Ahad Mahootchi

ORCID: 0000-0002-5217-7866
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Glaucoma and retinal disorders
  • Corneal surgery and disorders
  • Ophthalmology and Eye Disorders
  • Retinal Diseases and Treatments
  • Laser Applications in Dentistry and Medicine
  • Retinal and Macular Surgery
  • Intraocular Surgery and Lenses
  • Corneal Surgery and Treatments
  • Ocular Disorders and Treatments
  • Pancreatitis Pathology and Treatment
  • Ophthalmology and Visual Impairment Studies
  • Abdominal Trauma and Injuries
  • COVID-19 and healthcare impacts
  • Proteoglycans and glycosaminoglycans research

The purpose of the study is to describe short-term efficacy and safety goniotomy with trabecular meshwork excision using Kahook Dual Blade (KDB, New World Medical Inc., Rancho Cucamonga, CA) in patients severe or refractory glaucoma.Retrospective multicentric case series 53 eyes glaucoma as defined by ICD-10 conducted United States, Mexico, Switzerland. Primary outcome was a ≥20% decrease intraocular pressure (IOP) from baseline at 6 months. Secondary measures were probability achieving an...

10.1097/ijg.0000000000001019 article EN Journal of Glaucoma 2018-07-04

To characterize the reduction in intraocular pressure (IOP) and IOP-lowering medication use following goniotomy via trabecular meshwork excision performed using Kahook Dual Blade as a stand-alone procedure adult eyes with glaucoma uncontrolled on regimen of 1–3 topical medications. In this retrospective analysis, data from consecutive patients undergoing by 11 surgeons were analyzed. Preoperative, intraoperative, postoperative follow-up through 6 months collected. The primary efficacy...

10.1007/s12325-018-0803-0 article EN cc-by-nc Advances in Therapy 2018-10-13

Purpose: To describe 12-month intraocular pressure (IOP) and medication use outcomes following excisional goniotomy (EG) as a stand-alone procedure in eyes with medically uncontrolled glaucoma. Methods: This was retrospective analysis of data from surgeons at 8 centers (6 US, 2 Mexico). Eyes glaucoma undergoing standalone EG specialized instrument (Kahook Dual Blade, New World Medical, Rancho Cucamonga, CA) for IOP reduction followed 12 months postoperatively were included. Data collected...

10.2147/opth.s256423 article EN cc-by-nc Clinical ophthalmology 2020-07-01

<P>Hypotonous maculopathy is a serious complication of glaucoma filtration surgery. A patient with hypotonous due to excessive was treated intravitreal gas. During the next several months, intraocular pressure increased and visual acuity improved. Intravitreal gas useful for treatment aqueous filtration. [<CITE>Ophthalmic Surg Lasers Imaging</CITE> 2006;37:234-235.]</P> <H4>AUTHORS</H4> <P>From Central Florida Retina Institute, Lakeland, (SMF);...

10.3928/15428877-20060501-09 article EN Ophthalmic surgery, lasers & imaging retina 2006-01-01
Coming Soon ...