Hui Zhong

ORCID: 0000-0001-5214-9235
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Ultrasound Imaging and Elastography
  • Fusion materials and technologies
  • Photoacoustic and Ultrasonic Imaging
  • Ultrasound and Hyperthermia Applications
  • Graphite, nuclear technology, radiation studies
  • Ultrasonics and Acoustic Wave Propagation
  • Advanced Image and Video Retrieval Techniques
  • Medical Image Segmentation Techniques
  • Hepatocellular Carcinoma Treatment and Prognosis
  • Nuclear Materials and Properties
  • Radiation Shielding Materials Analysis
  • Image and Object Detection Techniques
  • Olfactory and Sensory Function Studies
  • Advanced Antenna and Metasurface Technologies
  • Radiomics and Machine Learning in Medical Imaging
  • Cholangiocarcinoma and Gallbladder Cancer Studies
  • Image Processing and 3D Reconstruction
  • Visual Attention and Saliency Detection
  • Ultrasound and Cavitation Phenomena
  • Electric Motor Design and Analysis
  • Infrared Target Detection Methodologies
  • Blind Source Separation Techniques
  • Advanced X-ray Imaging Techniques
  • Crystallography and Radiation Phenomena
  • Machine Fault Diagnosis Techniques

Xi'an Jiaotong University
2005-2023

Chinese PLA General Hospital
2022

Stony Brook University
2019-2021

State University of New York
2021

Brookhaven National Laboratory
2018-2020

Chinese People's Liberation Army
2020

Shandong University
2018

Harbin Institute of Technology
2018

University of Shanghai for Science and Technology
2017

Institute of Microelectronics
2017

Abstract Metallic mesh is a significant candidate of transparent conductive electrodes (TCEs) to substitute the current state‐of‐the‐art material indium tin oxide for optoelectronic devices. However, there remains challenge fabricate stable and good‐visibility metallic with low‐cost copper (Cu) material. A Cu electrode (on glass) high absolute transmittance ≈82% combined an adjustable low electrical resistance ≈0.2 Ω sq −1 total light reflectance 8.7% demonstrated here. The TCE shows...

10.1002/aelm.201800156 article EN Advanced Electronic Materials 2018-08-06

Objective To develop and validate an ultrasonic radiomics model for predicting the recurrence differentiation of hepatocellular carcinoma (HCC). Convolutional neural network (CNN) ResNet 18 Pyradiomics were used to analyze gray-scale-ultrasonic images predict prognosis degree HCC.Methods This retrospective study enrolled 513 patients with HCC who underwent preoperative grayscale-ultrasonic imaging, their clinical characteristics observed. Patients randomly divided into training (n = 413)...

10.1080/02656736.2022.2062463 article EN cc-by International Journal of Hyperthermia 2022-04-17

This study aims at a sound field calculation for the spherical-section phased array and an optimization algorithm focus patterns of ultrasound surgery. An efficient formula represented as explicit expression is derived by strategies projection binomial expansion. based on genetic constructed suitable fitness function selection strategies. The simulation results 256-element show capability controlling accurately effectively with combined method made up algorithm. single focus, multiple foci,...

10.1109/tuffc.2005.1509786 article EN IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 2005-08-01

The axial resolution of ultrasonic imaging is confined by the temporal width acoustic pulse generated transducer, which has a limited bandwidth. Deconvolution can eliminate this effect and, therefore, improve resolution. However, most methods perform deconvolution scan line line, and therefore information embedded within neighbor lines unexplored, especially for those materials with layered structures such as blood vessels. In paper, joint sparse representation model proposed to increase...

10.1109/tuffc.2016.2609141 article EN IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 2016-09-13

The NT-02 neutrino physics target made of the isotropic graphite grade produced neutrinos for MINOS and MINERVA high-energy experiments. segmented, 95-cm-long was bombarded with a 340 kW, Gaussian 1.1 mm sigma beam 120 GeV protons reaching $6.516\ifmmode\times\else\texttimes\fi{}{10}^{20}$ on peak fluence $8.6\ifmmode\times\else\texttimes\fi{}{10}^{21}\text{ }\text{ }\mathrm{protons}/{\mathrm{cm}}^{2}$. Reductions in detected events during experiment were attributed to radiation-induced...

10.1103/physrevaccelbeams.22.041001 article EN cc-by Physical Review Accelerators and Beams 2019-04-08

The use of sagittally bent asymmetric Laue crystals in horizontally focusing monochromators for high-energy synchrotron X-rays necessitates simulation the X-ray reflectivity by such crystals. Based on theory lattice distortion diffraction plane crystals, a lamellar model was developed to predict their rocking curves. experimentally verified rocking-curve measurements from various reflections silicon four representative orientations, radii, using 67 keV energy.

10.1107/s0108767302016835 article EN Acta Crystallographica Section A Foundations of Crystallography 2002-12-21

The effects of proton beams irradiating materials considered for targets in high-power accelerator experiments have been studied using the Brookhaven National Laboratory's (BNL) 200 MeV linac. A wide array and alloys covering a range atomic number (Z) are being scoped by community prompting BNL studies to focus on representing each distinct range, i.e. low-Z, mid-Z high-Z. low includes such as beryllium graphite, midrange Ti-6Al-4V, gum metal super-Invar finally high-Z pure tungsten...

