Khaled Bekhouche

ORCID: 0000-0002-2787-0968
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle Detector Development and Performance
  • CCD and CMOS Imaging Sensors
  • Silicon and Solar Cell Technologies
  • Advanced Semiconductor Detectors and Materials
  • Radiation Detection and Scintillator Technologies
  • Analog and Mixed-Signal Circuit Design
  • Nanowire Synthesis and Applications
  • Semiconductor materials and interfaces
  • Sensor Technology and Measurement Systems
  • Infrared Target Detection Methodologies
  • Particle physics theoretical and experimental studies
  • Integrated Circuits and Semiconductor Failure Analysis
  • Advanced Power Amplifier Design
  • Semiconductor materials and devices
  • Semiconductor Quantum Structures and Devices
  • solar cell performance optimization
  • Photovoltaic System Optimization Techniques
  • Dark Matter and Cosmic Phenomena
  • Non-Destructive Testing Techniques
  • Advanced Measurement and Detection Methods
  • Welding Techniques and Residual Stresses
  • Solar Thermal and Photovoltaic Systems
  • Radiation Effects in Electronics
  • Advanced Welding Techniques Analysis
  • Advancements in Semiconductor Devices and Circuit Design

University of Biskra
2006-2023

Lancaster University
2008-2010

Rutherford Appleton Laboratory
2007

A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It designed to measure composition and spectral characteristics radiation field experiment its surroundings. This study demonstrates that MPX can also be used as a self-sufficient luminosity monitoring system. The detectors collect data independently data-recording chain, thus they provide independent measurements bunch-integrated ATLAS/LHC luminosity. In particular, located close enough...

10.1109/tns.2015.2496316 article EN cc-by IEEE Transactions on Nuclear Science 2015-12-01

Results of detailed simulations the charge transfer inefficiency a prototype serial readout CCD chip are reported. The effect radiation damage on operating in particle detector at high frequency future accelerator is studied, specifically creation two electron trap levels, 0.17 eV and 0.44 below bottom conduction band. Good agreement found between using ISE-TCAD DESSIS program an analytical model for former level but not latter. Optimum operation predicted to be about 250 K where effects...

10.1109/tns.2007.903180 article EN IEEE Transactions on Nuclear Science 2007-08-01

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) vertex detector of International (ILC). CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating...

10.1088/1748-0221/3/05/p05007 article EN Journal of Instrumentation 2008-05-28

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) vertex detector of a future Collider. CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating...

10.1109/tns.2009.2020985 article EN IEEE Transactions on Nuclear Science 2009-06-01

The effective space charge density <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">N</i> <sub xmlns:xlink="http://www.w3.org/1999/xlink">eff</sub> is the average of carriers over depletion layer in a semiconductor diode and measured from capacitance-voltage curve extrapolated to full xmlns:xlink="http://www.w3.org/1999/xlink">V</i> xmlns:xlink="http://www.w3.org/1999/xlink">d</sub> . Full modeling has been performed for PIN diodes made materials...

10.1109/tdmr.2012.2234460 article EN IEEE Transactions on Device and Materials Reliability 2012-12-21

Class D audio amplifiers are used in the devices. Nowadays, they preferred due to their high power efficiency compared other classes such as: class A, B and AB. In this paper, a amplifier is designed. It uses MOSFETs switching mode, closed-loop with second order integrator, pulse width modulator low pass filter. The system simulated Orcad-PSpice software. Simulated results show good values of THD+N, SNR, PSRR Efficiency.

10.1109/ispa48434.2019.8966832 article EN 2019-11-01

Results of detailed simulations the charge transfer inefficiency a prototype CCD chip are reported. The effect radiation damage in particle detector operating at future accelerator is studied by examining two electron trap levels, 0.17 eV and 0.44 below bottom conduction band. Good agreement found between using ISE-TCAD DESSIS program an analytical model for level. Optimum operation predicted to be about 250 K where effects traps minimal which approximately independent readout frequency....

10.1109/nssmic.2006.356222 article EN IEEE Nuclear Science Symposium conference record 2006-01-01

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying shortlived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) vertex detector of International (ILC). CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating...

10.1109/nssmic.2007.4436600 article EN IEEE Nuclear Science Symposium conference record 2007-01-01

&lt;span&gt;In this work, we have designed and simulated a proposed architecture good performances single-ended class-D audio amplifier (CDA). The circuit is build using pulse-width modulation (PWM). We novel RC network as negative feedback loop attached to second-order integrator get free of high-frequency carrier ripples reach improved output accuracy, thus performance efficiency. This extremely reduces total harmonic distortion plus noise (THD+N). used passive butterworth filter. fulfills...

