- Glaucoma and retinal disorders
- Corneal surgery and disorders
- Retinal Diseases and Treatments
- Ophthalmology and Visual Impairment Studies
- Ophthalmology and Eye Disorders
- Intraocular Surgery and Lenses
- Corneal Surgery and Treatments
- Retinal Imaging and Analysis
- Retinal and Macular Surgery
- Atrial Fibrillation Management and Outcomes
- Cerebrovascular and Carotid Artery Diseases
- Cellular Mechanics and Interactions
- Ocular Surface and Contact Lens
- Cardiovascular Health and Disease Prevention
- Vehicle emissions and performance
- Migraine and Headache Studies
- melanin and skin pigmentation
- Traumatic Ocular and Foreign Body Injuries
- Nasolacrimal Duct Obstruction Treatments
- Optical Coherence Tomography Applications
- Heparin-Induced Thrombocytopenia and Thrombosis
- Retinal Development and Disorders
- Neurological Disorders and Treatments
- Retinopathy of Prematurity Studies
- Axon Guidance and Neuronal Signaling
Helios Universitätsklinikum Wuppertal
2018-2022
Witten/Herdecke University
2020-2022
Universitätsklinikum Würzburg
2017-2019
University of Würzburg
2016-2018
Augenklinik Universitätsklinikum Würzburg
2016-2018
Ophthalmology Clinic
2015-2018
University Hospital Münster
2015-2017
University of Münster
2015-2017
University of Cologne
2005-2015
Oculus Optikgeräte (Germany)
2015
Purpose: To evaluate the effects of exercise on optic nerve and macular perfusion using optical coherence tomography angiography. Methods: Thirteen eyes 13 healthy volunteers were examined a high-speed high-resolution spectral-domain XR Avanti with split-spectrum amplitude-decorrelation angiography algorithm. Blood pressure, heart rate, mean area foveal avascular zone , flow density head macula, before after measured analyzed. Results: Mean patient age was 27.3 ± 3.5 years. Heart systolic...
Purpose: The aim of the study was to quantify Scheimpflug corneal densitometry in patients with Fuchs endothelial dystrophy (FED). Methods: In this study, we retrospectively reviewed charts and anterior segment data 49 FED before posterior lamellar keratoplasty 51 healthy controls. were examined using Scheimpflug-based Oculus Pentacam. Central thickness (CCT), ring-averaged (on a circle 2, 2.4–10 mm diameter) noncentral thickness, different layers annuli extracted analyzed. Results: total...
The aim of this study was to determine the efficacy accelerated riboflavin-ultraviolet A-induced corneal collagen cross-linking (CXL) (irradiance 18 mW/cm² for 5 minutes).In study, we retrospectively reviewed charts and anterior segment data patients after CXL. Visual, topographic, pachymetry, densitometry were extracted analyzed before surgery at follow-up (minimum 12 months) treatment.A total 28 eyes 20 (mean age, 28.1 ± 8.1 years) included in study. mean time 21.7 7.2 months (range, 12-34...
To compare intraocular pressure (IOP) measurements obtained by rebound tonometry (Icare PRO tonometer), applanation (Goldmann and Perkins tonometry), dynamic contour in the upright supine positions, to investigate influence of axial length central corneal thickness.Ninety-nine right eyes 99 patients with glaucoma or suspect for glaucoma, admitted our department between November 2010 January 2011 obtain an IOP profile including measurements, were included study. position using Icare (RTPRO),...
To quantify changes in the refractive power of anterior and posterior corneal surfaces after Descemet membrane endothelial keratoplasty (DMEK) so as to optimize accuracy intraocular lens (IOL) calculations.This study included 28 eyes 21 patients (age 66.6 ± 9.4 years, 11 female, 10 male). Scheimpflug-based Oculus Pentacam imaging was performed before DMEK surgery for Fuchs dystrophy. Corneal measured using K-value simulated keratometry (SimK) total (TCRP) zones from 1 8 mm (SimK 1-8,...
Purpose: The aim of the study was to quantify corneal densitometry in patients with Fuchs endothelial dystrophy (FED) after keratoplasty.Materials and methods: We retrospectively reviewed charts anterior segment data FED before keratoplasty. Patients were examined using Scheimpflug-based Oculus Pentacam module. Densitometry parameters different layers annuli extracted analyzed.Results: 27 eyes keratoplasty (11 DSAEK, 16 DMEK) included. After total light backscatter at thickness central...
To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with newly available iCare HOME (RTHOME) rebound tonometer compared ONE (RTONE) and Goldmann applanation tonometry (GAT), possible correlation central corneal thickness (CCT).IOP were from 154 patients by an ophthalmologist (doc) using each above-mentioned tonometers. In addition, (pat) measured their own IOP RTHOME RTONE. The means SD results different tonometers compared. Agreement between was calculated...
