Marjan Miletić

ORCID: 0000-0002-8476-4141
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • ECG Monitoring and Analysis
  • Non-Invasive Vital Sign Monitoring
  • EEG and Brain-Computer Interfaces
  • Cardiac Imaging and Diagnostics
  • Cardiac electrophysiology and arrhythmias
  • Phonocardiography and Auscultation Techniques
  • Respiratory Support and Mechanisms
  • Muscle activation and electromyography studies
  • Hemodynamic Monitoring and Therapy
  • Musculoskeletal pain and rehabilitation
  • Advanced Fiber Laser Technologies
  • Cardiac Arrhythmias and Treatments
  • Vehicle Noise and Vibration Control
  • Atomic and Subatomic Physics Research
  • Analog and Mixed-Signal Circuit Design
  • Advanced Sensor and Energy Harvesting Materials
  • Photonic Crystals and Applications
  • Nonlinear Photonic Systems
  • Cardiovascular Health and Disease Prevention
  • Thyroid Disorders and Treatments
  • Advanced Fiber Optic Sensors

RadiaBeam Technologies (United States)
2023-2024

Academy of Engineering Sciences of Serbia
2024

University of Belgrade
2015-2024

Vinča Institute of Nuclear Sciences
2020-2024

Walsh University
2023-2024

Institute of Economic Sciences
2020

University of Novi Sad
2015

<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Goal:</i> Clinical interpretation of an electrocardiogram (ECG) can be detrimentally affected by noise. Removal the electromyographic (EMG) noise is particularly challenging due to its spectral overlap with QRS complex. The existing EMG-denoising algorithms often distort signal morphology, thus obscuring diagnostically relevant information. xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</i>...

10.1109/ojemb.2024.3380352 article EN cc-by-nc-nd IEEE Open Journal of Engineering in Medicine and Biology 2024-01-01

Early coronary occlusion detection by portable personal device with limited number of electrocardiographic (ECG) leads might shorten symptom-to-balloon time in acute syndromes. The purpose this study was to compare the accuracy using vectorcardgiographic analysis a near-orthogonal 3-lead ECG configuration suitable for credit card-size integration automated and human 12 lead interpretation. 12-lead ECGs 3 additional ("abc") 2 arm left parasternal electrodes were recorded 66 patients...

10.1016/j.jacadv.2023.100454 article EN cc-by JACC Advances 2023-07-27

Abstract Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are utmost interest a non-stressed life. WSM which records heart muscle activities could signalize timely life-threatening event. The typically recorded across at surface body; hence, monitor requires high-quality electrodes. electrodes used in clinical settings [i.e. silver/silver chloride (Ag/AgCl) with gel] not practical daily out clinic usage. A application dry electrode stable and...

10.1515/bmt-2019-0167 article EN Biomedical Engineering / Biomedizinische Technik 2020-04-01

Non-invasive ventilation performed through an oronasal mask is a standard in clinical and homecare mechanical ventilation. Besides all its advantages, inevitable leaks the cause errors feedback information provided by airflow sensor and, hence, patient-ventilator asynchrony with multiple negative consequences. Here we investigate new way to provide trigger ventilator. The method based on measurement of rib cage movement at onset inspiration during breathing fibre-optic sensors. In series...

10.1109/embc.2015.7319397 article EN 2015-08-01

Clinical outcomes of several acute conditions, including myocardial infarction (MI), the most common cause death, can be improved by timely diagnostics based on electrocardiography (ECG). However, current diagnostic technologies include a large number wired ECG electrodes, which require accurate placement trained personnel. The ideal device would suitable for self-measurement, i.e., have small mobile or portable, and provide an diagnosis. these aims not been met using same device. A recently...

10.1109/access.2024.3408412 article EN cc-by-nc-nd IEEE Access 2024-01-01

ECG measurements at rest are susceptible to different kinds of noise which may affect clinical interpretation. Unlike the low-frequency body movements or spectrally well-defined power line interference, broadband electromyographic (EMG) coincides with QRS complex, makes its removal particularly challenging. While a number algorithms have been developed, their evaluation and comparison long remained challenging due lack database EMG-contaminated genuine noise-free signals. We recently...

10.69994/11ic24007 article EN 2024-07-31

Introduction: Early prehospital chest pain assessment improves acute coronary syndrome (ACS) outcomes and can reduce unnecessary Emergency Room (ER) visits but requires medical personnel electrocardiographic (ECG) equipment. Objective: To evaluate the feasibility of a personal credit-card sized self-assessment device (HeartBeam, Santa Clara, CA, USA) in diagnosing ACS. Methods: ACS risk was estimated by serial likelihood ratio analysis 3 components: pre-existing heart disease (CHD)...

10.1161/circ.150.suppl_1.4120657 article EN Circulation 2024-11-12

Background: The multiple electrodes needed to generate a 12-lead electrocardiogram (12L ECG) limits its use traditional health care settings. An innovative credit-card sized unit (HeartBeam, Santa Clara, CA, USA) when placed on the chest without cables captures vectorcardiogram (VCG). A personalized transformation matrix (PTM) then converts signals into 12L ECG. Objective: This is first quantitative (standard intervals and amplitudes) qualitative (rhythm diagnosis) accuracy assessment of...

10.1161/circ.150.suppl_1.4141704 article EN Circulation 2024-11-12

Acute myocardial infraction (AMI) is a leading cause of death in the developed countries. Survival patients having acute coronary syndrome (ACS) dramatically depends on treatment delay. Hence, technology that would enable ECG recording immediately after ACS symptom occurrence may significantly decrease AMI mortality. In this study we investigate signal quality reconstructed 12-lead ECGs by using 3-lead handheld device with dry electrode realistic ambulatory conditions. For each subject...

10.1109/embc.2019.8857251 article EN 2019-07-01

<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Goal:</i> Noise on recorded electrocardiographic (ECG) signals may affect their clinical interpretation. Electromyographic (EMG) noise spectrally coincides with the QRS complex, which makes its removal particularly challenging. The problem of evaluating noise-removal techniques has commonly been approached by algorithm testing contaminated ECG constructed...

10.1109/ojemb.2023.3330295 article EN cc-by-nc-nd IEEE Open Journal of Engineering in Medicine and Biology 2023-01-01

Objective: The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask.The interface of the mask with patient promotes air leaks that cause errors feedback information provided by pneumatic sensor and hence patient-ventilator asynchrony multiple negative consequences.Our objective is to test possibility using chest-wall motion measured an optical fibre-grating as more accurate triggering mechanism. Approach:The basic premise our approach...

10.1088/1361-6579/aab7ac article EN Physiological Measurement 2018-03-19

Disturbances of thyroid function are often accompanied by cognitive and affective disorders. Assessment status in the patients with subclinical hypothyroidism represents a possibility for early diagnostics impairment timely introduction necessary pharmacotherapy treatment. The aim this study was to quantify whether there P3 event related potential (ERP) deviations as electrophysiological markers activity hypothyroidism. P300 potentials were examined thirty 30 healthy subjects control group....

10.5937/pramed1502097d article EN cc-by Praxis medica 2015-01-01

We report the preliminary results of a laboratory validation study new polycardiographic device for assessment cardiovascular function (SensSmartTech). The main principle behind polycardiography is synchronized measurement multiple electro- mechanical parameters system. non-invasive and entails electrocardiography, photoplethysmography, phonography seismography. study’s validate use proposed policardiograph implementation in settings with varying physiological conditions both clinical...

10.46793/iccbi23.043l article EN 2023-01-01
Coming Soon ...