10.11591/ijeecs.v26.i2.pp707-713 article EN Indonesian Journal of Electrical Engineering and Computer Science 2022-05-01

Download This Paper Open PDF in Browser Add to My Library Share: Permalink Using these links will ensure access this page indefinitely Copy URL DOI

10.2139/ssrn.4777743 preprint EN 2024-01-01

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) vertex detector of a future Collider. CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating...

10.1109/tns.2009.2026648 article EN IEEE Transactions on Nuclear Science 2009-10-01

A luminosity determination based on thermal neutron counting with six MPX silicon pixel devices installed in the ATLAS cavern is presented. Recently, Collaboration published final √s=8 TeV results. This made possible to perform a detailed comparison and verify potential of as novel method for measurements supplement well-established presently used procedures. measurement unique network has advantage that neutrons, which pass devices, cannot result from activation processes material nearby....

10.1088/1748-0221/12/09/p09010 article EN cc-by Journal of Instrumentation 2017-09-11

Abstract The present work presents a SILVACO-Atlas numerical simulation to investigate the effect of tunnel junction position on performance In x Ga 1−x N double-junction solar cells under AM1.5 illumination. proposed cell is composed two PN sub-cells, an upper sub-cell in 0.1 0.9 and lower 0.4 0.6 for p-type 0.2 0.8 n-type, connected by N. offers remarkable open-circuit voltage value about 3.9 V good fill shape 93. A with small overall thickness can offer better transfer efficiency than...

10.1088/2631-8695/acf11a article EN Engineering Research Express 2023-08-16

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) vertex detector of a future Collider. CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating...

10.1109/nssmic.2008.4774902 article EN IEEE Nuclear Science Symposium conference record 2008-10-01

We have carried out a numerical simulation of the effect gold doping on electrical characteristics long silicon diodes exposed to neutron irradiation. The aim is investigate hardness irradiated diodes. reverse current voltage and capacitance doped undoped are calculated for different irradiation doses. leakage effective density extracted from these two respectively. evaluated evolution with It was found that less sensitive than ones. Thus appears stabilise properties conduction mechanism...

10.1088/1674-4926/36/1/014001 article EN Journal of Semiconductors 2015-01-01

A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It designed to measure composition and spectral characteristics radiation field experiment its surroundings. This study demonstrates that MPX can also be used as a self-sufficient luminosity monitoring system. The detectors collect data independently data-recording chain, thus they provide independent measurements bunch-integrated ATLAS/LHC luminosity. In particular, located close enough...

10.1109/nssmic.2015.7581870 article EN 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) 2015-10-01

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) Collaboration has developing Column-Parallel CCDs vertex detector of a future which can be read out many times faster than standard CCDs. most recent studies are devices designed to reduce both CCD's...

10.1109/tns.2010.2041672 article EN IEEE Transactions on Nuclear Science 2010-04-01

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) vertex detector of a future Collider. CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating...

10.1109/nssmic.2008.4774903 article EN IEEE Nuclear Science Symposium conference record 2008-10-01

Pulse width modulation and pulse density are deemed to be main techniques, even PDM could not emulate PWM, in terms of, basically, simplicity. bitstream is encoded through sigma-delta modulation. Since modulation, compared needs very high switching frequency more complicated materials compose circuits, it’s difficult design one. In this article we a low-power class-D audio amplifier circuit where the analog signal into (PDM) using first-order (ΣΔ) modulator. The designed built Orcad-PSpice...

10.52549/ijeei.v10i3.3872 article EN Indonesian Journal of Electrical Engineering and Informatics (IJEEI) 2022-09-10

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades.Their spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles.The Linear Collider Flavour Identification (LCFI) Collaboration has developing Column-Parallel CCDs vertex detector of a future which can be read out many times faster than standard CCDs.The most recent studies are devices designed to reduce both CCD's...

10.1142/9789814307529_0095 article EN Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications 2010-04-01

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their spatial resolution and thin sensitive layers make them an excellent tool for studying shortlived particles. The Linear Collider Flavour Identification (LCFI) Collaboration has developing Column-Parallel CCDs vertex detector of a future which can be read out many times faster than standard CCDs. most recent studies are devices designed to reduce both CCD's...

10.1109/nssmic.2009.5402404 article EN 2009-10-01

In the present study, I-V characteristic of Au/n-InP Schottky barrier diode (SBD) was simulated in temperature range 200-300 K using numerical simulator Atlas-Silvaco. By taking to account appropriate physical models and presence deep traps quasi-neutral region, simulation performed goal understand effect on series resistance curves intersection point. The obtained results clarified that is related depth region. addition, prove point shift toward higher bias with increasing value. Also...

10.1109/ccee.2018.8634513 article EN 2018-12-01
Coming Soon ...