PURPOSE: To determine long-term changes in corneal transparency after riboflavin-ultraviolet A-induced collagen cross-linking (CXL). METHODS: Charts and anterior segment data of patients CXL for progressive keratoconus were retrospectively reviewed. Patients examined using the Scheimpflug-based Pentacam densitometry module (Oculus Optikgeräte, Wetzlar, Germany) before at five postoperative follow-up visits: 1 to 3, 3 6, 6 12, 12 24, 24 36 months. RESULTS: Forty-two eyes 28 (mean age: 27.9 ±...
Abstract Coronin‐3 (coronin‐1C), a homotrimeric F‐actin binding protein, has been shown to be important for cell migration and brain morphogenesis. Here, we present the first time detailed analysis of expression pattern coronin‐3 in human tumours demonstrate that correlates with malignant phenotype diffuse gliomas. In general, varies different tumour entities. However, gliomas, number expressing cells degree malignancy. High‐grade such as anaplastic astrocytomas, oligodendrogliomas,...
<h3>Background</h3> Aqueous flare as determined by laser photometry in the anterior chamber is a strong preoperative predictor for proliferative vitreoretinopathy (PVR) patients with primary retinal detachment (RD). We analysed various cytokines aqueous humour samples relation to and postoperative PVR incidence RD. <h3>Methods</h3> Preoperatively, of RD was measured quantitatively metre were collected interferon γ, tumour necrosis factor α, monocyte chemoattractant protein (MCP)-1,...
To compare the practicability of using an Icare rebound tonometer (RT) versus a Goldmann applanation (GAT) or Pascal dynamic contour (DCT) for measuring intraocular pressure (IOP) in patients with corneal abnormalities and, furthermore, to study influence central thickness, diameter, radius, and axial length.One hundred seventy-one pathologic eyes 26 nonpathologic control 99 were included. Pathologic corneas divided into subgroups: previous keratoplasty, keratoconus, scars, dystrophies,...
<b><i>Purpose:</i></b> To assess the efficacy of trabeculectomy with a biodegradable Ologen™ implant (OLO) versus mitomycin C (MMC) in patients prospective randomized clinical trial. <b><i>Methods:</i></b> In MMC group (15 patients), was performed according to standard protocols. OLO patients) after trabeculectomy, positioned on top scleral flap, and no applied. <b><i>Results:</i></b> Mean preoperative intraocular...
To evaluate the effect of capsular tension ring (CTR) implantation on refractive outcomes in patients with high myopia.University Cologne, Department Ophthalmology, Germany.Comparative case series.The myopic eyes were compared between phacoemulsification and IOL a CTR (CTR group) without (control group). Optical biometry (IOLMaster) was obtained. The power used to calculate predicted postoperative spherical equivalent using Haigis SRK/T formulas. main outcome measures mean error absolute...
Optical coherence tomography angiography is a novel imaging technique that allows dyeless in vivo visualization of the retinal and choroidal vasculature. The purpose this study was to describe optical (OCT) findings patients with arterial macroaneurysms (RAMs). Three eyes three RAMs were retrospectively included. Fundus photography, OCT, fluorescein (FA), OCT performed. entire data analyzed detail. could detect noninvasively without dye injection. By simultaneously observing scans, it...
Purpose. This study aimed to evaluate long-term results of external dacryocystorhinostomy (DCR) at a tertiary eye care center specializing in lacrimal duct surgery Germany. Methods. The medical records 1010 patients with acquired nasolacrimal obstruction (NLDO), who had undergone center, were reviewed. Only adult DCR included. evaluation included the following parameters: age, gender, duration symptoms, patient satisfaction, previous dacryocystitis, complication rates, and surgical outcome....
To describe the long-term outcome of canthaxanthin retinopathy.We identified 13 patients with small golden particles near macular region among a group 35 known consumption somewhen between 1983 and 1988. One follow-up examination was possible in 5 cases after 16-24 years. The examinations included determination visual acuity, Amsler grid, slit lamp examination, perimetry, electro-oculography, electroretinography, optical coherence tomography fluorescein angiography.Complete disappearance...
Biodegradable collagen glycosaminoglycan matrices (CGM) have been introduced to glaucoma filtration surgery in order prevent scarring of the filtering bleb. In this retrospective case series, we describe a new surgical concept for treating symptomatic ocular hypotony following with mitomycin C by secondary subconjunctival implantation CGM.Depending on bleb morphology, CGM implant diameter 6 or 12 mm was placed subconjunctivally scleral flap eyes displaying (n=2) without (n=10) leakage....