C. A. Miller

ORCID: 0000-0003-1310-0310
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Nuclear Physics and Applications
  • Atomic and Subatomic Physics Research
  • Advanced NMR Techniques and Applications
  • Radiation Detection and Scintillator Technologies
  • Nuclear reactor physics and engineering
  • Radiation Therapy and Dosimetry
  • Crime Patterns and Interventions
  • Bullying, Victimization, and Aggression
  • Nuclear Materials and Properties
  • Research in Social Sciences
  • Ionosphere and magnetosphere dynamics
  • Intimate Partner and Family Violence
  • Particle accelerators and beam dynamics
  • Laser-Plasma Interactions and Diagnostics
  • High-Energy Particle Collisions Research
  • Sexual Assault and Victimization Studies
  • Medical Imaging Techniques and Applications
  • Superconducting Materials and Applications
  • Advanced Radiotherapy Techniques
  • Radiation Effects and Dosimetry
  • Advanced X-ray and CT Imaging
  • Quantum, superfluid, helium dynamics
  • Nuclear physics research studies
  • Quantum Chromodynamics and Particle Interactions
  • Magnetic confinement fusion research

Brain Tumour Charity
2024

National Institute of Standards and Technology
2022

California Polytechnic State University
2021

University of Michigan
2011-2020

Michigan United
2017

Bellevue College
2015

Georgia State University
2009-2014

TRIUMF
2010

University of Manitoba
1974-1979

The outbreak of the novel coronavirus disease, COVID-19 turned into a global pandemic in March 2020. During these unprecedented times, there is an increased demand medical and personal protective equipment (PPE). Since supplies may take long time to meet demand, reusing PPEs will help health care workers their response pandemic. To ensure safety well-being first responders, PPE needs be sterilized before reuse. In this review, we examine various sterilization techniques that can used...

10.1109/access.2020.3002886 article EN cc-by IEEE Access 2020-01-01

Polarisation asymmetries are measured for the hard exclusive leptoproduction of real photons from a longitudinally polarised hydrogen target. These arise deeply virtual Compton scattering and Bethe-Heitler processes. From data extracted two in azimuthal distribution produced about direction exchanged photon: $$ {\mathcal{A}_{\text{UL}}} with respect to target polarisation {\mathcal{A}_{\text{LL}}} product beam polarisations. Results both compared predictions generalised parton model. The sin...

10.1007/jhep06(2010)019 article EN cc-by-nc Journal of High Energy Physics 2010-06-01

This study sought to develop and validate an integrated laboratory paradigm of sexual aggression bystander intervention. Participants were a diverse community sample (54% African American) heterosexual males (N = 156) between 21 35 years age who recruited complete the with male friend ostensibly single, female reported strong dislike content in media. viewed sexually explicit or nonsexually film clip as part contrived media rating task made individual choices which show confederate....

10.1002/ab.21429 article EN Aggressive Behavior 2012-05-01

This study investigated the mediating effect of trait aggressivity on relation between agreeableness and alcohol-related aggression in a laboratory setting. Participants were 116 healthy male social drinkers 21 30 years age. Agreeableness measured using Big Five Inventory Buss-Perry Aggression Questionnaire, respectively. Following consumption an alcohol or no-alcohol control beverage, participants completed modified version Taylor Paradigm, which electric shocks received from administered...

10.1037/a0017727 article EN Experimental and Clinical Psychopharmacology 2009-12-01

10.1016/j.nimb.2015.11.007 article EN publisher-specific-oa Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2015-11-19

Abstract. The results of two radiation test campaigns on a low-cost commercial off-the-shelf magnetometer are presented. setup and the total ionization dose (TID) levels studied were designed to meet requirements mission land Europa. Based Europa Lander Science Definition Team report, instruments inside an aluminum vault at surface would need withstand TID up 300 krad(SI). In order evaluate performance PNI RM3100 magnetometer, nine separate sensors irradiated different facilities during...

