- Cardiac pacing and defibrillation studies
- Cardiac Arrhythmias and Treatments
- Cardiac Valve Diseases and Treatments
- Atrial Fibrillation Management and Outcomes
- Dental Erosion and Treatment
- Acute Myocardial Infarction Research
- Central Venous Catheters and Hemodialysis
- Ovarian cancer diagnosis and treatment
- Cardiac electrophysiology and arrhythmias
- Neurological disorders and treatments
- Coronary Interventions and Diagnostics
- Vascular anomalies and interventions
- Cardiomyopathy and Myosin Studies
- Dental materials and restorations
- Antiplatelet Therapy and Cardiovascular Diseases
- Cardiac Ischemia and Reperfusion
- Cardiac Fibrosis and Remodeling
- Chronic Obstructive Pulmonary Disease (COPD) Research
- Systemic Sclerosis and Related Diseases
- ECG Monitoring and Analysis
- Cancer, Lipids, and Metabolism
- Neuroscience and Neural Engineering
- Mechanical Circulatory Support Devices
- Transplantation: Methods and Outcomes
- Dental Health and Care Utilization
Medical University of Warsaw
2015-2025
Wroclaw Medical University
2025
Medical University of Silesia
2019
Poznan University of Medical Sciences
2008-2015
Wojskowy Instytut Medycyny Lotniczej
2012
In patients with Ovarian Cancer (OvCa) exosomes released by tumor cells are present in the plasma and could be involved progression. This study examines association between exosome presence/protein content of OvCa disease outcome, response to standard therapy and/or tumorresistance therapies studied at diagnosis also serially during after therapy.Exosomes were purified from patients' (n=22), benign tumors (n=10) or healthy controls (NC) using ultracentrifugation. Exosomes visualized scanning...
Fluoride has remained the most important ingredient in prevention of tooth decay for many years. Therefore, fluoride prophylaxis should be highly individualized to provide patients with maximum benefits while minimizing risk toxic effects. This study aims compare degree ion release from two commercially available dental gels (Fluormex and Fluor Protector Gel) five different physiological solutions as well their effect on pH. The concentration ions pH tap water, distilled demineralized NaCl,...
Background Despite a substantial progress in diagnosis and therapy, acute myocardial infarction (MI) is major cause of mortality the general population. A novel insight into pathophysiology obtained by studying gene expression should help to discover biomarkers MI suggest strategies therapy. The aim our study was establish patterns leukocytes from patients. Methods Results Twenty-eight patients with ST-segment elevation (STEMI) were included. blood collected on 1st day infarction, after 4–6...
A successful implantation of transcatheter aortic valve was performed in a highrisk 85-year-old female with severe symptomatic stenosis bicuspid (BAV) [ Panel ] and tight lesions left anterior descending (LAD) circumflex artery (LCx). Until recently, BAV remained contraindication to replacement …
The aim of this study was to assess the sensitivity and specificity HE4 in detecting differentiating between types I II epithelial ovarian cancer (EOC) comparison with CA125.We measured CA125 serum concentrations 206 samples taken from patients operated Gynecologic Oncology Department due tumors. Ovarian confirmed 89 cases divided into type II. 52 healthy without any gynecological disease formed control group. for EOC detection both evaluated CA125.The were significantly higher than...
Background: The use of subcutaneous implantable cardioverter-defibrillators (S-ICD) has been growing in Poland since 2014. Polish Registry S-ICD Implantations was run by the Heart Rhythm Section Cardiac Society between May 2020 and September 2022 to monitor implementation that therapy Poland. Aims: To investigate present state-of-the-art implantation Methods: Implanting centers reported clinical data patients undergoing implantations replacements, including age, sex, height, weight,...
Objectives:The aim of this study was to compare and evaluate the quality CA125, HE4, logistic regression model based on CA125 ROMA algorithm in preoperational differential diagnostics ovarian tumors. Material methods:To 110 patients enrolled.Based histopatological examination removed tumors, they were divided into group (56 cancer patients) control one (nonmalignant 54 patients).Serum HE4 concentrations measured following a standard procedure.Results: A commonly accepted referential value...
Bleeding negatively affects prognosis and adherence to antiplatelet therapy after acute coronary syndromes (ACSs). The potential association of on-aspirin platelet reactivity bleeding is not established. We sought determine whether low (LAPR) associated with events compliance in patients ACSs receiving stenting. On-aspirin was measured by the VerifyNow™ Aspirin assay (Accumetrics Inc., San Diego, CA, USA) 531 ACS. Cut-offs for LAPR were calculated receiver-operating characteristic curve...
The Micra transcatheter pacing system (TPS) is a miniaturized, single-chamber pacemaker system. Study reported herein an initial experience with implantation of the TPS.The leadless was implanted in 10 patients standard indications for permanent implantation. All hospitalization costs were calculated all patients.The mean age 75 ± 7.1 years, 6 men and 4 women. Four had atrial fibrillation as basal rhythm sinus rhythm. at least one relative contraindication that precluded use traditional Mean...
The frequency of cardiac implantable electronic device (CIED) implantations is constantly increasing. Pericardial effusion (PE) and tricuspid regurgitation (TR) may occur after CIED implantation. aim the present study to evaluate prevalence risk factors for new occurrences or progression TR PE early implantation.This an on-going, single-center, observational patients their first implantation, with echocardiographic evaluation within 60 days before 7 procedure. Data are presented 110...
A 57-year-old man with an AAI pacemaker was referred to the hospital due suspicion of atrial lead failure. The implanted 9 years earlier because sick sinus syndrome. inserted by puncture right subclavian vein pocket located at same site. Currently patient presented mild asymptomatic bradycardia 50 bpm. For 3 months he had noticed pectoral muscle contractions that depended on body position. Pacemaker control revealed impedance exceeding 2000 Ohms and lack either proper sensing or stimulation....
Single-lead for implantable cardioverter-defibrillator (ICD) with floating atrial sensing dipole is a new diagnostic tool the potential advantage in terms of arrhythmia discrimination. We sought to determine whether right heart size and position influence sensing.Atrial (AS) amplitude was measured during implantation (PP, periprocedural), predischarge (IHFU, in-hospital follow-up) 3-6 months after procedure (AFU, ambulatory follow-up). Results were related atrium (RA) on basis chest X-ray...
Bleeding in the setting of acute coronary syndromes (ACS) has negative prognostic implications. We sought to determine impact different levels on-treatment platelet reactivity (PR) ADP on both bleeding and ischemic events ACS patients receiving stenting. PR was measured with VerifyNow P2Y12 assay (Accumetrics, San Diego, CA) 374 standard dual antiplatelet therapy. Patients were stratified into three tertiles according increasing values reaction units first tertile defined as low, second...
Transvenous lead extraction (TLE) is recommended in cases of local and systemic infections related to cardiac implantable electronic devices (CIEDs). Additionally, TLE indicated the event damage or CIED malfunction. The procedure associated with a risk life-threatening complications.The aim EVO registry was assess safety efficacy birotational Evolution tool usage.This study prospectively conducted 8 high-volume implantation centers Poland. included 133 patients aged 63.5 ±15.1 years, 76.69%...
The recent introduction of an entirely subcutaneous implantable cardioverter-defibril-lator (S-ICD) represents important progress in the defibrillation technology towards a less invasive approach. This is single-center observational study S-ICD implantations Poland.The was implanted 11 patients with standard indications for ICD. Patients whom device were evaluated adverse events and function at hospital discharge. All hospitalization costs calculated summed up all patients. Costs divided...