Yu Yamaguchi

ORCID: 0000-0001-9388-2687
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Calibration and Measurement Techniques
  • Advanced Sensor Technologies Research
  • Scientific Measurement and Uncertainty Evaluation
  • Infrared Target Detection Methodologies
  • Thermography and Photoacoustic Techniques
  • Radiative Heat Transfer Studies
  • Advanced Frequency and Time Standards
  • Thermal Radiation and Cooling Technologies
  • Chemical Thermodynamics and Molecular Structure
  • Atomic and Subatomic Physics Research
  • Optical Polarization and Ellipsometry
  • Advanced optical system design
  • Remote-Sensing Image Classification
  • Photonic and Optical Devices
  • Advanced Memory and Neural Computing
  • Geochemistry and Geologic Mapping
  • Rare-earth and actinide compounds
  • Optical Coatings and Gratings
  • Atmospheric Ozone and Climate
  • Optical and Acousto-Optic Technologies
  • Neuroscience and Neural Engineering
  • Advanced Condensed Matter Physics
  • Advanced Electrical Measurement Techniques
  • Spectroscopy and Laser Applications
  • Ocular and Laser Science Research

Tokyo University of Science
2022

National Institute of Advanced Industrial Science and Technology
2004-2019

The thermodynamic temperature of the point inflection melting transition Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 0.18 K 1597.39 0.13 respectively, freezing Cu 1357.80 0.08 where symbol represents 95% coverage. These results are best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. good agreement between institutes suggests that...

10.1098/rsta.2015.0044 article EN Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences 2016-02-23

The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature uncertainty values specified within the mise en pratique of definition kelvin. These investigated in a collaboration eleven national measurement institutes laboratories. Published results reported point-of-inflection melting curve extremely low uncertainties. However, to be considered it is necessary stipulate what phenomenon value has ascribed to;...

10.1088/1681-7575/aa6eeb article EN Metrologia 2017-04-24

The hyperspectral imager of the HISUI (Hyperspectral Imager Suite) project will be deployed and operated in International Space Station (ISS) Japanese Experiment Module-Exposed Facility (JEM-EF) FY2018. pre-launch calibration is conducted using a large integrating sphere traceable to SI, after launch, onboard carried out unit including lamp. vicarious over dry lake sites located both northern hemisphere southern hemisphere, we may also use automated facilities due effects orbital...

10.1109/igarss.2016.7729495 article EN 2016-07-01

The time difference between coordinated universal (UTC) and a hydrogen maser, which is master oscillator for the local realization of UTC at National Metrology Institute Japan (NMIJ), has been predicted by using one deep learning techniques called one-dimensional convolutional neural network (1D-CNN). Regarding prediction result obtained 1D-CNN, we have observed improvement in accuracy compared with that Kalman filter. Although more investigations are required to conclude 1D-CNN can work as...

10.1063/1.5088533 article EN Review of Scientific Instruments 2019-12-01

The next Japanese earth observing hyperspectral/multispectral imager mission, the HISUI (Hyper-spectral Imager SUIte) is currently underway. In order to guarantee hyperspectral images with a high spatial and wavelength resolution, it necessary evaluate difference of spectral sensitivities among detector devices arrayed twodimensionally correct misregistrations effect stray light. Since there are tens thousands detectors in two-dimensional-array sensor, they have be evaluated parallel,...

10.1117/12.2029115 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2013-10-24

In order to guarantee the observed data with high spatial and wavelength resolution of hyperspectral/multispectral imagers, it is necessary evaluate difference spectral sensitivity among detector devices arrayed twodimensionally correct misregistrations effect stray light. However, there are tens thousands detectors in hyperspectral so they have be evaluated parallel by special technique. Therefore, a light-source system which has radiance uniformity widely tunable wavelengthrange required...

10.1117/12.973678 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2012-11-19

Abstract We investigated the nanoionics-based neuromorphic function of Pt/Ti 0.96 Co 0.04 O 2− δ /Pt multilayers with a cross-point structure prepared by RF magnetron sputtering. This multilayer exhibits electro-ion mixed conduction and nonlinear current–voltage characteristic based on Schottky barrier between Pt Ti layers. When low electrical pulse 0.8 V was applied short interval time 14 s, current modulation corresponding to long-term memorization (LTM) observed, though response at long...

10.35848/1347-4065/ac4dba article EN Japanese Journal of Applied Physics 2022-01-21

Abstract This article describes a preliminary study verifying the applicability of dual-wavelength reflectance-ratio (DWR) method to emissivity-free radiation thermometry for electromagnetically levitated high-temperature liquid metals. To establish measurement technique, DWR was applied inductively heated solid spherical Cu and Ni samples. Regardless differences in sample emissivity values, temperature determined using agreed within 20 K with thermocouple. It found that temperatures...

10.1088/1361-6501/ac8ca3 article EN Measurement Science and Technology 2022-08-25

A new method to estimate the uncertainty due non-linearity is described on n = 3 scheme basis. The expression of mathematically derived applying random walk method. simple and requires only temperatures fixed points a relative value for each flux-doubling from measurement. We also present an example method, in which temperature measurement by radiation thermometer calculated basis

10.1063/1.4821401 article EN AIP conference proceedings 2013-01-01

The earth-observing hyperspectral imager, HISUI (Hyper-spectral Imager SUIte), which is currently under development, has a wide spectral range from 0.4 μm to 2.5 μm, and the radiance of copper point insufficient for sensor calibration in wavelength shorter than 0.55 μm. This contrast predecessor (ASTER), whose shortest band 0.56 To cover short range, we have developed large-aperture cells high-temperature fixed points (HTFPs) cobalt-carbon (Co-C, 1324 °C), platinum-carbon (Pt-C, 1738 °C)...

10.23919/sice.2017.8105490 article EN 2017-09-01

Applicability of the dual-wavelength reflectance-ratio (DWR) method to high-temperature spherical metals was investigated. Solid nickel, copper and platinum spheres were used as samples for establishing experimental setup procedure. The heated inductively their temperatures monitored with a thermocouple attached sample. Their radiances measured using pyrometer at two different wavelengths, 900 1350 nm. calculated by analyzing sample without reflection an auxiliary light source. obtained DWR...

10.23919/sice.2017.8105614 article EN 2017-09-01

A bilateral comparison of radiance temperature scale between the National Institute Metrology Thailand (NIMT) and Research Center for Calibration, Instrumentation - Indonesian Sciences (Puslit KIM-LIPI) was conducted with support from Japan (NMIJ). 0.9 μm radiation thermometer provided by NMIJ used as transfer device in this comparison. same wavelength belonging to KIM-LIPI hand carried compared at range 600 °C 1500 °C, after which NIMT be calibrated means method against NIMT's nominal...

10.1109/sice.2015.7285325 article EN 2015-07-01

In order to guarantee the observed data with high spatial and wavelength resolution of hyperspectral/multispectral imagers, it is necessary evaluate difference spectral sensitivity among detector devices arrayed two-dimensionally correct misregistrations effect stray light. However, there are tens thousands detectors in hyperspectral so they have be evaluated parallel by special technique. Therefore, a light-source system which has radiance uniformity widely tunable wavelength-range required...

10.1117/12.977264 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2012-11-09
Coming Soon ...