R. Enríquez

ORCID: 0000-0001-5753-9363
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Building Energy and Comfort Optimization
  • Wind and Air Flow Studies
  • Astrophysics and Cosmic Phenomena
  • Urban Heat Island Mitigation
  • Solar and Space Plasma Dynamics
  • Solar Radiation and Photovoltaics
  • Gamma-ray bursts and supernovae
  • Dark Matter and Cosmic Phenomena
  • Solar Thermal and Photovoltaic Systems
  • Radioactive Decay and Measurement Techniques
  • Fluid Dynamics and Turbulent Flows
  • Advanced Control Systems Optimization
  • Agricultural Innovations and Practices
  • Geology and Paleoclimatology Research
  • Solar Energy Systems and Technologies
  • Aerodynamics and Acoustics in Jet Flows
  • Primate Behavior and Ecology
  • Meteorological Phenomena and Simulations
  • Knowledge Societies in the 21st Century
  • Control Systems and Identification
  • Efficiency Analysis Using DEA
  • Energy Efficiency and Management
  • Sustainable Building Design and Assessment
  • Particle Detector Development and Performance
  • Parasite Biology and Host Interactions

University of the Philippines Diliman
2019

Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas
2012-2018

Universidad Complutense de Madrid
2002-2017

IMDEA Energy Institute
2017

Universidad Autónoma del Estado de México
2009

Universidad Nacional Autónoma de México
1983-1989

Abstract The aim of this study was to determine the ornamental fish species affected by metacercariae digenean trematode Centrocestus formosanus and its distribution in 48 farms Morelos, central Mexico. parasite found form various numbers branchial cysts 11 25 analyzed. Goldfish Carassius auratus most commonly species; 20 30 were positive for parasite, showing severe clinical signs having a high mortality rate. For first time region, koi (a variant common carp Cyprinus carpio), zebrafish...

10.1577/h07-022.1 article EN Journal of Aquatic Animal Health 2009-03-01

In this paper we present a theoretical study of small solar chimney. The dimensions the chimney channel are 1.95 m high, 1.70 wide, and 0.24 deep. has in its backside metallic plate as heat absorber, it is attached to concrete wall, which acts storage thermal insulation. On front part glass cover used decrease losses exterior. For study, steady-state energy balance equations were solved numerically for each element results showed temperature profiles cover, air inside channel, plate. Also,...

10.1115/1.4007088 article EN Journal of Solar Energy Engineering 2012-08-09

In recent years, opaque ventilated facades have been widely used as passive constructive elements, specially in warm climate areas. Considering their increasing relevance, the present article focuses on study of thermal and energy behaviour open joint façades (OJVF). The fluid flow has carried out by application 2D Particle Image Velocimetry (PIV) techniques to a facade model designed for laboratory measurements. this work, instantaneous time averaged velocity fields along cavity obtained...

10.1016/j.egypro.2012.11.134 article EN Energy Procedia 2012-01-01

This paper develops a method, based on the PASCOOL methodology, to evaluate empirically climatic representativeness of two Spanish locations in different meteorological zones: semi-arid and Mediterranean climates. New Typical Meteorological Years (TMYs) have been created using 10 years measurement principal variables. Different weighting factors for computed variables considered. The selected TMYs obtained minimizing standard deviation with reference databases studied considering final use...

10.1016/j.egypro.2017.07.415 article EN Energy Procedia 2017-09-01

This paper focuses on the thermal comparison between two full-size occupied buildings located in Madrid, built considering different constructive criteria. Hourly temperature distributions have been calculated during working timetable to assess indoor dynamic processes. In both cases there are less than 4% of outliers, reaching lower standard deviations bioclimatic offices. Temperature oscillations shown profiles depending user's behavior. High percentages neutral sensation and low values...

