Jiankang Zhou

ORCID: 0000-0003-4279-1982
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Infrared Target Detection Methodologies
  • Calibration and Measurement Techniques
  • Remote-Sensing Image Classification
  • Optical and Acousto-Optic Technologies
  • Optical Polarization and Ellipsometry
  • Optical Systems and Laser Technology
  • Cancer-related molecular mechanisms research
  • Advanced Measurement and Detection Methods
  • CCD and CMOS Imaging Sensors
  • Advanced optical system design
  • Advanced Sensor Technologies Research
  • Sparse and Compressive Sensing Techniques
  • Photoacoustic and Ultrasonic Imaging
  • Satellite Image Processing and Photogrammetry
  • Optical Coatings and Gratings
  • Image and Signal Denoising Methods
  • Adaptive optics and wavefront sensing
  • Advanced Data Compression Techniques
  • nanoparticles nucleation surface interactions
  • Image Processing Techniques and Applications
  • Chemical Thermodynamics and Molecular Structure
  • Sepsis Diagnosis and Treatment
  • Photonic and Optical Devices
  • Advancements in Solid Oxide Fuel Cells
  • Radiomics and Machine Learning in Medical Imaging

Tsinghua University
2024-2025

University of Shanghai for Science and Technology
2023-2025

Nanjing University
2025

Collaborative Innovation Center of Advanced Microstructures
2025

National Laboratory of Solid State Microstructures
2025

Soochow University
2010-2024

Central South University
2024

Second Xiangya Hospital of Central South University
2024

State Key Laboratory of Biotherapy
2023

Sichuan University
2023

It has been supposed that the interplay of elasticity and activity plays a key role in triggering non-equilibrium behaviors biological systems. However, experimental model system is missing to investigate spatiotemporally dynamical phenomena. Here, an active chain, where eccentric-disks are linked by spring, designed study activity, elasticity, friction. Individual chain exhibits longitudinal transverse motions; however, it starts self-rotate when pinning one end self-beat clamping end. In...

10.1063/5.0217158 article EN The Journal of Chemical Physics 2024-08-14

Abstract Background Multiple cell death modalities are implicated in sepsis pathobiology. However, the clinical relevance of NINJ1, a key mediator plasma membrane rupture during lytic death, progression and outcomes has remained poorly explored. Methods Circulating NINJ1 levels were measured 116 septic ICU patients, 16 non-septic controls, healthy controls. Comparative analysis serum across these groups was performed. Correlations between disease severity scores (SOFA, APACHE II) as well...

10.1097/shk.0000000000002460 article EN Shock 2024-08-28

Thin Film Growth In article number 2404829, Wanyu Ding, Zixi Wang, and co-workers established a three-layer NiCr/NiSi thin-film thermocouple temperature measurement system in TiO2 film growth processes, to measure the gradient from surface substrate. The of substrate was about 132.05 °C, while difference between could reach 144.71 °C.

10.1002/smll.202570004 article EN Small 2025-01-01

Objective: Previous studies suggest that the combination of robot-assisted training with other concurrent tasks may promote functional recovery and improvement better than single task. It is well-established rehabilitation effective. This study aims to characterize neural mechanisms inter-regional connectivity changes associated parallel interactive tasks. Methods: Twenty-five healthy young adults (12 females 13 males) participated in three number-related cognitive-motor categorized by...

10.1089/brain.2024.0043 article EN Brain Connectivity 2025-02-20

Abstract Quantum dots (QDs) are semiconductor nanocrystals with superior quantum efficiency, narrow emission linewidths, and tunable bandgaps, making them valuable in optoelectronics. However, their commercialization is hindered by instability under stress environmental concerns related to heavy metal leaching. To address these issues, advanced encapsulation strategies, particularly using inorganic glass matrices (silicate, phosphate, borate), crucial. This review examines the...

10.1002/crat.202500030 article EN Crystal Research and Technology 2025-05-24

In the general analysis of thin-film growth processes, it is often assumed that temperature film surface same as substrate. However, a gradient exists between and Using TiO

10.1002/smll.202404829 article EN Small 2024-10-10

Accurate calibration of the Seebeck coefficient is crucial for reliable temperature measurements using thin‐film thermocouples. In this study, NiCr/NiSi thermocouples investigated precise measurements. Using magnetron sputtering method, a series film are prepared and their coefficients obtained through standard procedures. The results demonstrate good consistency reproducibility thermoelectric output within range 0–505 °C. Notably, remain nearly constant regardless changes in top bottom...

