Xin Yang

ORCID: 0000-0001-5702-9451
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Optical Imaging and Spectroscopy Techniques
  • Photoacoustic and Ultrasonic Imaging
  • Advanced Chemical Sensor Technologies
  • Geomagnetism and Paleomagnetism Studies
  • Characterization and Applications of Magnetic Nanoparticles
  • Electrical and Bioimpedance Tomography
  • Image and Object Detection Techniques
  • Microfluidic and Bio-sensing Technologies
  • Music and Audio Processing
  • Spectroscopy Techniques in Biomedical and Chemical Research
  • Microfluidic and Capillary Electrophoresis Applications
  • Infrared Thermography in Medicine
  • Advanced Fluorescence Microscopy Techniques
  • Speech and Audio Processing
  • Advanced Measurement and Detection Methods
  • Industrial Vision Systems and Defect Detection
  • Hearing Loss and Rehabilitation
  • Medical Imaging Techniques and Applications
  • bioluminescence and chemiluminescence research
  • Innovative Microfluidic and Catalytic Techniques Innovation

Shandong Institute of Automation
2011-2024

Chinese Academy of Sciences
2010-2024

University of Chinese Academy of Sciences
2023-2024

Hebei University of Technology
2007-2014

Tsinghua University
2008

Magnetic particle imaging (MPI) uses nonlinear response signals to noninvasively detect magnetic nanoparticles in space, and its quantitative properties hold promise for future precise treatments. In reconstruction, the system matrix based method necessitates suitable regularization terms, such as Tikhonov or non-negative fused lasso (NFL) regularization, stabilize solution. While NFL offers clearer edge information than it carries a biased estimate of <italic...

10.1109/tmi.2024.3383468 article EN cc-by IEEE Transactions on Medical Imaging 2024-04-01

We review the current state-of-the-art of bioluminescence tomography (BLT) imaging, which is an emerging technique for monitoring and assessment biological processes in vivo. The aim BLT to reconstruct 3-D distribution internal bioluminescent source using boundary measurements acquired by a imaging system. Thus, becomes task solving inverse problem with appropriate photon propagation model. In this paper, we discuss recent advances models transport, detail techniques reconstructions....

10.1109/jstqe.2011.2178234 article EN IEEE Journal of Selected Topics in Quantum Electronics 2011-12-06

Bioluminescence tomography (BLT) has become a powerful tool for whole-body small animal imaging. In this contribution, an adaptive improved element free Galerkin method (IEFGM) is presented to perform quantitative reconstruction of the internal light source using quasi- or multi-spectral information, which not only can avoid time-consuming mesh generation but also reduce ill-posedness BLT effectively. algorithm, be largely enhanced by technology based on posteriori error estimation. Finally,...

10.1364/oe.17.021925 article EN cc-by Optics Express 2009-11-16

Magnetic particle imaging (MPI) is a rapidly developing medical modality, which uses the nonlinear response of superparamagnetic iron oxide nanoparticles to applied magnetic field image their spatial distribution. Background signal main source artifacts in MPI, mainly includes harmonic interference and Gaussian noise. For different sources noise, existing methods directly process time domain achieve enhancement or construct system function by frequency obtain high-quality reconstructed...

10.1109/tetci.2023.3337342 article EN cc-by-nc-nd IEEE Transactions on Emerging Topics in Computational Intelligence 2023-12-12

Imaging modality of radionuclides has been enriched by an optical approach, Cerenkov luminescence tomography (CLT). Referred to the traditional radionuclide imaging, such as positron emission (PET) or single photon computed (SPECT), any incremental improvement CLT imaging is consistent with application information needs. In this contribution, paper presents l <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> -regularized method for...

10.1109/iembs.2011.6091521 article EN Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2011-08-01

Odor pollution means a distinctive gas that is offensively unpleasant and harmful for the living conditions, not only disturbing social activities but also being harm human. For character of odor pollution, kind detecting system based on photoionization detector (PID) has been developed. The capillary column used as separate device PID detector. From stability experiment sensor, standard deviation 5.88×10 -3 , relative 0.14%. Furthermore, experimental results sample calibration illustrated...

10.4028/www.scientific.net/amm.635-637.698 article EN Applied Mechanics and Materials 2014-09-01

A kind of online or portable odor detector is needed for continuously monitoring the concentration and tracing source which one atmosphere pollution. Combining gas chromatograph (GC) micro-fluidic chip technology, we present a detecting system using separator photo ionization (PID) sensor. The 115×60×6mm chip, etched micro channel 1mm diameter 1.8m length inside, filled by polyethylene glycol as stationary phase according to type character odor. Respectively stainless steel packed columns,...

10.4028/www.scientific.net/amr.1010-1012.446 article EN Advanced materials research 2014-08-01

Tomographic bioluminescence imaging suffers from poor robustness, since it is severely affected by selection of regularization parameter (RP) and initialization for source distribution. In this paper, a global-inexact-Newton based reconstruction methodology, which regularized dynamic sparse term, demonstrated in vivo tomographic imaging. The novel method can enhance higher reliability efficiency. Mouse experimental reconstructions were performed to validate the proposed method. These results...

10.1109/iembs.2010.5626166 article EN 2010-08-01

Niche Genetic Algorithm (NGA) is proposed to recognize a disconnected nonparametric curve from noisy binary image. The fitness function used in the NGA derived hypothesis: Human Visual Tradition Model (HVTM). Sharing based niche technique and elite-preserving strategy are utilized preserve population variety for converging at global optimum. It has advantage of using method extract curves image other than parametric method, which Hough Transform (HT) can conclude. extracted by verified...

10.1117/12.754076 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2007-11-15
Coming Soon ...