- Aortic aneurysm repair treatments
- Cardiac, Anesthesia and Surgical Outcomes
- Vascular Procedures and Complications
- Aortic Disease and Treatment Approaches
- Infectious Aortic and Vascular Conditions
- Trauma Management and Diagnosis
- Peripheral Artery Disease Management
- Renal and Vascular Pathologies
- Abdominal vascular conditions and treatments
- Intracranial Aneurysms: Treatment and Complications
- Cerebrovascular and Carotid Artery Diseases
- Cardiac Structural Anomalies and Repair
- Cardiac Arrest and Resuscitation
- Cardiac Valve Diseases and Treatments
- Pesticide and Herbicide Environmental Studies
- Insect Resistance and Genetics
- Lung Cancer Treatments and Mutations
- Sperm and Testicular Function
- Adrenal and Paraganglionic Tumors
- Aortic Thrombus and Embolism
- Muscle and Compartmental Disorders
- Peripheral Nerve Disorders
- Hemoglobinopathies and Related Disorders
- Acute Ischemic Stroke Management
- Pancreatic function and diabetes
Papageorgiou General Hospital
2011-2024
Aristotle University of Thessaloniki
2007-2024
University of Basel
2020
Telio (Norway)
2011-2012
George Eliot Hospital
2011
Hellenic Red Cross
1983
Red Cross Hospital
1983
To report a case in which persistent high-flow type II endoleak after endovascular aneurysm repair (EVAR) of leaking abdominal aortic (AAA) complicated by an aortocaval fistula was repaired with stent-graft the inferior vena cava (IVC).A 76-year-old man underwent emergent EVAR aortomonoiliac device to exclude 9-cm AAA. The 30-day computed tomography (CT) scan showed 2-mm sac expansion and arising from lumbar artery; outflow vessel (IVC) via that not depicted on non-contrast preoperative CT...
To evaluate the feasibility and efficacy of a specific aortomonoiliac endograft durability femorofemoral bypass for treatment abdominal aortic aneurysm (AAA).From 2002 to 2004, 39 high-risk (ASA III/IV) patients (36 men; median age 74 years, range 63-84) with AAA (n = 33) or common iliac artery 6) were treated an EndoFit crossover bypass. The contralateral axis was obstructed endoluminal occluder. Patients followed contrast-enhanced computed tomography at 1, 6, 12, 24 months.EndoFit AMI...
To evaluate the feasibility and efficacy of repairing isolated iliac artery aneurysms with short proximal necks (<10 mm) by implanting EndoFit stent-graft.Seven patients (6 men; median age 73 years, range 70-78) were diagnosed an common (CIA) aneurysm that featured a landing zone, complicating endovascular treatment. The diameter was 4.4 cm (range 3.5-7.0), neck length 7 mm 5-9).The treated using stent-graft, which can be deployed in zone. modified technique involves deployment graft...
Abstract Two pesticides, the insecticide imidacloprid and herbicide acetochlor, were evaluated for their insecticidal genotoxic effects in Drosophila melanogaster . Their assessed by calculating LC 50 values after acute or chronic exposure of larvae adults to different concentrations test compounds. After exposure, was 7.59 × 10 −5 M 1.43 −4 adults, it 2.67 6.09 respectively. On contrary, acetochlor showed no effect against either even at very high (8 −3 M). For evaluation properties two...
To demonstrate the successful percutaneous removal of a tiny needle fracture from heart with use guide wire magnet at its distal end and two snares through both femoral veins.We report rare case in apex right ventricle drug abuser after migration neck lumen internal jugular vein. The procedure approach this foreign body was extremely difficult dangerous due to location size.This technique for proven be effective safe patient, it provides good therapeutic option intracardiac bodies.
The aim of this study was to provide early-term evaluation, safety, and efficacy the novel CGuard (Inspire MD, Tel Aviv, Israel) micromesh self-expanding stent with embolic protection system (EPS) during carotid artery stenting (CAS) procedure.All patients who underwent CAS from January 2018 September 2020 in a tertiary center were prospectively evaluated. Primary endpoints included technical success perioperative neurological events (0-48 hours). Secondary endpoint rate neurologic, cardiac...
Spontaneous rupture of a common iliac artery aneurysm into the vein is rare phenomenon. We report case 68 year old man admitted with acute cardiac failure and massive pulmonary embolism as complication spontaneous ilio-iliac fistula, secondary to aneurysmal rupture. The was successfully excluded using an aorto-uni-iliac stent graft. No complications were noted at 9 months follow-up. Arteriovenous fistulae should be considered in patients aortic or aneurysms who develop symptoms venous...
To present a rare case of patient with 12-cm posttraumatic right subclavian artery aneurysm successfully treated aneurysmectomy and innominate-axillary bypass.A 54-year-old man presented to the emergency department due progressive dyspnea hoarseness voice. His medical record was unremarkable except that he had right-sided pneumothorax multiple rib fractures from car accident 16 years ago. A chest X-ray showed mass in upper lobe lung, hospitalized for further investigation. computed...
Atherosclerotic lesions of the thoracic aorta and particularly mobile mural thrombi constitute a rare but important source cerebral peripheral emboli. Conventional treatment such pathologies includes systematic anticoagulation therapy surgical thromboendarterectomy, with potential segmental replacement using synthetic grafts. We report successful covering aortic thrombus commercially available endograft (Endofit) in patient presented multiple The endovascular constitutes new alternative...