- Dental Implant Techniques and Outcomes
- Dental materials and restorations
- Orthodontics and Dentofacial Orthopedics
- Dental Radiography and Imaging
- Dental Research and COVID-19
- Temporomandibular Joint Disorders
- Periodontal Regeneration and Treatments
- Bone Tissue Engineering Materials
- dental development and anomalies
- Dental Health and Care Utilization
- Dental Trauma and Treatments
- Dental Education, Practice, Research
- Cleft Lip and Palate Research
- Orthopaedic implants and arthroplasty
- Dental Erosion and Treatment
- Scientific and Engineering Research Topics
- Oral and Maxillofacial Pathology
- Medical and Biological Ozone Research
- Oral microbiology and periodontitis research
- Ethics and bioethics in healthcare
- Health and Medical Education
- COVID-19 diagnosis using AI
- Dental Anxiety and Anesthesia Techniques
- Osteomyelitis and Bone Disorders Research
- Additive Manufacturing and 3D Printing Technologies
University Hospital Carl Gustav Carus
2022-2025
TU Dresden
2022-2025
Kiel University
2014-2023
University of Lübeck
2020
University Hospital Schleswig-Holstein
2020
Poliklinik für Zahnärztliche Prothetik
2020
University of Freiburg
2011-2013
University Medical Center Freiburg
2013
This clinical study evaluated the long-term outcome and survival rate of all-ceramic cantilever resin-bonded fixed dental prostheses (RBFDPs) made zirconia-ceramic with a single-retainer design to replace missing incisors. In addition, whether reason for incisors has an influence on longevity RBFDPs was analyzed.One hundred eight zirconia ceramic were provided 87 patients. Seventy-five replaced maxillary 33 mandibular The restorations subsequently categorized into 3 groups according reasons...
It was the aim of this 24-mo randomized controlled clinical trial to investigate whether survival a single median implant placed in edentulous mandible retain complete denture is not compromised by immediate loading. Secondary outcomes were differences prosthetic complications between loading principles. Each 158 patients who received an randomly assigned group ( n = 81) or delayed 77). Recall visits performed 1 mo after placement (for only group) and 1, 4, 12, 24 Nine implants failed group,...
Deep subgingival defects at the abutment teeth for fixed dental prostheses (FDPs) are a common problem in prosthodontics. Surgical crown lengthening or orthodontic extrusion of have been recommended treatment options. However, disadvantages such as extended time, costs, surgical problems to be considered. Proximal box elevation has proposed an alternative, but microleakage studies lacking. The purpose this vitro study was investigate influence proximal (PBE) and conventional foundation...
Summary To investigate whether there are differences in patients’ denture satisfaction when an implant placed the midline of edentulous mandible is loaded either immediately or three months later, after second‐stage surgery. One hundred and fifty‐eight patients received a single mandible. After randomisation, it was placement ( N = 81, group A) submerged healing phase surgery 77, B). Patients’ aspects were assessed, using visual analogue scales VAS ), before treatment, one month during (only...
The scientific evidence concerning prosthodontic care for the shortened dental arch (SDA) is sparse. This randomized multicenter study aimed to compare two common treatment options: removable partial prostheses (RPDPs) molar replacement vs. no (SDA). One of hypotheses was that follow-up differs between patients with RPDPs and SDAs during 5-year period. Two hundred fifteen complete loss in one jaw were included study. Molars either replaced by or not according SDA concept. A mean number 4.2...
A single implant can be placed to retain an overdenture in the edentulous mandible. This study aimed at development of Oral Health-related Quality Life comparing immediate and delayed loading, i.e., loading after 3 months submerged healing.In a randomized controlled trial, 158 participants received mandibular midline. life was measured using summary score German 49-item Health Impact Profile baseline, one month placement (direct group) as well four loading.Mean scores baseline were...
This multicenter randomized controlled clinical trial was conducted to investigate whether the loading protocol of single dental implants placed in midline edentulous mandibles will influence implant survival or prosthetic maintenance.In total, 158 patients were randomly assigned either immediate group (n = 81) delayed 77). All loaded with an overdenture retained by a ball attachment.After 5 years, 102 attended follow-up investigation. Immediately mandible revealed statistically significant...
To investigate the chewing efficiency and oral health-related quality of life edentulous patients wearing complete dentures, successively supported by one, two, three implants in mandible.Thirteen (13) at least 50 years age received mandible. After a conventional submerged healing period, central implant was uncovered connected to denture base using stud attachment. Two months later, efficacy evaluated, two lateral were base. The retention element replaced short abutment with no connection...
To assess the long-term clinical outcome of posterior inlay-retained fixed dental prostheses (IRFDPs) with a modified design made from zirconia ceramic. In 30 patients thirty 3-unit IRFDPs were placed to replace 7 second premolars (4 in maxilla, 3 mandible), and 23 first molars (15 8 mandible). Preparations accomplished agreement general principles for ceramic inlay restorations short retainer-wing bevel preparation within enamel at buccal oral sides. The frameworks milled 3Y-TZP ceramic,...
Abstract Objectives The aim of this prospective pilot study was to evaluate the prosthodontic maintenance as well implant outcome single implant‐retained mandibular overdentures over an observation period 6 years. Methods Eleven edentulous patients received one in midline mandible. Denture bases were temporarily relined and 2 months later provided with a ball attachment for retention. Implant related parameters interventions assessed 4 weeks after loading then once year. Results Over mean...
Over the years, there has been a strong consensus in dentistry that at least two implants are required to retain complete mandibular denture. It shown several clinical trials one single median implant can overdenture sufficiently well for up 5 years without failures, when delayed loading was used. However, other have reported conflicting results with part considerable failure rates immediate applied. Therefore it is purpose of current randomized trial test hypothesis midline an will result...