Wenbin Cao

ORCID: 0000-0003-3574-1944
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Power Systems Fault Detection
  • High-Voltage Power Transmission Systems
  • Magnetic Properties and Applications
  • Crystallization and Solubility Studies
  • X-ray Diffraction in Crystallography
  • HVDC Systems and Fault Protection
  • Geoscience and Mining Technology
  • Power Systems and Renewable Energy
  • Power Systems and Technologies
  • Smart Grid and Power Systems
  • Power Transformer Diagnostics and Insulation
  • Crystallography and molecular interactions
  • Silicon Carbide Semiconductor Technologies
  • Multilevel Inverters and Converters
  • Electric Motor Design and Analysis
  • Metal Alloys Wear and Properties
  • Computational Physics and Python Applications
  • Hydraulic and Pneumatic Systems
  • Microgrid Control and Optimization
  • Thermal Analysis in Power Transmission
  • Geophysical Methods and Applications
  • Hydrogen embrittlement and corrosion behaviors in metals
  • Real-time simulation and control systems
  • Engineering Diagnostics and Reliability
  • Microwave Imaging and Scattering Analysis

Huazhong University of Science and Technology
2016-2023

State Key Laboratory of Advanced Electromagnetic Engineering and Technology
2019

National Engineering Research Center of Electromagnetic Radiation Control Materials
2019

University of Shanghai for Science and Technology
2019

The urgent problem of the relaying protection in modern AC/DC hybrid connected grid and development wide area communication, information process intelligent technology powerfully promotes (WARP), which has become a research hotspot that attracts extensive attention. Originated from basic concept protection, this paper analyses advantages, effects functions protection. two main approaches to realize are on-line adaptive setting (OAS) principle fault element identification (FEI), introduced...

10.1186/s41601-016-0023-z article EN cc-by Protection and Control of Modern Power Systems 2016-08-11

In the transient process of power grid faults, transferring distortion current transformer (CT) can seriously affect relay protection performance. Under these conditions, it is difficult to analyze ferromagnetic characteristic magnetizing branch in equivalent circuit CT. The Jiles-Atherton hysteresis model (J-A model), which widely used digital simulations, accurately describe and saturation core characteristics; however, acquire parameters J-A transformers practical use still a challenging...

10.17775/cseejpes.2016.00049 article EN cc-by-nc-nd CSEE Journal of Power and Energy Systems 2016-12-07

When faults or disturbance occurs in AC/DC hybrid complex power grid, there have happened many generator, transformer and transmission line differential protection maloperation accidents caused by current (CT) saturation, which seriously threaten the safe stable operation of grid. As analytical analysis CT transient characteristics is very complex, it urgent to develop model can accurately simulate practical use. In this paper, different class (P, PR TPY) CTs use are taken do physical test....

10.1109/itec-ap.2017.8081041 article EN 2022 IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) 2017-08-01

In recent years, the zero-mode inrush current of high-impedance transformer with built-in high-voltage winding (T-Hin), which has large amplitude and decays slowly, causes misoperation zero-sequence overcurrent protection. Compared magnetizing current, waveform is inconsistent irregular, few researches have proposed mathematical analysis as well improved protection using characteristics. this paper, expression derived. Further considering parameter differences, T-Hin larger, tends to cause...

10.3390/en12152911 article EN cc-by Energies 2019-07-29

This paper proposes a hybrid UHVDC system dedicated for long-distance power transmission and back-to-back interconnection of the receiving region grids. The terminal is formed by LCC MMC in cascaded connection. combines merits hierarchical connection asynchronous interconnection, which optimizes network structure makes distribution grids more flexible. topology introduced detail. control strategy DC fault clearing are proposed. Finally, built PSCAD / EMTDC. simulation verifies effectiveness...

10.23919/icpe2019-ecceasia42246.2019.8797047 article EN 2019-05-01

When a switching-on transformer is energized, complex sympathetic inrush will flow through adjacent operating transformers, which may cause the protection misoperation in power system. At present, mathematical analysis of usually based on model that without load, engineering error. In this paper, analytical expressions flux linkages, source current and load for integration with possible power-source are presented. The models simulation established PSCAD. influencing factors key...

10.1109/sai.2017.8252268 article EN 2017 Computing Conference 2017-07-01

Large-scale electricity has fed into Central and Southern China through DC transmission lines. Any one of the lines suddenly outage will result in a large proportion power-shortage. Recently, there are many harmonic protection misoperations caused by AC disturbance, resulting line exit operation. Therefore, it is necessary to analyse effect disturbance on harmonics study methods for protections. In this study, based theory switching function, interaction AC–DC systems studied. The cause...

10.1049/joe.2018.8523 article EN cc-by-nd The Journal of Engineering 2018-10-24

Converter protection, including bridge differential protection and valve short‐circuit frequently malfunctions during the disturbance from an AC system, such as fault inrush current, which severely threatens safe stable operation of AC/DC hybrid power system. This paper analyzes cause maloperation based on mechanism analysis simulation tests. It is found that saturation current transformer in delta winding YD converter system main reason for this sort maloperation. To solve problem, proposes...

10.1002/tee.22473 article EN IEEJ Transactions on Electrical and Electronic Engineering 2017-07-28

During the inrush period, multiple misoperation accidents of differential protection transformers happened, which seriously threatened safe and stable operation power grid. In traditional malfunction analysis, only current process is considered, electromagnetic transient interaction between transformer other non-linear ferromagnetic components such as CT hardly considered. Here, variation rule waveform characteristic analysed, influence secondary load type on second harmonic proportion dead...