10.1016/j.egypro.2017.07.413 article EN Energy Procedia 2017-09-01

Model Predictive Control (MPC) is a key issue to deal with Net Zero Energy Buildings (NZEBs) and Communities. The application of an MPC scheme in buildings requires accurate building model weather forecast. How needs be forecast common question for applications. In this work comfort tracking problem solved through receding horizon Scheme. To take into account both solar gains thermal inertia second order state space assumed generic building. Scheme applied Almería's climate (South Spain)to...

10.1016/j.egypro.2016.06.271 article EN Energy Procedia 2016-06-01

Prior to construction, the simulation of thermal behaviour a building is mandatory in Spanish Building Technical Code. However, there are few post-occupancy studies for buildings use implying simulation. In this work, model developed at design stage Passive Solar fitted/calibrated from experimental measurements. work it also new methodology fitting context occupied buildings. A aspect link between and be fitted. This technique useful two ways. First, allows assessing relative impact priori...

10.1016/j.egypro.2012.11.068 article EN Energy Procedia 2012-01-01

High-dispersion time-resolved spectroscopy of the dwarf nova SS Cygni was obtained during two consecutive days at end an outburst. The emission lines present a double-peaked profile with peak-to-peak separation |$526 \pm 14\,\text{ km s}^{-1}.$| have complex structure which includes narrow asymmetric component coming from hot spot in accretion disc or chromosphere red dwarf. radial velocity analysis yields semi-amplitude values |$K_\text{em}=96 5\,\text{ s}^{-1}$| for wings Hγ and Hβ,...

10.1093/mnras/240.4.975 article EN Monthly Notices of the Royal Astronomical Society 1989-10-01

Abstract. Land Surface Temperature (LST) is one of the important factors in monitoring urban climate. Observing variations LST can provide a better understanding Urban Heat Islands (UHI) phenomenon. The aim this research to assess relationship between spatial and temporal distribution water consumption Zamboanga City for years 2016 2017. Data from city’s district were used compute per capita (PCWC) 49 barangays. Landsat 8 data with 30m resolution computed using inverse Plank function other...

10.5194/isprs-archives-xlii-4-w19-193-2019 article EN cc-by ˜The œinternational archives of the photogrammetry, remote sensing and spatial information sciences/International archives of the photogrammetry, remote sensing and spatial information sciences 2019-12-23

This paper reports the study of different aspects data based modelling, focusing on physical issues and considering a simplified case study. Different analysis approaches have been applied to several series recorded in test conditions. The results compared. effect solar radiation, relevance non- constant surface effects evaluated through an exploratory mono-dimensional analysis. Afterwards tri- dimensional has applied, estimate overall UA gA value building. robustness is studied comparing...

10.1016/j.egypro.2015.11.390 article EN Energy Procedia 2015-11-01

The USAF Test Pilot School (TPS) and the Air Force Research Laboratory (AFRL) have partnered with Lockheed Martin General Electric (GE) Global to execute first flight test using dual bimorph synthetic jet (DBSJ) actuators in order demonstrate effectiveness of active flow control technology. phase aeroelastic load (ALC) program demonstrated use small, electronically controlled DBSJ mitigate effects turbulent airflow. TPS flew three missions that were dedicated evaluating this technology a...

10.1109/aero.2006.1656021 article EN IEEE Aerospace Conference 2006-08-03

The ``Gamma Ray Astronomy at ALmeria'' (GRAAL) experiment uses 63 heliostat-mirrors with a total mirror area of ~ 2500 m2 from the CESA-1 field to collect Cherenkov light airshowers. detector is located in central solar tower and detects photon-induced showers an energy threshold 250 +- 110 GeV asymptotic effective detection about 15000 m2. Data sets taken period September 1999 - 2000 direction Crab pulsar were analysed for high gamma-ray emission. Evidence flux integral 2.2 0.4 (stat)...

10.48550/arxiv.astro-ph/0108092 preprint EN other-oa arXiv (Cornell University) 2001-01-01
Coming Soon ...