10.5194/gi-9-499-2020 article EN cc-by Geoscientific instrumentation, methods and data systems 2020-12-23

10.1016/0029-554x(74)90434-0 article EN Nuclear Instruments and Methods 1974-02-01

10.1016/j.nima.2020.163598 article EN publisher-specific-oa Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2020-02-06

Purpose To develop and implement an efficient accurate commissioning procedure for small‐field static beam animal irradiation studies on MV research linear accelerator (Linatron‐M9) using radiochromic gel dosimetry. Materials The is a 9 linac with fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields 2 × , 1 0.5 . Relative dosimetry measurements performed, including profiles, percent depth dose (PDD) curves, divergence, relative output...

10.1002/mp.14685 article EN Medical Physics 2020-12-30

Dose rates, especially from photons and neutrons, inform safety procedures in any radioactive environment. A method for measuring dose rates both particles with one device will simplify current methods surveying fields. We have developed a technique using organic scintillators that is based on the definition of effective dose, extracted energy deposited detector. Using pulse shape discrimination, either neutrons or can be separated. Radiation weighting factors are applied to obtain...

10.1109/nssmic.2016.8069470 article EN 2016-10-01

Measurement of dose rates from both neutrons and photons inform radiation safety procedures in many areas nuclear technology. In previous work, we demonstrated a technique for using an organic scintillator to measure neutron photon mixed field with single detector cell. This method can be applied measurements wide variety applications, although different size detectors may required depending on the expected flux. The rate measured should not depend used, factors affect this dependence. work...

10.1109/nssmic.2017.8532804 article EN 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) 2017-10-01

Photon active interrogation offers solutions to many of the challenges with preventing proliferation concealed special nuclear material. A pulse shape discrimination capable organic scintillator based detection approach coupled use a conventional linac cost-effective technique. However, there are mitigating non-target emitted signals. In this investigation, background has been reduced through shielding and detector placement, photoneutrons have detected over background. Due pileup, neutrons...

10.1063/1.5127707 article EN AIP conference proceedings 2019-01-01

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some also rely on very specific attenuation correlations between response and dose, not scalable in size multiple required characterise mixed-particle fields. The research presented here serves as a proof-of-concept for method simultaneously measure dose rates from photons using particle discriminating organic scintillation detector without the need spectral...

10.1093/rpd/ncaa151 article EN Radiation Protection Dosimetry 2020-09-01

Purpose: To develop an instrument for measuring neutron and photon dose rates from mixed fields with a single device. Methods: Stilbene organic scintillators can be used to detect fast neutrons photons. was measure emission particle sources californium-252 (Cf-252) plutonium-beryllium (PuBe). Many source detector configurations were used, along varying amounts of shielding. Collected spectra analyzed using pulse shape discrimination software, separate interactions. With measured light output...

10.1118/1.4925852 article EN Medical Physics 2015-06-01

Main text The metrological equivalence of national measurement standards in the field photometry and radiometry is determined by a set key comparisons chosen organised Consultative Committee Photometry Radiometry (CCPR) Comité international des poids et mesures (CIPM), working closely with Regional Metrology Organisations (RMOs). In September 2009 CCPR decided that second round comparison K3 Luminous Intensity be commenced. National Research Council Canada (NRC) was to pilot this comparison....

10.1088/0026-1394/59/1a/02002 article EN Metrologia 2022-01-01

Abstract. The results of two radiation test campaigns on a low-cost commercial off-the-shelf magnetometer are presented. setup and the total ionization dose (TID) levels studied were designed to meet requirements mission land Europa. Based Europa Lander Science Definition Team report, instruments inside an aluminum vault at surface would need withstand TID up 300 krad(SI). In order evaluate performance PNI RM3100 magnetometer, nine separate sensors irradiated different facilities during...

10.5194/gi-2020-12 preprint EN cc-by 2020-05-25
Coming Soon ...