Jun Xie

ORCID: 0000-0001-6657-0880
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High voltage insulation and dielectric phenomena
  • Microfluidic and Capillary Electrophoresis Applications
  • Fiber-reinforced polymer composites
  • Dielectric materials and actuators
  • Advanced Sensor and Energy Harvesting Materials
  • Power Transformer Diagnostics and Insulation
  • Optical Coherence Tomography Applications
  • Advanced Fluorescence Microscopy Techniques
  • Surface Modification and Superhydrophobicity
  • Mass Spectrometry Techniques and Applications
  • Electrohydrodynamics and Fluid Dynamics
  • Analytical Chemistry and Chromatography
  • Innovative Microfluidic and Catalytic Techniques Innovation
  • Advanced MEMS and NEMS Technologies
  • Laser-Plasma Interactions and Diagnostics
  • Methane Hydrates and Related Phenomena
  • Non-Destructive Testing Techniques
  • Electrowetting and Microfluidic Technologies
  • Advanced Sensor and Control Systems
  • Analytical Chemistry and Sensors
  • Geophysical Methods and Applications
  • Silicone and Siloxane Chemistry
  • Thermal Analysis in Power Transmission
  • Fusion materials and technologies
  • Synthesis and properties of polymers

North China Electric Power University
2016-2025

Kunming Medical University
2024

Shandong University of Science and Technology
2015-2024

Waseda University
2024

Shanxi Medical University
2024

China Academy of Engineering Physics
2016-2024

China National Offshore Oil Corporation (China)
2021-2024

Hunan University
2023

Hunan Institute of Science and Technology
2023

Hunan City University
2023

A microfluidic chip that integrates all the fluidic components of a gradient liquid chromatography (LC) system is described. These chips were batch-fabricated on silicon wafer using photolithographic processes and with Parylene as main structural material. The fabricated includes three electrolysis-based electrochemical pumps, one for loading sample other two delivering solvent gradient; platinum electrodes current to pumps establishing electrospray potential; low-volume static mixer; column...

10.1021/ac0510888 article EN Analytical Chemistry 2005-10-07

An electrostatically actuated micro peristaltic pump is reported. The entirely surface micromachined using a multilayer parylene technology. Taking advantage of the technology, design enables pumped fluid to be isolated from electric field. Electrostatic actuation membrane both DC and AC voltages was demonstrated applied pumping based on 3-phase sequence. A maximum flow rate 1.7 nL min−1 an estimated pressure 1.6 kPa were achieved at 20 Hz phase frequency. dynamic analysis also performed...

10.1039/b403906h article EN Lab on a Chip 2004-01-01

Thermoelectric (TE) hydrogels, mimicking human skin, possessing temperature and strain sensing capabilities, are well-suited for human-machine interaction interfaces wearable devices. In this study, a TE hydrogel with high toughness responsiveness was created using the Hofmeister effect current effect, achieved through cross-linking of PVA/PAA/carboxymethyl cellulose triple networks. The facilitated by Na

10.1021/acssensors.4c01202 article EN ACS Sensors 2024-07-28

Within the context of microfluidic systems, it has been difficult to devise pumping systems that can deliver adequate flow rates at high pressure for applications such as HPLC. An on-chip electrochemical system based on electrolysis offers certain advantages over designs utilize electroosmotic driven fabricated and tested. The pump was both silicon glass substrates using photolithography. electrodes were formed from either platinum or gold, SU8, an epoxy-based photoresist, used form...

10.1021/ac035188u article EN Analytical Chemistry 2004-05-15

Abstract The flashover and dampness on the surface of epoxy resin (ER) composites are two critical factors leading to failure high voltage direct current (HVDC) insulating devices. Designing constructing a structure with hydrophobic performance is an effective way solve these problems. In this paper, we prepared fluorinated silica nanoparticles (F‐SiO 2 ) using combination dielectric barrier discharge (DBD) plasma 1H,1H,2H,2H‐Perfluorodecyltrimethoxysilane (FAS‐17). resulting...

10.1002/pc.27547 article EN Polymer Composites 2023-07-01

This paper presents lumped-parameter simulation of dynamic characteristics peristaltic micropumps. The pump consists three pumping cells connected in series, each which is equipped with a compliant diaphragm that electrostatically actuated sequence to mobilize the fluid. Diaphragm motion cell first represented by an effective spring subjected hydrodynamic and electrostatic forces. These representations are then used construct system-level model for entire pump, accounts both cell- pump-level...

10.1088/0960-1317/17/2/006 article EN Journal of Micromechanics and Microengineering 2006-12-22

Bismuth ferrite nano‐ and microcrystals were prepared by a facile molten salt technique in two kinds of molten‐salt‐based systems ( NaCl – KCl Na 2 SO 4 ). In the system, systematic study indicating effects process parameters (e.g., calcination temperature, holding time as well ratios) on bismuth formation mechanism structural characteristics is reported. The results show that almost pure phase BiFeO 3 powders with minimum impurity Bi Fe O 9 synthesized at temperatures 700°C–800°C, whereas...

10.1111/jace.12897 article EN Journal of the American Ceramic Society 2014-03-17

With the increasing demands for higher treatment efficiency, better effluent quality, and energy conservation in Urban Wastewater Treatment Plants (WWTPs), research has already been conducted to construct an optimized control system Anaerobic-Anoxic-Oxic (AAO) process using a data-driven approach. However, existing optimization systems AAO mainly focus on improving water quality reducing consumption, therefore they lack consideration stability of bioreactors. Meanwhile, safety is still...

10.3390/w15091779 article EN Water 2023-05-05

Coal mine gas control has always been the focus of coal mining enterprises. Curing seam prevention and disaster technology is a new type local management to achieve rapid excavation. The key lies in changing generation conditions hydrate so that it can solidify reduce pressure seam. This paper measured contact angle four kinds thermodynamic accelerators on body, HCFC-141b was screened as by combining their own physical chemical properties. SDS-R141b compounding system used investigate its...

10.1080/15567036.2024.2354933 article EN Energy Sources Part A Recovery Utilization and Environmental Effects 2024-05-17

This paper combines simulation and experiment to construct a transient field model for gas-solid composite insulation. Nonlinear gas conductivity, which is constructed by ion transport, with material intrinsic surface conduction explore the electrical properties of epoxy resin (EP) under step gradient conductivity (SGSC). SGSC controls maximum charge density at triple junction, reduces total charge, alleviates strength, homogenizes electric distribution, suppresses power losses caused...

10.1109/tdei.2024.3403535 article EN IEEE Transactions on Dielectrics and Electrical Insulation 2024-05-21

Abstract The combination of computer algorithms to diagnose clinical images has attracted more and attention. This research aims improve the efficiency gastric cancer (GC) diagnosis, so deep learning (DL) are tentatively used assist doctors in diagnosis cancer. In experiment, collected 3591 gastroscopic were divided into network training set experimental verification test set. lesion samples image all marked by many endoscopists with years experience. order effect, 5261 endoscopic obtained...

10.1111/exsy.12758 article EN Expert Systems 2021-08-18

An integrated surface-micromachined mass flow controller (MFC) that consists of an electrostatically actuated microvalve and a thermal sensor is presented here. With unique design utilizing multilayer Parylene process, the active are onto single chip to perform closed-loop control. Sensitivity 55 PV/(/spl mu/L/min) for airflow 12.2 pV/(nL/min) water. The valve with 10 kHz AC signal applied pressure 21 kPa can be sealed actuation voltage 200 V/sub peak/ (/spl plusmn/200 V). For control, both...

10.1109/memsys.2003.1189677 article EN 2003-10-08
Coming Soon ...