10.1002/pssa.202400653 article EN physica status solidi (a) 2024-12-13

Target detection is one of most important applications in remote sensing. Nowadays accurate camouflage target distinction often resorted to spectral imaging technique due its high-resolution spectral/spatial information acquisition ability as well plenty data processing methods. In this paper, hyper-spectral together with divergence measure method used solve problem. A self-developed visual-band device adopted collect cubes certain experimental scene before divergences are worked out so...

10.1117/12.2257938 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2017-01-05

A two-mirror catadioptric system with corrective lens groups is adopted in the remote sensing camera of microsatellite. Compared refractive system, it has advantage that its performance hardly influenced by thermal environment. Stray light results image blur and contrast reduction camera. It necessary to analyze control it. In traditional way, stray can be effectively suppressed a long baffle, which not suitable for microsatellites limited space. And compact one high designed. First all,...

10.1117/12.838169 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2009-11-04

The conical diffraction Offner hyperspectral imaging spectrometer (CDO-HIS) is a calibrator for monitoring the radiation stability of an ocean color sensor. adopts structure configuration (CDO-CF), containing convex blazed grating to produce nearly nondistortion and high spectral fidelity image. theory analysis discussed introduced instrument design. optimization procedure design results CDO-HIS are provided based on ideas, which show benefits employment CDO-CF. laboratory characterization...

10.1364/ao.58.007298 article EN Applied Optics 2019-09-10

Modulation Transfer Function (MTF) is the spatial frequency response of imaging systems and now develops as an objective merit performance for evaluating both quality lens camera. Slanted-edge method its principle measuring MTF digital camera are introduced in this paper. The setup software testing respectively established developed. Measurement results with different tilt angle knife edge compared to discuss influence angle. Also carefully denoise image performed decrease noise sensitivity...

10.1117/12.869937 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2010-11-03

Remote sensing imaging spectrometry is widely used in fields such as atmosphere survey, mineral discovery, forest surveillance and so on. The signal-to-noise ratio (SNR) of an spectrometer reflects its radiance response relates closely to acquired image quality. Due limited throughput, current slit-based hyperspectral stands a dilemma between spectral resolution SNR. For airborne spectrometer, the SNR required be order hundred while intentional requirement met. evaluation significance...

10.1109/icsai.2012.6223191 article EN 2012-05-01

Offner spectrometer is widely applied in hyperspectral imaging spectrometers, which the design, fabrication, and testing of convex gratings are crucial to ensure spectral performance whole system. A conical diffraction proposed with range 400 900 nm, resolution 5 slit length 1 mm, dispersive width 10 mm. finite-element analysis adopted optimize groove parameters blazed grating that used aforesaid spectrometer. Holographic scan ion beam etching method employed fabricate such grating....

10.1117/1.oe.58.2.025109 article EN Optical Engineering 2019-02-26

Spectral calibration of imaging spectrometer plays an important role for acquiring target accurate spectrum. There are two spectral types in essence, the wavelength scanning and characteristic line sampling. Only calibrated pixel is used methods he response function (SRF) constructed by itself. The different can be generated monochromator. SRF adjacent pixels one sampling methods. And illuminated narrow spectrum center exactly known. result comes from method precise, but it takes much time...

10.1117/12.2038150 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2013-12-19

The designed hyperspectral imaging system is composed of three main parts, that is, optical subsystem, electronic subsystem and capturing subsystem. And a three-dimensional "image cube" can be obtained through push-broom. fore-optics commercial-off-the-shelf with high speed continuous zoom ratios. Since the dispersive part based on Offner relay configuration an aberration-corrected convex grating, power light collection variable view field are obtained. holographic recording parameters...

10.1117/12.838159 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2009-11-04

Star trackers determine attitude by identifying stars imaged on the image sensor via an optical system whose performance is required to meet star identification algorithm. The method parameters of proposed based These include focal length, aperture, and field view (FOV). Aberration correction requirements are also analyzed. Pyramid algorithm utilized in this paper investigated. Some improved approaches presented for map processing, onboard catalog organization identification. A link table...

10.1117/12.806698 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2008-12-03

Frame transfer area-array CCD camera is the perfect solution for high-end real-time medical, scientific and industrial applications because it has characteristics of high fill factor, low dark current, resolving power, sensitivity, linear dynamic range electronic shutter capability. Time sequences frame have two compact segments: driving signal processing sequences. Proper working sensor lies on good while accurate ensures quality image. The relationship among time complex precise....

10.1117/12.756409 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2007-11-15

After alignment of an imaging spectrometer, the image a special wavelength should in theory strictly meet with design value and is focused on certain column CCD focal plane. Since spectrometer usually used spatial or aerial environment, optical components detector will departure from regulated place leads to focusing onto deflected position plane spectral direction. onboard readjustment inaccurate unavailable, equivalent task be performed by post processing method. In this paper, we present...

10.1117/12.835557 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2009-07-03
Coming Soon ...