- Crystallization and Solubility Studies
- X-ray Diffraction in Crystallography
- Cardiac Imaging and Diagnostics
- Cardiovascular Function and Risk Factors
- Radiology practices and education
- Magnetism in coordination complexes
- Lanthanide and Transition Metal Complexes
- Advanced MRI Techniques and Applications
- Ultrasound in Clinical Applications
- Electron Spin Resonance Studies
- Radiation Dose and Imaging
- Educational Games and Gamification
- Simulation-Based Education in Healthcare
- Cardiovascular Disease and Adiposity
- Cardiac Valve Diseases and Treatments
- Advances in Oncology and Radiotherapy
- Surgical Simulation and Training
- Malaria Research and Control
- Augmented Reality Applications
- Mobile Learning in Education
- MRI in cancer diagnosis
Indiana University School of Medicine
2022-2024
University School
2024
Indiana University
2022-2024
Indiana University – Purdue University Indianapolis
2023-2024
Miami University
2016-2023
Brown University
2020-2023
University of Kentucky
2016-2018
Point of care ultrasound (POCUS) education has grown significantly over the past two decades. Like most curricular items, POCUS is siloed within individual graduate medical (GME) programs. The purpose this study was to evaluate effectiveness a shared GME curriculum between five programs at single institution. Post-graduate-year-1 (PGY-1) residents from emergency medicine (EM), family (FM), internal (IM), combined medicine-pediatrics (IM-Peds) and (EM-Peds) residency were enrolled in core...
Introduction: While gamification of point-of-care ultrasound (POCUS) is well received by learners, little known about the knowledge gained from material taught during these events. We set out to determine whether a POCUS event improved interpretation and clinical integration POCUS. Methods: This was prospective observational study fourth-year medical students who participated in 2.5-hour consisting eight objective-oriented stations. Each station had one three learning objectives associated...
Abstract Patients with end stage renal disease (ESRD) suffer high mortality from arrhythmias linked to fibrosis, but are contraindicated late gadolinium enhancement magnetic resonance imaging (MRI). We present a quantitative method for gadolinium-free cardiac fibrosis using magnetization transfer (MT) weighted MRI, and probe correlations widely used surrogate markers including structure contractile function in patients ESRD. In sub-group of who returned follow-up after one year, we examine...
Paramagnetic resonance studies (EPR, ESEEM, ENDOR, and NMR) of a series cobalt(II) bis-trispyrazolylmethane tetrafluoroborates are presented. The complexes studied include the parent, unsubstituted ligand (Tpm), two pyrazole-substituted derivatives (4Me 3,5-diMe), tris(1-pyrazolyl)ethane (Tpe), which includes methyl group on apical carbon atom. NMR ENDOR establish magnitude 1H hyperfine couplings, while ESEEM provides information coordinated 14N. data show that pyrazole 3-position is more...
<title>Abstract</title> Background Point of care ultrasound (POCUS) education has grown significantly over the past two decades. Like most curricular items, POCUS is siloed within individual graduate medical (GME) programs. The purpose this study was to evaluate effectiveness a shared GME curriculum between five programs at single institution. Methods Post-graduate-year-1 (PGY-1) residents from emergency medicine (EM), family (FM), internal (IM), combined medicine-pediatrics (IM-Peds) and...
Purpose: Cardiac stress blood biomarkers are typically correlated to hypertrophy or diastolic dysfunction but not fibrosis in chronic kidney disease (CKD). can be measured without gadolinium as elevated normalized signal difference (ΔS/S o ) between pairs of magnetization transfer (MT) weighted magnetic resonance (MRI) images. We used MT-MRI compare fibrosis, and strain rate CKD patients on hemodialysis (CKD5). Hypothesis: Biomarkers cardiac correlate with left ventricular (LV) hypertrophy,...
A comprehensive field- and temperature-dependent examination of nuclear magnetic resonance paramagnetic relaxation enhancements (PREs) for the constitutive protons [Co(Tpm)2][BF4]2 is presented. Data an apically substituted derivative clearly establish that bis-Tpm complexes Co(II) undergo Jahn-Teller dynamics about molecular threefold axis. PREs from parent Tpm complex were used to numerically extract electron times (T1e). The showed field-dependent behavior, with approximately 40% higher...
Introduction: Lung ultrasound (LUS) scoring of pulmonary edema severity has been proposed as a marker to track treatment response in acute heart failure (AHF), with hypothetical advantage detecting changes congestion more quickly than traditional markers response. We compared change LUS score contemporaneous daily weight, natriuretic peptides, subjective worst AHF symptom (WSS), and clinical/exam findings hospitalized patients from ED arrival discharge, determine which measure showed the...