Gerardo Gamez

ORCID: 0000-0002-8827-6647
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Mass Spectrometry Techniques and Applications
  • Analytical chemistry methods development
  • Analytical Chemistry and Chromatography
  • Heavy metals in environment
  • Adsorption and biosorption for pollutant removal
  • Advanced Chemical Sensor Technologies
  • Plasma Diagnostics and Applications
  • Ion-surface interactions and analysis
  • Analytical Chemistry and Sensors
  • Electrochemical Analysis and Applications
  • Quantum and electron transport phenomena
  • Laser-induced spectroscopy and plasma
  • Plasma Applications and Diagnostics
  • Spectroscopy Techniques in Biomedical and Chemical Research
  • Semiconductor materials and devices
  • Electrohydrodynamics and Fluid Dynamics
  • Physics of Superconductivity and Magnetism
  • Magnetic Field Sensors Techniques
  • Pesticide Residue Analysis and Safety
  • Identification and Quantification in Food
  • Isotope Analysis in Ecology
  • Phosphorus and nutrient management
  • Chromium effects and bioremediation
  • Nanoparticles: synthesis and applications
  • Gas Sensing Nanomaterials and Sensors

Texas Tech University
2015-2025

Lubbock Christian University
2015-2021

Universidad Nacional Autónoma de México
2017

Swiss Federal Laboratories for Materials Science and Technology
2010-2013

NTT Basic Research Laboratories
2012-2013

ETH Zurich
2008-2011

Indiana University Bloomington
2002-2008

Max Planck Institute for Solid State Research
2007

Max Planck Society
2007

The University of Texas at El Paso
1998-2003

A novel chemical ionization source for organic mass spectrometry is introduced. This new uses a glow discharge in the flowing afterglow mode generation of excited species and ions. The direct-current gas operated helium at atmospheric pressure; typical operating voltages currents are around 500 V 25 mA, respectively. generated by this pressure mixed with ambient air to generate reagent ions (mostly ionized water clusters NO+), which then used gaseous compounds. wide variety substances, both...

10.1021/ac800156y article EN Analytical Chemistry 2008-03-18

A novel method based on ultrasound-assisted EESI-MS has been developed and applied to rapidly detect the presence of melamine in raw milk, wheat gluten milk powder with no or minor sample pre-treatment; high throughput figures merit make it specially useful for screening levels well below current safety limit various food matrices.

10.1039/b818541g article EN Chemical Communications 2008-12-02

The flowing afterglow-atmospheric pressure glow discharge (APGD) ionization source described in part 1 of this study (in issue) is applied to the direct analysis condensed-phase samples. When either liquids or solids are exposed ionizing beam APGD, strong signals for molecular ions substances present on their surfaces can be detected without compromising integrity solid sample structure substrate. As was observed gas-phase compounds study, both polar and nonpolar ionized by mass...

10.1021/ac800210s article EN Analytical Chemistry 2008-03-18

A glow discharge using a solution as the cathode was investigated to add understanding of operating mechanism and characteristics such systems. The intensities vertical distributions emission from several analytes background species were observed compared with distribution Fe excitation OH rotational temperatures, well electrical characteristics. effects gap size, pH conductivity solution, applied current flow rate on these also studied. Detection limits for this system found be comparable...

10.1039/b503961d article EN Journal of Analytical Atomic Spectrometry 2005-01-01

The fractional quantum Hall (FQH) effect at filling factor ν = 5/2 has recently come under close scrutiny, as its ground state may possess quasi-particle excitations obeying nonabelian statistics, a property sought for topologically protected operations. However, microscopic origin remains unknown, and candidate model wave functions include those with undesirable abelian statistics. We report direct measurements of the electron spin polarization FQH using resistively detected nuclear...

