J. Sousa

ORCID: 0000-0003-3678-7610
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Magnetic confinement fusion research
  • Nuclear Physics and Applications
  • Superconducting Materials and Applications
  • Particle accelerators and beam dynamics
  • Radiation Detection and Scintillator Technologies
  • Particle Detector Development and Performance
  • Advanced Data Storage Technologies
  • Fusion materials and technologies
  • Atomic and Subatomic Physics Research
  • Nuclear reactor physics and engineering
  • Plasma Diagnostics and Applications
  • Ionosphere and magnetosphere dynamics
  • Parallel Computing and Optimization Techniques
  • Radiation Effects in Electronics
  • Advancements in PLL and VCO Technologies
  • Embedded Systems Design Techniques
  • Network Time Synchronization Technologies
  • Distributed systems and fault tolerance
  • Advanced Frequency and Time Standards
  • Distributed and Parallel Computing Systems
  • Business and Management Studies
  • Sensor Technology and Measurement Systems
  • Gyrotron and Vacuum Electronics Research
  • CCD and CMOS Imaging Sensors
  • Advanced Electrical Measurement Techniques

Instituto Superior Técnico
2010-2023

University of Lisbon
2012-2022

University of Minho
2005-2022

Royal Military Academy
2020

Instituto de Engenharia de Sistemas e Computadores Investigação e Desenvolvimento
2006-2019

Uppsala University
2007-2016

Physikalisch-Technische Bundesanstalt
2016

University of Coimbra
2016

Culham Science Centre
2005-2012

Instituto Superior de Tecnologias Avançadas
2012

A new high efficiency, resolution, fast γ-ray spectrometer was recently installed at the JET tokamak. The is based on a LaBr3(Ce) scintillator coupled to photomultiplier tube. digital data acquisition system used allow spectrometry with event rates in excess of 1 MHz expected future DT plasmas. However, lower typical present day experiments, digitization can degrade energy resolution system, depending algorithms for extracting pulse height information from digitized pulses. In this paper,...

10.1063/1.3501386 article EN Review of Scientific Instruments 2010-10-01

High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out nuclear accelerators, combining a LaBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> (Ce) detector with dedicated hardware and software solutions based on digitization off-line analysis. Spectra measured up to 4 MHz, little or no degradation of the energy resolution, adopting pile rejection algorithm. The reported results represent step forward...

10.1109/tns.2013.2252189 article EN IEEE Transactions on Nuclear Science 2013-04-01

We here present the principles and main physics capabilities behind design of radial gamma ray spectrometers (RGRS) system for alpha particle runaway electron measurements at ITER. The diagnostic benefits from recent advances in gamma-ray spectrometry tokamak plasmas combines space high energy resolution a single device. RGRS as designed can provide information on particles time scale 1/10 slowing down ITER 500 MW full power DT scenario. Spectral observations 3.21 4.44 MeV peaks reaction...

10.1088/1741-4326/aa6f7d article EN Nuclear Fusion 2017-04-26

Abstract High-resolution γ-ray measurements were carried out on the Joint European Torus (JET) in an experiment aimed at accelerating 4 He ions MeV range by coupling third harmonic radio frequency heating to injected beam. For first time, Doppler broadening of peaks from 12 C(d, pγ) 13 C and 9 Be(α, nγ) reactions was observed interpreted with dedicated Monte Carlo codes based detailed nuclear physics processes. Information confined deuteron energy distribution inferred, energies as high 6...

10.1088/0029-5515/52/6/063009 article EN Nuclear Fusion 2012-04-24

Abstract The paper presents an overview of the design status Radial Neutron Camera (RNC), that, together with Vertical Camera, will provide, through reconstruction techniques applied to measured line-integrated neutron fluxes, time resolved measurement ITER and α-source profile (i.e. emissivity, neutrons emitted per unit volume). RNC is composed two subsystems, In-Port Ex-Port located, respectively, inside outside Plug Equatorial Port #01. subsystem in a more advanced stage since it has...

10.1007/s10894-022-00333-9 article EN cc-by Journal of Fusion Energy 2022-09-18

Anais do Congresso Neurocor: Liga Acadêmica de Neurologia, Neurocirurgia e Neurociências da UNIMAR Cardiologia (27646645) - Perspectiva Da Abordagem Por Cirurgia De Neuroendoscopia Para Manejo Minimamente Invasivo.

10.29327/ix-neurocor-463085.933550 article PT Anais do Congresso Neurocor 2025-01-01

Abstract The International Fusion Materials Irradiation Facility-DEMO-Oriented Neutron Source (IFMIF-DONES) is an advanced neutron source driven by accelerator, designed to generate high-energy neutrons for testing materials intended DEMO, the upcoming fusion reactor. Due plant’s complexity, a reliable central control system essential manage and supervise operations safely. This paper reviews recent progress in design of systems IFMIF-DONES, with focus on transition into full definition...

10.1088/1741-4326/adc1dd article EN cc-by Nuclear Fusion 2025-03-18

Objetivo: Analisar a eficácia e segurança da cirurgia endoscópica no tratamento do câncer gástrico, abordando suas indicações, vantagens, limitações impactos nos desfechos clínicos dos pacientes. Metodologia: Revisão bibliográfica realizada na base de dados PubMed-MEDLINE. Foram utilizados os termos busca "endoscopic surgery", "gastric cancer" "stomach neoplasms". incluídos estudos publicados entre 2024 2025, disponíveis em texto completo, inglês, que abordavam o tema proposto. Após...

10.70164/bjoh.v2i2.115 article PT cc-by-nc-nd 2025-03-24

Apesar dos avanços na área, a utilização do Design Thinking educação ainda é algo novo e desafiador. Este estudo tem como objetivo mapear produção científica sobre o área de em uma das principais bases dados, Web of Science – WoS, no período janeiro 2000 fevereiro 2024, analisando os registros que apresentam termos selecionados para busca, com base revisão literatura temática questão. Como percurso metodológico, foi realizada análise descrição bibliométrica suporte investigações indexadas -...

10.33871/23594381.2025.23.1.9363 article PT Revista Ensino & Pesquisa 2025-04-25

The efficient vertical stabilization (VS) of plasmas in tokamaks requires a fast reaction the VS controller, for example, after detection edge localized modes (ELM). For controlling effects very large ELMs new digital control hardware, based on Advanced Telecommunications Computing Architecture™ (ATCA), is being developed aiming to reduce loop cycle (down an optimal value 10μs) and improve algorithm performance. system has 1 ATCA™ processor module up 12 modules, each one with 32 analog input...

10.1063/1.2221906 article EN Review of Scientific Instruments 2006-10-01

A multi-input-multi-output controller for the plasma vertical stabilization was implemented and installed on Joint European Torus tokamak. The system can attain a control-cycle time of approximately 30 ¿s using ×86 multi-core processors but targets 10 via Field Programmable Gate Array (FPGA) based processing. hardware, complying with Advanced Telecommunications Computing Architecture (ATCA) standard, in-house designed to achieve required performance consists of: total 6 synchronized ATCA...

10.1109/tns.2010.2042068 article EN IEEE Transactions on Nuclear Science 2010-04-01
Coming Soon ...