechanical properties. However, the application of is limited because relatively low tensile strength. Here we proposed micromechanical model which adopted from theory dislocation density investigate strengthening mechanisms precipitation chromium-rich non-equiatomic alloy. microstructures were obtained directly SEM-BSE images with different annealing temperatures. framework validated by comparing...

10.1038/s41598-023-30508-z article EN cc-by Scientific Reports 2023-02-28

A strut-and-tie design methodology is presented for three-dimensional reinforced concrete structures. The unknown model realized through the machinery of a refined evolutionary structural optimization method. Stiffness struts and ties computed from an evolved topology finite element to solve statically indeterminate problems. In addition, compressive strength nodal zones evaluated using Ottosen's four-parameter criterion. Numerical examples are studied demonstrate that proposed suitable...

10.1061/(asce)0733-9445(2006)132:6(929) article EN Journal of Structural Engineering 2006-05-16

The application of hydrogels in flexible sensing has received increasing attention, but the simultaneous preparation with good structural stability, strain sensitivity, freezing resistance, and drying resistance remains a challenge. Based on this, GG-nanocellulose/sodium alginate/polyacrylamide composite hydrogel hierarchical network structure was constructed by one-step synthesis incorporating graphene oxide (GO) glycerol into hydrogel. remained structurally intact after 100 compression...

10.3390/gels11060379 article EN cc-by Gels 2025-05-22

Abstract A simple image‐based method for measuring plane strain fields on the surface of specimens in earthquake engineering experiments was developed. This integrated camera calibration, stereo triangulation, image metric rectification and template matching techniques to develop a that cost‐effective, easy apply provided satisfactory level measurement accuracy. zero‐strain test conducted using this showed accuracy achieved 0.04 pixels. That is, relative displacement 0.005 mm 0.001....

10.1002/eqe.1111 article EN Earthquake Engineering & Structural Dynamics 2011-03-22

An integrated computational framework was developed in this study for modeling high-intensity focused ultrasound (HIFU) thermal ablation. The temperature field obtained by solving the bioheat transfer equation (BHTE) through finite element method; while, lesion considered as a denatured material experiencing phase transformation and modeled with latent heat. equivalent attenuation coefficient, which considers temperature-dependent properties of target diffraction due to bubbles, proposed...

10.1016/j.ultsonch.2015.06.003 article EN cc-by-nc-nd Ultrasonics Sonochemistry 2015-06-17

A three‐dimensional finite element model describing the thermal–mechanical stress distribution in multilayer ceramic capacitors ( MLCC s) during termination firing, soldering, and bending tests is presented. Numerical results indicate that thermal residual stresses originating from soldering process are approximately one‐fifth to half of magnitude flexural at crack occurrence board flex test. The peak tensile numerical simulations correlates with initiation site observed situ tests. effects...

10.1111/ijac.12176 article EN International Journal of Applied Ceramic Technology 2013-09-12

Polymer-mediated lock-and-key assembly via depletion attraction is purely a shape-recognition process without any molecular bonding. Since the relates to osmotic pressure and excluded volume, binding tendency in dispersion of colloids can be controlled by adjusting characteristics polymeric depletants. In this work, dissipative particle dynamics accounting for explicit solvents, polymers, multiple lock-key pairs are performed investigate influences polymer concentration, chain length,...

10.1021/acs.langmuir.5b02527 article EN Langmuir 2015-11-13

A novel lightweight Al-Ti-Cr-Mn-V medium-entropy alloy (MEA) system was developed using a nonequiatiomic approach and alloys were produced through arc melting drop casting. These comprised body-centered cubic (BCC) face-centered (FCC) dual phase with density of approximately 4.5 g/cm3. However, the fraction BCC morphology FCC can be controlled by incorporating other elements. The results compression tests indicated that these exhibited prominent strength (~1940 MPa) ductility (~30%)....

10.3390/e22010074 article EN cc-by Entropy 2020-01-06

The effects of an implant on temperature distribution in a tissue-mimicking hydrogel phantom during the application therapeutic ultrasound were investigated. In vitro experiments conducted to compare influences plastic and metal implants diathermy calibrate parameters finite element simulation models. histories characteristics opaque (denatured) areas phantoms predicted by numerical simulations show good correlation with those observed experiments. This study provides insight into profile...

10.1016/j.ultsonch.2016.02.019 article EN cc-by-nc-nd Ultrasonics Sonochemistry 2016-02-14

This paper presents a structural reanalysis method and its applications in optimal design of trusses. technique is derived primarily on the basis reduced formulation, it has several advantages over previous methods. In particular, system uncoupled by using Gram–Schmidt orthonormalization procedure an error measure introduced to adaptively monitor whether good approximate solution achieved. The latter aspect makes this suitable for use problems because changes variables usually vary during...

10.1002/1097-0207(20001120)49:8<1007::aid-nme988>3.0.co;2-p article EN International Journal for Numerical Methods in Engineering 2000-01-01
Coming Soon ...