- COVID-19 Clinical Research Studies
- Long-Term Effects of COVID-19
- Muscle activation and electromyography studies
- COVID-19 diagnosis using AI
- COVID-19 and healthcare impacts
- SARS-CoV-2 and COVID-19 Research
- Phonocardiography and Auscultation Techniques
- Ergonomics and Musculoskeletal Disorders
- Sepsis Diagnosis and Treatment
- Healthcare Regulation
- Telemedicine and Telehealth Implementation
- Motor Control and Adaptation
- Respiratory Support and Mechanisms
- Quality and Safety in Healthcare
Universidade Federal de Uberlândia
2021-2023
COVID-19 is a disease caused by SARS-CoV-2 (coronavirus type 2 of the severe acute respiratory syndrome), isolated in China, December 2019. The strategy currently used physicians to control and treat symptoms, including non-pharmacological treatments, as there still no specific treatment for COVID-19. Thus, aim this article carry out systematic review about treatments COVID-19, addressing current status consensus found literature. Three databases were consulted evidence referring drugs...
During the aging process, cognitive functions and performance of muscular neural system show signs decline, thus making elderly more susceptible to disease death. These alterations, which occur with advanced age, affect functional in both lower upper members, consequently human motor functions. Objective measurements are important tools help understand characterize dysfunctions limitations that due neuromuscular changes related advancing age. Therefore, objective this study is attest...
COVID-19 has spread and continues to rapidly across the world. There is still no approved effective treatment for disease. Several drugs are being administered empirically patients, based on results from studies with limited methodologies. an urgent need systematic reviews support decision makers development of guidelines. The purpose this paper was conduct a review drug carried out worldwide COVID-19, verifying effectiveness methodological quality. search relevant articles performed in...
Abstract This paper aims at validating the conformity of linear peristaltic volumetric infusion pump (LPVIP) using as reference a flow analyzer, model IN-300. The IN-300 has an operating range 1 ml/h 1000 and resolution 0.1 ml/h. standard IEC 60601-2-24 determines that electronic balance with 0.0001 g should be used during calibration. Therefore, technical implementation analyzer for calibration periodic verification LPVIP Hospital was evaluated. Tests were performed considering tem three...