Sheng Bao

ORCID: 0000-0002-4574-1377
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Electron and X-Ray Spectroscopy Techniques
  • Advanced Chemical Physics Studies
  • X-ray Spectroscopy and Fluorescence Analysis
  • Radiation Shielding Materials Analysis
  • X-ray Diffraction in Crystallography
  • Surface and Thin Film Phenomena
  • Adhesion, Friction, and Surface Interactions
  • Surface Modification and Superhydrophobicity
  • Catalytic Processes in Materials Science
  • Magnetic properties of thin films
  • Fluid Dynamics and Heat Transfer
  • Video Surveillance and Tracking Methods
  • Crystallography and Radiation Phenomena
  • Radioactivity and Radon Measurements
  • Metamaterials and Metasurfaces Applications
  • 3D IC and TSV technologies
  • Advancements in Photolithography Techniques
  • Geophysical Methods and Applications
  • Advanced Antenna and Metasurface Technologies
  • Ga2O3 and related materials
  • High Altitude and Hypoxia
  • Heme Oxygenase-1 and Carbon Monoxide
  • Robotics and Sensor-Based Localization
  • nanoparticles nucleation surface interactions
  • Robotics and Automated Systems

Changchun University of Science and Technology
2022

Shanghai University
2021

Northwestern Polytechnical University
2014-2020

University of Electronic Science and Technology of China
1997-2011

Fritz Haber Institute of the Max Planck Society
1994-2002

University of Warwick
1987

The contact angle, as a vital measured parameter of wettability material surface, has long been in dispute whether it is affected by gravity. Herein, we the advancing and receding angles on extremely low angle hysteresis surfaces under different gravities (1-8G) found that both them decrease with increase underlying mechanism revealed to be deformation liquid-vapor interface away from solid surface caused gradient distribution hydrostatic pressure. real not gravity cannot an optical method....

10.34133/2020/2640834 article EN cc-by Research 2020-01-01

The study of the secondary electron composition contrast imaging method have been developed with a conventional scanning microscope (SEM) equipped ultra-thin window energy dispersive X-ray spectrometer (EDS). On basis principle emission, has investigated, and ranges its application were also discussed. This was applied in microstructure studies on cathode materials TWT (traveling wave tube). results showed that, compared backscattered image, image could reveal well certain conditions....

10.4028/www.scientific.net/msf.689.255 article EN Materials science forum 2011-06-01

It is shown that the relationship between mass attenuation coefficients and incoherent scattering radiation not an inverse proportion but a power function over wide range of atomic numbers (e.g. 5B–40Zr H3BO3–KBr). The experimental results are in good agreement with this theoretical prediction. A new method recommended for matrix absorption correction x-ray fluorescence analysis using Rh Kα Compton peak intensity. has been experimentally proved to be correct superior traditional internal...

10.1002/(sici)1097-4539(199701)26:1<23::aid-xrs180>3.0.co;2-j article EN X-Ray Spectrometry 1997-01-01

A panoramic annular lens optical system is important in circumferential detection. However, a image (PAI) has severe tangential and radial distortion. This study proposes 3σ guideline-based method, which determines the unwrapping center point of PAI, prediction method based on design characteristics according to intrinsic distortion PAL correct, respectively, The proposed methods can ensure restoration ability simplify dependence experimental conditions. results confirm effectiveness thus...

10.1364/ao.467881 article EN Applied Optics 2022-12-13

Abstract. Uncertainty modelling is regarded as one of the core components in field urban navigation, that can affect performance indoor and outdoor location information acquisition, especially under obscured scenarios. Existing multi-source fusion-based seamless positioning algorithms are subjected to random highly dynamic human motion characteristics changeable observation errors caused by occlusions buildings scenes, which lead insufficient spatiotemporal correlation poor accuracy final...

10.5194/isprs-annals-x-4-2024-493-2024 article EN cc-by ISPRS annals of the photogrammetry, remote sensing and spatial information sciences 2024-10-18

It is demonstrated that the mass attenuation coefficient not linearly related to inverse intensity of continuous scattered radiation as assumed in scattering internal standard method. A power function relationship between absorption and scatter over more than a limited range matrix composition predicted theoretically supported by experimental results. As an example application method it was applied determination trace Sr geological samples. The accuracy this much better traditional technique...

10.1002/(sici)1097-4539(199809/10)27:5<332::aid-xrs271>3.0.co;2-p article EN X-Ray Spectrometry 1998-09-01

Aimed at crack die problem of micro-package, a series experiments on failure components were conducted by using optical microscope, scanning electron microscope (SEM), Fein focus X-ray, cross section and various chemical etched methods. The analysis technique cracked in microelement was presented detail, the cause these found finally. Wafer processing defect has proven to be contributing factor cracking die. Mechanical damage acted as stress riser from which may propagate. root this...

10.1149/1.3360633 article EN ECS Transactions 2010-03-09

The cabin hospitals used for COVID-19 victims have an infectious environment and thus require highly autonomous systems to provide various services.This article presents a multirobot architecture designed with special focus on the sensors by service robots.The robots' functions include disinfection, delivery, cleaning, temperature measurement, physical interaction, conversation assistance.The robots collaborate each other using multiple in large complicated scenes evolve together.The are...

10.18494/sam.2021.3235 article EN cc-by Sensors and Materials 2021-09-15

It is demonstrated that the mass attenuation coefficient not linearly related to inverse intensity of continuous scattered radiation as assumed in scattering internal standard method. A power function relationship between absorption and scatter over more than a limited range matrix composition predicted theoretically supported by experimental results. As an example application method it was applied determination trace Sr geological samples. The accuracy this much better traditional technique...

10.1002/(sici)1097-4539(199809/10)27:5<332::aid-xrs271>3.3.co;2-g article EN X-Ray Spectrometry 1998-09-01

It is shown that the relationship between mass attenuation coefficients and incoherent scattering radiation not an inverse proportion but a power function over wide range of atomic numbers (e.g. 5B–40Zr H3BO3–KBr). The experimental results are in good agreement with this theoretical prediction. A new method recommended for matrix absorption correction x-ray fluorescence analysis using Rh Kα Compton peak intensity. has been experimentally proved to be correct superior traditional internal...

10.1002/(sici)1097-4539(199701)26:1<23::aid-xrs180>3.3.co;2-a article EN X-Ray Spectrometry 1997-01-01
Coming Soon ...