- Dental materials and restorations
- Endodontics and Root Canal Treatments
- Dental Research and COVID-19
- Dental Erosion and Treatment
- Dental Implant Techniques and Outcomes
- Dental Anxiety and Anesthesia Techniques
- Dental Trauma and Treatments
- Dental Radiography and Imaging
- Dental Health and Care Utilization
- Oral microbiology and periodontitis research
- Laser Applications in Dentistry and Medicine
- Forensic Toxicology and Drug Analysis
- Medical Device Sterilization and Disinfection
- Additive Manufacturing and 3D Printing Technologies
- Orthodontics and Dentofacial Orthopedics
- Bone and Dental Protein Studies
- Infrared Thermography in Medicine
- Additive Manufacturing Materials and Processes
- Drug-Induced Adverse Reactions
- Nutritional Studies and Diet
- Scientific and Engineering Research Topics
- Concrete Corrosion and Durability
- Building materials and conservation
- Tattoo and Body Piercing Complications
- Analytical Chemistry and Sensors
Kırıkkale University
2011-2015
Selçuk University
2002-2010
Konya Food and Agriculture University
2009
summary The aim of this study was to compare the long‐term effectiveness five desensitizing products on 25 male and 27 female patients (total 52) aged 21–67 years (mean 36 ± 7 years) suffering from cervical dentine sensitivity. All subjects were seen by same examiner (ID) who blinded applied treatment for 3‐month clinical study. Patients asked record their overall sensitivity marking a point 10 cm Visual Analogue Scale (VAS). Two hundred seventy‐seven sensitive teeth treated one products,...
Abstract – The aim of the study was to investigate effect a new fiber‐reinforced composite restoration technique on fracture resistance in endodontically treated premolars. Eighty sound extracted human mandibular premolars were assigned four groups ( n = 20). Group 1 did not receive any treatment. In 2, 3 and 4, teeth received root canal treatment mesio‐occluso‐distal cavity preparation. 2 kept unrestored. restored with dentin bonding system resin. group piece polyethylene ribbon fiber...
The aim of this study was to evaluate the effects five self-etch dental composite resin cements on cell viability bovine papilla-derived cells.The cytotoxicity (Rely X Unicem Clicker, 3M ESPE; MaxCem; KERR, Panavia F 2.0; Kuraray, BisCem; Bisco and Bistite II DC; Tokuyama) analyzed in a dentin barrier test device using three-dimensional (3D) pulp cultures. A commercially available culture perfusion chamber separated into two compartments by 500 mum disc. three dimensional cultures placed...
Abstract This in vitro study was performed to compare the microtensile bond strengths (MTBS) of current self‐etching adhesives dentin and evaluate effects artificial aging [(thermocycling (TC) and/or mechanic loading (ML)] on MTBS nanoleakage adhesives. Two‐step (AdheSE Bond, Clearfil Protect SE Optibond Self‐Etch) one‐step (Hybrid G‐bond, Tri‐S Adper Prompt L‐Pop) were tested. Resin composite build‐ups created, specimens subjected 10 4 TC, 5 ML, /10 TC/ML. Non‐aged served as controls. In...
summary This study investigated the shear bond strengths of sectioned human mandibular incisor edge fragments reattached using luting cements, bonding agents or restored with composite resins. Seventy teeth were randomly distributed among six experimental groups and a control group. Leaving half anatomic crowns exposed, embedded in self‐cure acrylic resins exposed part then sectioned. The 1–4 bonded to their respective Clearfil Liner Bond 2V, Scotch Multi Purpose Plus, Panavia‐F 3M Opal...
To evaluate the cytotoxic effects of five different light-cured orthodontic bonding composites.The composites Heliosit Orthodontic (Ivoclar), Transbond XT (3M Unitek), Bisco ORTHO (Bisco), Light Bond (Reliance), and Quick Cure (Reliance) were prepared, samples extracted in 3 mL BME (Basal Medium Eagle) with 10% newborn calf serum for 24 hours. The L929 cells plated (25,000 cells/mL) a 96-well dish maintained humidified incubator hours at 37 degrees C, 5% CO(2), 95% air. After incubation...