10.1103/physrevaccelbeams.21.053001 article EN cc-by Physical Review Accelerators and Beams 2018-05-29

Tumor recurrence is an abomination for hepatocellular carcinoma (HCC) patients receiving local treatment.The aim of the study was to build a hybrid machine learning model recommend optimized first treatment (laparoscopic hepatectomy [LH] or microwave ablation [MWA]) naïve single 3-5-cm HCC based on early (ER, ≤2 years) probability.This retrospective collected 20 semantic variables 582 (LH: 300, MWA: 282) from 13 hospitals with at least 24 months follow-up. Both groups were divided into...

10.1159/000522123 article EN cc-by-nc Liver Cancer 2022-01-01

This paper discusses the fabrication and characterization of 3.5-MHz single-element transducers for therapeutic applications in which active elements are made hard lead-free BNT-based commercial PZT (PZT-841) piezoceramics. Composition (BiNa0.88K0.08Li0.04)0.5(Ti0.985Mn0.015)O3 (BNKLT88-1.5Mn) was used to develop piezoelectric ceramic. Mn-doped samples exhibited high mechanical quality factor ( ) 970, thickness coupling coefficient 0.48, a dielectric constant 310 (at 1 kHz), depolarization...

10.1109/tuffc.2018.2793874 article EN IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 2018-01-15

With the wide adoption in surveillance video analysis, some pixel-domain analysis methods are not only used academia but also garnering attention of industry. However, because increasing data volume video, how to analyze and browse videos a fast effective way has continued present an intractable problem practical applications. Therefore, synopsis method based on blank frame deletion compressed domain is proposed this paper achieve browsing. Our main contributions are: 1) An algorithm...

10.1145/3126686.3126778 article EN 2017-10-23

This paper presents a hierarchical approach for fast and robust ellipse extraction from images. At the lowest level, image is described as set of edge pixels, which line segments are extracted. Then, that potential candidates elliptic arcs linked to form arc according connectivity curvature relations. After that, belong same grouped together. Finally, statistical method, namely RANSAC, applied fit ellipses. method does not need high dimensional parameter space like Hough transform based...

10.1109/icip.2007.4379836 article EN 2007-01-01

The broad applications of manipulation electromagnetic waves (EMWs) in imaging, detection, communication, and electronic countermeasures have drawn extensive attention to the metasurface. In these applications, maintaining transparency visible light is challenging, especially when high transmittance infrared band also required, not mention substrate a nondevelopable surface. Although ITO-based metasurfaces can transmit light, ITO cannot has poor mechanical properties, coupled with...

10.1021/acsaelm.1c00699 article EN ACS Applied Electronic Materials 2021-10-14

Saliency detection has been a hot topic in computer vision. Among existing approaches, representative one is to use the convex hull prior find salient object image; and there are many variants that based on prior. Most of these works used single center construct map, while few attention made multiple centers. In this paper, we propose multi-center solution for saliency detection. Particularly, our also integrates two non-trivial optimizations: obtaining an enhanced global color distinction...

10.1109/icassp.2018.8461285 article EN 2018-04-01

10.1016/j.nimb.2020.06.018 article EN publisher-specific-oa Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2020-06-24

Deconvolution can improve the resolution of ultrasound system since effect point spread function be removed. Traditional methods carry out deconvolution line by line, so neighborhood information are unused. A joint sparse model is proposed in this work to discover layered structure images. The joints axial with a lateral constraint. was tested on simulation and real data, results support enhanced performance terms resolution.

10.1109/ultsym.2015.0323 article EN 2017 IEEE International Ultrasonics Symposium (IUS) 2015-10-01

Real-time dynamic monitoring of cavitation is essential for the safety and efficiency high intensity focused ultrasound (HIFU) therapy. Unlike pulse-echo imaging, which can only be use while HIFU turned off, passive acoustic mapping (PAM) enable during exposure. But conventional used PAM has low resolution interference artifacts. For this, a unique algorithm that combines frequency-sum beamforming with robust Capon beamformer (FS-RCB-PAM) was proposed in this study.

10.1109/ultsym.2017.8091866 article EN 2017 IEEE International Ultrasonics Symposium (IUS) 2017-09-01

This paper proposed a precise tubular permanent magnet linear motor(PMLM) iron loss calculation model, in which the effect of motor primary structure and harmonic were taken into account. The simulation model was built by finite element method. Base on no-load field map each point magnetic density waveform changes provided. Combination method this paper, more accurate core PMLM obtained influence speed stator discussed. verified measured data.

10.1109/spec.2018.8635994 article EN 2018-12-01

In order to overcome the shortcomings of traditional vision methods in field vehicle driving assistance, include visible light imaging system is vulnerable influence illumination conditions and small view (FOV) has a large blind area, this paper proposed an environmental perception method based on ultra-wide FOV infrared system. However, due compression Ultra-wide lens, target occupies fewer pixels, detection distance greatly limited. Therefore, studies feasibility application auxiliary from...

10.1117/12.2564386 article EN Sixth Symposium on Novel Optoelectronic Detection Technology and Applications 2020-04-17
Coming Soon ...