10.1126/science.1216697 article EN Science 2012-01-27

A novel direct current glow discharge sustained in helium at atmospheric pressure has been developed. Current–voltage behavior and spectroscopic characteristics strongly suggest that the system operates regime, spite of high pressure. The diffuse extremely stable is typically operated within a voltage range 300–900 volts (in current-controlled mode) currents ranging over tens to hundreds milliamps. Spatially resolved measurements some selected species are presented. Rotational temperature...

10.1039/b607544d article EN Journal of Analytical Atomic Spectrometry 2006-01-01

Previously performed studies have shown that alfalfa shoot biomass can bind an appreciable amount of nickel(II) and chromium(III) ions from aqueous solution. Direct indirect approaches were applied to study the possible mechanisms involved in metal binding by biomass. The direct approach involves investigations metal-bound X-ray absorption spectroscopic analysis (XANES EXAFS). Results these suggest mostly occurs through coordination with oxygen ligands. Indirect consist chemical modification...

10.1021/es9804722 article EN Environmental Science & Technology 1998-12-01

Flowing afterglow atmospheric pressure glow discharge tandem mass spectrometry (APGD-MS/MS) is used for the analysis of trace amounts pesticides in fruit juices and on peel. The APGD source was rebuilt after Andrade et al. (Andrade al., Anal. Chem. 2008; 80: 2646-2653; 2654-2663) mounted onto a hybrid quadrupole time-of-flight spectrometer. Apple, cranberry, grape orange as well peel salad leaves were spiked with aqueous solutions containing alachlor, atrazine, carbendazim, carbofuran,...

10.1002/rcm.3677 article EN Rapid Communications in Mass Spectrometry 2008-08-12

Extractive electrospray ionization mass spectrometry (EESI-MS) was applied to rapid fingerprinting of various perfumes for quality classification. Unique EESI-MS fingerprints ten famous brands were obtained. This technique shown be applicable forgery detection on the example an authentic and a counterfeit 'Miss Dior' fragrance by Christian Dior. We believe that high throughput simplicity this sample-preparation-free method can advantageous in perfume industry, instance when online control.

10.1002/rcm.3584 article EN Rapid Communications in Mass Spectrometry 2008-05-21

Extractive electrospray ionization mass spectrometry is shown to allow real-time, in vivodrug monitoring and pharmacokinetic measurement a non-invasive, pain-free manner as demonstrated by the spectral of novel exhaled breath biomarker for valproic acid, medication used control epilepsy.

10.1039/c1cc10343a article EN Chemical Communications 2011-01-01

We report herein the use of Medicago sativa alfalfa shoot biomass for removal gold from aqueous solutions. The accumulation process involves reduction Au(III) to colloidal Au(0) and is shown increase at elevated temperatures lower pH. X-ray absorption spectroscopy (XAS) was used determine that gold(III) reduced form gold(0) colloids, which varied in size depending on pH initial solution. cluster radius 6.2 ± 1 Å 5 9.0 2. Our findings indicate essentially another layer atoms deposited onto...

10.1021/es991325m article EN Environmental Science & Technology 2000-09-09

Extractive electrospray ionization mass spectrometry (EESI-MS) for real-time monitoring of organic chemical reactions was demonstrated a well-established pharmaceutical process reaction and widely used acetylation in the presence nucleophilic catalyst, 4-dimethylaminopyridine (4-DMAP). EESI-MS provides information that allows us to determine optimum time terminating based on relative intensities precursors products. In addition, tandem spectrometric (MS/MS) analysis via permits on-line...

10.1002/rcm.3700 article EN Rapid Communications in Mass Spectrometry 2008-09-04

We report the observation of a fully developed fractional quantum Hall state at $\nu=5/2$ in GaAs/Al$_{x}$Ga$_{1-x}$As wells with mobility well below $10^{7}$\thinspace cm$^{2}$/Vs. This is achieved either by strong illumination or reducing barrier Al composition without illumination. explain both results terms screening ionized remote impurity (RI) potential nearby neutral shallow donors. Despite dramatic improvement transport features, energy gap $\Delta_{5/2}$ limited to rather small...

