Si Tang

ORCID: 0000-0001-7790-4575
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Force Microscopy Techniques and Applications
  • Micro and Nano Robotics
  • Cellular Mechanics and Interactions
  • Near-Field Optical Microscopy
  • Electrocatalysts for Energy Conversion
  • Adhesion, Friction, and Surface Interactions
  • Microtubule and mitosis dynamics
  • Catalytic Processes in Materials Science
  • Spectroscopy and Laser Applications
  • Error Correcting Code Techniques
  • Integrated Circuits and Semiconductor Failure Analysis
  • Advanced Chemical Physics Studies
  • Ultrasound and Hyperthermia Applications
  • Surface Modification and Superhydrophobicity
  • Laser Design and Applications
  • Gas Sensing Nanomaterials and Sensors
  • Fluid Dynamics and Thin Films
  • Cellular Automata and Applications
  • Advanced Wireless Communication Techniques
  • Catalysis and Hydrodesulfurization Studies
  • Optical Coherence Tomography Applications
  • Spaceflight effects on biology
  • Advanced Measurement and Metrology Techniques
  • Optical measurement and interference techniques
  • Microfluidic and Bio-sensing Technologies

Shenyang Institute of Automation
2022-2025

University of Chinese Academy of Sciences
2022-2025

Chinese Academy of Sciences
2022-2025

Dalian Institute of Chemical Physics
1988-2006

Gastric cancer is one of the deadliest malignant tumors digestive tract, and its development metastasis are regulated by various factors. Some studies have shown that PSMD2 involved in regulating tumor microenvironment stiffness. However, exact mechanism unclear, effective means to quantify effect on gastric tissue hardness lacking. Herein, we revealed mechanical heterogeneity tissues patients using a large-scale AFM-based situ method. cryosections were probed this method under aqueous...

10.1021/acs.nanolett.4c06514 article EN Nano Letters 2025-02-27

The scanning laser Doppler vibrometer (SLDV) is an extremely valuable method for studying the dynamic properties of vibrating objects, such as those in industrial production, entomology research, and biomedical testing. traditional SLDV scans samples using inclined laser, which ignores three-dimensional (3-D) information sample, resulting a relatively complicated calculation process. In processes scientific measured target may have known 3-D regular surface. When structure with height moves...

10.1109/tim.2022.3225055 article EN IEEE Transactions on Instrumentation and Measurement 2022-11-28

After eons of evolution, biological systems have developed excellent actuating methodology in micro-nano scale, which inspired the design and development advanced microrobots. Cardiomyocytes received extensive attention following bio-syncretic robots terms its spontaneous contraction high energy efficiency. However, multipoint, high-precision synchronized, comprehensive acquisition axial motion parameters cardiomyocytes still constitutes major factor hindering quantitative control methods...

10.1109/tnano.2023.3295850 article EN IEEE Transactions on Nanotechnology 2023-01-01

The typical selective state-space model (SSM) of Mamba addresses several limitations Transformers, such as quadratic computational complexity with sequence length and significant inference-time memory requirements due to the key-value cache. However, growing size models continues pose training deployment challenges raises environmental concerns considerable energy consumption. In this work, we introduce Bi-Mamba, a scalable powerful 1-bit architecture designed for more efficient large...

10.48550/arxiv.2411.11843 preprint EN arXiv (Cornell University) 2024-11-18

Production of hydrogen azide was studied using NaN<sub>3</sub> and oleic acid as reactant. The HN<sub>3</sub> yield no less than 70% in all experiments the highest 92.6% were obtained. results show that preparation is feasible better those strong inorganic or stearic to safety efficiency. An online measurement suggested by means mass spectrometer with capillary sampling.

10.1117/12.739414 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2006-09-22

The diversity of functional applications atomic force microscopes is the key to development nanotechnology. However, single probe configuration traditional microscope restricts realization different application requirements for same target area a sample, and replacement working will lead loss area. Here, design, simulation, fabrication, unique dual-probe are presented, which consists pair parallel cantilevers with narrow gap U-shaped hinged base. Integrated Hinged Dual-Probe (IHDP) developed...

10.1063/5.0167354 article EN Review of Scientific Instruments 2023-12-01

Abstract Atomic force microscopy (AFM) has been adopted in both industry and academia for high‐fidelity, full‐profile topographic characterization. Typically, the tiny tip of cantilever limited traveling range scanner restrict AFM measurement to relatively flat samples (recommend 1 µm). The primary objective this work is address these limitations using a large‐range (measuring height &gt;10 µm) system consisting novel repairable high aspect ratio probe (HARP) with...

10.1002/smtd.202300235 article EN Small Methods 2023-04-19

Abstract Three kinds of catalysts are prepared by sputtering: the normally supported catalyst (Pt/TiO2), inversely (TiO2/Pt), and cosputtered catalyst.

10.1002/chin.198835027 article EN ChemInform 1988-08-30
Coming Soon ...