Karlos Zepeda

ORCID: 0009-0003-9023-0503
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Orthopaedic implants and arthroplasty
  • Total Knee Arthroplasty Outcomes
  • Orthopedic Infections and Treatments
  • Knee injuries and reconstruction techniques
  • Shoulder Injury and Treatment

Hospital for Special Surgery
2025

Touro College
2021-2024

Sapienza University of Rome
2022

Revision knee arthroplasty presents a number of challenges, including management bone loss. The goal in managing moderate to large defects is fixation that sufficient enough allow early weight-bearing. purpose this study was describe the surgical technique and clinical radiographic outcomes patients treated with porous tantalum metaphyseal cones combination long uncemented diaphyseal-engaging stems manage tibial loss revision total (TKA).Thirty-six aseptic TKAs were performed at our...

10.1186/s43019-022-00141-7 article EN cc-by Knee Surgery and Related Research 2022-03-10

Abstract Background In total knee arthroplasty, the normal kinematics of may not be restored solely based on preoperative gait, fluoroscopic-based, and dynamic radiostereometric analyses. Surgical technique case presentation This note introduced a 69-year-old male patient who sustained post-traumatic osteoarthritis his right knee. He underwent robot-assisted arthroplasty anatomical reproduction stability during swing phase gait. The kinematic alignment was simply achieved within an...

10.1186/s42836-023-00191-6 article EN cc-by Arthroplasty 2023-06-05

Although Total Knee Arthroplasty (TKA) is a successful procedure, significant number of patients are still unsatisfied, reporting instability at the mid-flexion range (Mid-Flexion Instability-MFI). To avoid this complication, many innovations, including load sensors (LS), have been introduced. The intraoperative use LS may facilitate balance knee during entire motion to MFI postoperatively. objective study was perform Gait Analysis (GA) evaluation series who underwent primary TKA using...

10.3390/jfmk7010023 article EN cc-by Journal of Functional Morphology and Kinesiology 2022-02-18

Gait analysis was used to evaluate knee kinematics in patients who underwent successful primary total arthroplasty (TKA) using two modern bi-cruciate substituting designs. The joint balanced intraoperatively real-time sensor technology, developed provide dynamic feedback regarding stability and tibiofemoral load. authors hypothesized that major differences exist gait parameters between healthy controls post-TKA patients.Ten TKA designs were evaluated at a minimum of 9 months postoperatively...

10.1186/s40634-023-00567-2 article EN cc-by Journal of Experimental Orthopaedics 2023-01-01
Coming Soon ...