Maximilian Treder

ORCID: 0000-0002-8533-6026
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Retinal Imaging and Analysis
  • Retinal Diseases and Treatments
  • Glaucoma and retinal disorders
  • Optical Coherence Tomography Applications
  • Retinal and Macular Surgery
  • Retinal and Optic Conditions
  • Corneal surgery and disorders
  • AI in cancer detection
  • Corneal Surgery and Treatments
  • Retinal Development and Disorders
  • Intraocular Surgery and Lenses
  • Atrial Fibrillation Management and Outcomes
  • Allergic Rhinitis and Sensitization
  • Photoacoustic and Ultrasonic Imaging
  • Ophthalmology and Visual Impairment Studies
  • Heparin-Induced Thrombocytopenia and Thrombosis
  • Climate Change and Health Impacts
  • Entomological Studies and Ecology
  • Air Quality and Health Impacts
  • Vascular Malformations Diagnosis and Treatment
  • Innovative Teaching Methods
  • Biomedical Text Mining and Ontologies
  • Origins and Evolution of Life
  • Travel-related health issues
  • Optimism, Hope, and Well-being

Klinik und Poliklinik für Augenheilkunde Universitätsklinikum Regensburg
2020-2021

Ophthalmology Clinic
2017-2021

University Hospital Münster
2013-2021

University of Münster
2017-2019

Universitätsklinik für Augenheilkunde
2019

University of Birmingham
2016

Fraunhofer Institute for Production Systems and Design Technology
2011

Technische Universität Berlin
2011

Radboud University Nijmegen
2010

Purpose: To evaluate the effects of exercise on optic nerve and macular perfusion using optical coherence tomography angiography. Methods: Thirteen eyes 13 healthy volunteers were examined a high-speed high-resolution spectral-domain XR Avanti with split-spectrum amplitude-decorrelation angiography algorithm. Blood pressure, heart rate, mean area foveal avascular zone , flow density head macula, before after measured analyzed. Results: Mean patient age was 27.3 ± 3.5 years. Heart systolic...

10.1097/iae.0000000000001419 article EN Retina 2016-12-11

To evaluate a deep learning-based method to automatically detect graft detachment (GD) after Descemet membrane endothelial keratoplasty (DMEK) in anterior segment optical coherence tomography (AS-OCT).In this study, total of 1172 AS-OCT images (609: attached graft; 563: detached graft) were used train and test convolutional neural network GD DMEK surgery images. was defined as not completely graft. After training with 1072 these (559: 513: graft), the created classifier tested remaining 100...

10.1097/ico.0000000000001776 article EN Cornea 2018-10-05

Brain-computer interfaces based on event-related potentials face a trade-off between the speed and accuracy of system, as both depend number iterations. Increasing iterations leads to higher but reduces system. This is generally dealt with by finding fixed that give good result calibration data. We show here this method sub optimal increases performance significantly in only one out five datasets. Several alternative methods have been described literature, we test generalization four them....

10.1109/iembs.2011.6091134 article EN Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2011-08-01

<b><i>Purpose:</i></b> To evaluate choriocapillaris (CC) perfusion in healthy subjects using 2 different optical coherence tomography angiography (OCT-A) devices. <b><i>Procedures:</i></b> Macular OCT-A imaging (36 eyes of 36 subjects) was performed Optovue AngioVue and Zeiss AngioPlex CC decorrelation signal index assessed, data were analyzed regarding intra-device variability, inter-device correlation, age, strength, fields view....

10.1159/000464355 article EN Ophthalmologica 2017-01-01

Abstract Purpose The present retrospective study was designed to test the hypothesis that postoperative posterior preoperative anterior corneal curvature radii (PPPA) ratio in eyes with Fuch’s dystrophy undergoing Descemet membrane endothelial keratoplasty (DMEK) is significantly different (PA) virgin and therefore renders conventional keratometry (K) power derived by it invalid for intraocular lens (IOL) calculation. Methods Measurement of parameters performed using Scheimpflug imaging...