10.1103/physrevb.88.075308 article EN Physical Review B 2013-08-19

Glow discharge optical emission spectrometry (GDOES) allows fast and simultaneous multielemental analysis directly from solids depth profiling down to the nanometer scale, which is critical for thin-film (TF) characterization. Nevertheless, operating conditions best limits of detection (LODs) are compromised in lieu sputtering crater shapes resolution. In addition, transient signals ultra-TFs do not permit optimal sampling statistics bulk such that LODs further compromised. Furthermore,...

10.1021/acs.analchem.4c04718 article EN Analytical Chemistry 2025-01-21

The ion and electron populations of a glow discharge that uses an electrolytic solution as the cathode (an electrolyte-cathode or ELCAD) were investigated. This paper presents first determinations number density, ionization temperature, degrees in ELCAD. Spectroscopic techniques used to keep from perturbing plasma, range conditions was explored, two regions (the negative positive column) observed. By using Stark broadening hydrogen beta line, densities near 8.5 × 1014 cm−3 for 2.5 column...

10.1039/b517418j article EN Journal of Analytical Atomic Spectrometry 2006-01-01

Recent findings suggest that long-term exposure to diethyl phthalate (DEP), one of the widely used esters, can lead serious health problems. Most perfumes contain non-negligible amounts DEP. Rapid and sensitive detection DEP in is thus increasing importance. A novel procedure based on extractive electrospray ionization mass spectrometry (EESI-MS) has been developed for fast identification without need any sample pretreatment. The limit determination perfume was less than 100 ppb using tandem...

10.1021/ac801572d article EN Analytical Chemistry 2008-12-08

An instrument that combines near-field laser ablation at atmospheric pressure with an ion trap/time-of-flight mass spectrometer was developed. By coupling a UV into fiber tip of scanning optical microscope, craters much smaller than achievable conventional optics can in principle be obtained. Laser performed on samples such as DHB, anthracene, and pyrene. Desorbed neutral analytes are transferred from to trap, ionized, stored. After 10 ms, the ions extracted sensitive time-of-flight...

10.1021/ac8005044 article EN Analytical Chemistry 2008-07-12

Sticky subject: An N2 stream forms bubbles inside bulk viscous liquids, which create an aerosol sample through a microjetting mechanism (see picture). This is then analyzed by extractive electrospray ionization (EESI) mass spectrometry (MS). EESI-MS reveals the molecular composition of complex liquids and kinetics ongoing processes occurring in highly without any pretreatment. Detailed facts importance to specialist readers are published as "Supporting Information". Such documents...

10.1002/anie.200902360 article EN Angewandte Chemie International Edition 2009-09-25

Fluorescence spectroscopy and mass spectrometry have been extensively used for characterization of biomaterials, but usually separately. An instrument combining fluorescence Fourier-transform ion cyclotron resonance (FTICR-MS) has developed to explore both spectrometric behavior ions produced by electrospray ionization (ESI) in ultra high vacuum (<5 × 10−9 mbar). Using rhodamine 6G (R6G) as a sample, the was systematically characterized. Gas-phase spectral signal same population are detected...

10.1016/j.jasms.2009.05.011 article EN Journal of the American Society for Mass Spectrometry 2009-05-30

Flowing afterglow atmospheric pressure glow discharge mass spectrometry (FA-APGD-MS) was used to interrogate different polymer species such as biopolymers, synthetic homo- and co-polymers. The main advantages of FA-APGD-MS for samples include speed (<30 s per sample) analysis at pressures. Moreover, there are essentially no restrictions the kind sample that can be analyzed because deal with liquid solid (soluble or insoluble) bulk polymers granulates, irrespective their conductivity, without...

10.1039/b819560a article EN The Analyst 2009-01-01
Coming Soon ...