The purpose of this study was to evaluate the influence a xylitol lozenge on dental plaque pH profile fixed orthodontic patients. Twelve volunteers participated in study. Before measurement pH, subjects were asked refrain from brushing their teeth for 48 hours and eating drinking two hours. subjects' baseline recorded using touch technique. It followed by one-minute rinse with 15 ml 10% solution sucrose, subsequent measurements carried out during next one hour. Xylitol lozenges taken five...
The purpose of this study was to determine whether the application two antibacterial mouth rinses etched and unetched enamel affects shear bond strength (SBS) an orthodontic composite resin. Eighty-five lower human incisors were divided into five groups, ie, group 1: control group, no rinse used; groups 2 3: applied intact surface before etching; 4 5: enamel. A bonding agent a resin teeth surface. For testing, specimens mounted in universal testing machine, apparatus attached compression...
As bond strength of currently available adhesive systems in caries-affected teeth dentin on primary tooth was not well known, the two bonding (PQI and OptiBond Solo Plus) evaluated sound molar observed micromorphology adhesive-dentin interfaces.By grinding both (n = 30) approximal surfaces teeth, flat were obtained. The prepared bonded with one each a composite resin. After storing specimens water at 37 degrees C for 24 h, samples sectioned tested by microshear test method. data...
Summary Five current dentin adhesives were evaluated for their ability to bond caries‐affected dentin. The materials were: total etch [Solid Bond (SB)], two self‐etch [Clearfil SE (CSE), Etch and Prime (EP)], one bottle [Prime 2·1 (PB), One Coat (OCB)]. Sixty extracted molar teeth with proximal caries (mesial or distal) extending into mid‐dentin used. By grinding normal surfaces, flat surfaces obtained. then bonded each adhesive system composite resins added the by packing material a...
summary This study was aimed at investigating the internal adaptation of a ceramic (Ceramco II) and two composite resin inlay materials (SureFil 3M Filtek Z 250 TM ) using silicon replica technique as an indicator. Forty‐five standard mesial–occlusal–distal (MOD) cavities were prepared into brass moulds by computer numerically controlled system. Inlays according to manufacturers’ instructions with indirect methods. Replicas inlays produced polyvinyl siloxane material (Elite H‐D). The spaces...
The aim of the present study was to determine whether application different primers containing antibacterial agents (Micro Prime™, Seal&Protect™, and Gluma Desensitizer™) can affect shear bond strength (SBS) an orthodontic resin composite.
The aim of this study was to determine the effect three storage solutions and two durations on microshear bond strength (microSBS) a resin composite. Sixty non-carious human permanent molars were stored in (0.1% thymol, 10% formalin, distilled water). Each tooth separated mesio-distally into parts. Specimens first part for 24 hours, while specimens second months solutions. After each period, enamel surface covered with composite combination an etch-rinse adhesive system. then serially...
To determine the cytotoxicity of three commercial mouthrinses Klorhex, Andorex and Tanflex on buccal epithelial cells using micronucleus (MN) test.
The aim of this study was to test the hypothesis that bonding ability antibacterial system primary dentin not different from parental material which did contain any component.Extracted human non-carious molars were ground expose coronal dentin, and then randomly divided into two experimental groups: treatment with Clearfil Protect Bond or SE (Kuraray Medical Inc.). Composite-dentin sticks a cross-sectional area approximately 0.90 mm(2) prepared subsequently subjected microtensile bond...
To evaluate the cytotoxic effects of three different resin-modified orthodontic band adhesives.Three adhesives (Bisco Ortho Band Paste LC, Multi-Cure Glass Ionomer Cement, and Transbond Plus Light Cure Adhesive) were prepared samples extracted in 3 mL Basal Medium Eagle with 10% newborn calf serum for 24 hours. The L929 cells plated (25,000 cells/mL) wells 96-well dishes maintained a humidified incubator hours at 37 degrees C, 5% CO(2), 95% air. After 24-hour incubation cells, medium was...
To evaluate the cytotoxicity of resin cements on dental pulp-derived cells (bDPCs), Bifix QM (BQM), Choice 2(C2), RelyX U200(RU200), Maxcem Elite(ME), and Multilink Automix(MA) were tested. The materials incubated in DMEM for 72 h. A real-time cell analyzer was used to survival. statistical analyses one-way ANOVA Tukey-Kramer tests. BQM, RU200, ME demonstrated a significant decrease bDPCs' index at 24 h (p≤0.001). These found be most toxic cements, as compared control other tested (C2 MA)....