10.1007/s00417-020-04998-w article EN cc-by Graefe s Archive for Clinical and Experimental Ophthalmology 2020-11-13

To evaluate the utility of intraocular lens (IOL) power calculation using adjusted conventional keratometry (K) according to postoperative posterior preoperative anterior corneal curvature radii (PPPA) ratio for eyes with Fuch's dystrophy undergoing cataract surgery combined Descemet membrane endothelial keratoplasty (triple DMEK).A fictitious refractive index (FRI) was determined (Pentacam HR®) based on PPPA in 50 triple DMEK. Adjusted calculated every eye K values: values by IOLMaster were...

10.1007/s00417-022-05598-6 article EN cc-by Graefe s Archive for Clinical and Experimental Ophthalmology 2022-03-08

Zusammenfassung Hintergrund Die vorliegende Studie vergleicht die Ausprägung von Bewegungsartefakten bei Aufnahmen der optischen Kohärenztomografie-Angiografie (OCT-A) gesunden Probanden zwischen 2 OCT-A-Systemen verschiedener Hersteller mit unterschiedlicher technischer Ausstattung. Methodik In dieser Arbeit wurden 25 Augen (19 weiblich, mittleres Alter 31,12 ± 11,95 Jahre) ohne bestehende Augenerkrankungen oder zurückliegende Augenoperationen eingeschlossen. OCT-A-Aufnahmen dem RTVue XR...

10.1055/a-0838-5880 article DE Klinische Monatsblätter für Augenheilkunde 2019-04-02

The aim of this study was to use deep learning based on a convolutional neural network (DCNN) for automated image classification healthy optic discs (OD) and visible disc drusen (ODD) fundus autofluorescence (FAF) color photography (CFP). In study, total 400 FAF CFP images patients with ODD controls were used. A pre-trained multi-layer Deep Convolutional Neural Network trained validated independently images. Training validation accuracy cross-entropy recorded. Both generated DCNN classifiers...

10.3390/jcm12051951 article EN Journal of Clinical Medicine 2023-03-01

Abstract Slowing is a common feature of ageing, yet direct relationship between neural slowing and brain atrophy to be established in healthy humans. We combine magnetoencephalographic (MEG) measures processing speed with magnetic resonance imaging (MRI) white- gray-matter large (N=617, 18-88yrs), population-derived cohort ( www.cam-can.org ) investigate the age-related structural differences VEF AEF delay across two different tasks. Using novel technique, we show that VEFs exhibit constant...

10.1101/056440 preprint EN cc-by-nc-nd bioRxiv (Cold Spring Harbor Laboratory) 2016-06-01

To analyze the influence of a cilioretinal artery (CRA) on macular and peripapillary vessel density in healthy eyes as measured using optical coherence tomography angiography.A total 83 patients were included this study. Optical angiography was performed RTVue XR Avanti with AngioVue (Optovue Inc). The macula imaged 3 × 3-mm scan, whereas for optic nerve head 4.5 4.5-mm scan taken. images screened presence CRA.In 31 eyes, CRA detected (37.3%). significantly lower within (P = 0.005) but...

10.1097/iae.0000000000003208 article EN Retina 2021-05-14

Zusammenfassung Die altersabhängige Makuladegeneration (AMD) ist der führende Grund für Erblindung in westlichen Welt. Für die neovaskuläre Verlaufsform steht mit intravitrealen Anti-VEGF-Injektion (VEGF: vascular endothelial growth factor) eine wirksame Therapie zur Verfügung. In den letzten Jahren haben multimodale Bildgebung und standardisierte elektronische Patientendokumentation geholfen, Diagnostik das Management AMD-Patienten zu verbessern. Mit dem Aufkommen künstlichen Intelligenz...

10.1055/a-1012-2036 article DE Klinische Monatsblätter für Augenheilkunde 2019-10-31
Coming Soon ...