10.1049/joe.2018.8441 article EN cc-by-nd The Journal of Engineering 2019-01-04

High short-circuit impedance transformer is widely used because of its advantage in limiting current. Among the two types high transformers commonly used, high-voltage winding built-in type frequently occurs zero-sequence over-current protection maloperation during no-load closing, while another low-voltage series reactance rarely reported. The main difference between them lies structure. However, existing simulation models can hardly reflect difference. Through research, equivalent circuit...

10.1109/isgt-asia.2019.8881515 article EN 2019-05-01

In view of the misoperation inter-turn protection high voltage shunt reactor(HVSR) connected with submarine cable in offshore wind power project during conventional opening and closing operation, a comparative analysis principles different manufacturers analytical process operation sceneis are carried out. Based on analysis, two scenarios summarized, namely, zero-sequence source generated by saturation iron core is judged to be mistaken as an internal fault, measurement impedance decreases...

10.1109/iceemt59522.2023.10263206 article EN 2023-07-21

The excessive short-circuit current restricts the development of power grid. By using fast switch to dynamically change system topology structure during faults, flowing through conventional circuit breaker can be limit under switchable range, but application will affect relay protection. In this paper, flexible short-current suppression technology is introduced firstly. Then, influence on line protection, differential distance protection and zero-sequence discussed, optimized strategies are...

10.1109/acpee60788.2024.10532644 article EN 2022 7th Asia Conference on Power and Electrical Engineering (ACPEE) 2024-04-11

For the construction of smart grid, protection needs to be accurately measured, and current transformer correctly transfer transient process. The process nonlinear ferromagnetic elements mainly includes inrush CT saturation. Differential misoperation is rarely caused by a single factor. It involves coupling effect between In this paper, magnetizing sympathetic saturation are studied from aspects principle analysis digital simulation. Based on an accident, its impacts differential analyzed....

10.1109/itec-ap.2017.8081031 article EN 2022 IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) 2017-08-01

This paper analyses the mechanism of sympathetic inrush current converter transformer HVDC transmission system. The impacting factors current, including system impedance, closing angle and initial remnant flux incoming transformer, operating condition so on, are analysed utilizing on PSCAD/EMTDC soft. Based this, this proposed two identification methods for simulation proofs validity these methods.

10.1049/cp.2016.0503 article EN The 16th IET International Conference on AC and DC Power Transmission (ACDC 2020) 2016-01-01

The analysis of maloperation cases indicates that mal-operations the transformer differential protection caused by sympathetic inrush usually occur under combined action and current (CT) saturation. process characteristics mal-operation are analyzed. According to wave firstly increases maximum gradually then decays slowly, a new identification method is proposed, based on calculation fundamental component increment current. can identify quickly reliably adopt effective measures accordingly...

10.1109/pesgm.2018.8586413 article EN 2021 IEEE Power & Energy Society General Meeting (PESGM) 2018-08-01

In differential protection, the methods to correct amplitude and phase deviation of currents in primary secondary winding Y/Delta-connected transformer will weaken harmonic characteristics. Researchers have proposed inrush restraint criterion current directly. However, helping effect circulating delta may cause symmetrical or waveform distortion, reliability based on typical magnetizing characteristics be affected. This paper reveals generating mechanism, influencing factors current.

10.1109/ciycee49808.2020.9332530 article EN 2020 IEEE 1st China International Youth Conference on Electrical Engineering (CIYCEE) 2020-11-01

The circulating current in the D-winding may cause primary waveform distortion, and reliability of restraint criterion based on typical magnetizing inrush characteristics will be affected. with is sum current. Using to compensate can improve differential protection. When phase not saturated, about zero. Therefore, unsaturated replaced by opposite Based this, an engineering practical calculation method for proposed. In method, segmented currents are used replace Phasor analysis demonstrate...

10.1109/ciycee53554.2021.9676753 article EN 2021 IEEE 2nd China International Youth Conference on Electrical Engineering (CIYCEE) 2021-12-15

For the Y/D-connected transformer, if circulating current in D-winding can be obtained to compensate primary current, accuracy of inrush identification method will improved. At present, constructing algorithm is still insufficient. The mapping relationship between and unbalanced quantity (zero-mode zero-mode voltage, neutral point voltage) by deriving transformer differential equation this paper. A for based on proposed. In algorithm, only winding needs measured, there no requirement...

10.1109/powercon53785.2021.9697767 article EN 2021 International Conference on Power System Technology (POWERCON) 2021-12-08

This paper proposes an intelligent and digital improvement scheme for the GIS circuit breaker. Based on concept of integration primary secondary system, control system breaker is reconstructed by device. The conditional loop based cable relay integrated circuit. protection function, including three-phase inconsistency, anti-jump, over-current storage motor, carried out software. condition monitor, remote operation, interlock are realized device substation network.

10.1109/powercon53785.2021.9697797 article EN 2021 International Conference on Power System Technology (POWERCON) 2021-12-08

For the Inverter-Interfaced Distributed Generator (IIDG) access system, a ground fault occurred on 110 kV contact line, and zero-sequence current distribution both sides of line was analyzed by combining characteristics controlled source IIDG after fault, relationship between sequence quantities, neutral grounding method transformer capacity IIDG. Factors. The analysis points out that side mode determines zero sequences line; when system circuit breaker is disconnected, mainly affects...

10.1109/icopesa56898.2023.10141154 article EN 2022 International Conference on Power Energy Systems and Applications (ICoPESA) 2023-02-24

High voltage shunt reactor((referred to as HSR, the same below)) is an important equipment used absorb reactive power and limit overvoltage level in system. Its frequent fault inter-turn short circuit of winding. The traditional protection based on principle zero sequence component has been maloperation for many times site. Based analysis structure electrical characteristics this paper defines root cause protection, puts forward a new type scheme which composed core saturation criterion,...

10.1109/pandafpe57779.2023.10140998 article EN 2023-04-01
Coming Soon ...